Measurement of blood pressure may be affected by an interaction between subject and observer based on gender

被引:0
|
作者
Millar, JA [1 ]
Accioly, JM [1 ]
机构
[1] UNIV PERTH,ROYAL PERTH HOSP,DEPT MED,PERTH,WA,AUSTRALIA
关键词
blood pressure; gender hypertension; sphygmomanometry; 'white-coat' effect;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Retrospective studies have suggested that blood pressure (BP) may be affected by a covert gender interaction between patient and observer, which is most marked for female patients and male observers, Such an effect could be one of the determinants of the 'white coat' response, We have assessed this interaction in a prospective study in 56 hospital outpatients (31 males, 25 females) in whom supine and erect BP and heart rate were measured by two male and two female subjects, and by an automatic sphygmomanometer when no persons were present. Supine systolic BP (SBP) was related to age, and fell progressively over three measurements, Absolute BP was less in females but the fall on repeated measurement was significantly greater than in males, When absolute BP was analysed by patient and observer sex, no significant interaction was present, BP measured by automatic sphygmomanometry was less than the value obtained clinically, Absolute BP showed no significant interaction with observer and patient sex, but the difference between machine and age-adjusted clinical measurements for SBP was significantly greater in female patients when BP was measured by male observers. However, this effect dissipated on repeated measurement. These data suggest that a transient gender interaction can contribute to the white-coat effect, especially in female patients when BP is measured by a male observer.
引用
收藏
页码:449 / 453
页数:5
相关论文
共 50 条
  • [1] The influence of the observer on blood pressure measurement
    Jardim, PC
    Bitencourt, AR
    Nascimento, LS
    Monego, ET
    Souza, WKSB
    JOURNAL OF HYPERTENSION, 2005, 23 : S286 - S286
  • [2] OBSERVER FACTORS IN MEASUREMENT OF BLOOD PRESSURE
    WILCOX, J
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1962, 179 (01): : 53 - &
  • [3] OBSERVER FACTORS IN THE MEASUREMENT OF BLOOD-PRESSURE
    WILCOX, J
    NURSING RESEARCH, 1961, 10 (01) : 4 - 17
  • [4] OBSERVER ERROR IN BLOOD-PRESSURE MEASUREMENT
    NEUFELD, PD
    JOHNSON, DL
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1986, 135 (06) : 633 - 637
  • [5] OBSERVER VARIATION IN MEASUREMENT OF ARTERIAL BLOOD PRESSURE
    EILERTSE.E
    HUMERFEL.S
    ACTA MEDICA SCANDINAVICA, 1968, 184 (03): : 145 - +
  • [6] BLOOD-PRESSURE MEASUREMENT WITHOUT OBSERVER VARIABILITY
    HOLLAND, WW
    WOLFF, HS
    JOURNAL OF PHYSIOLOGY-LONDON, 1961, 156 (01): : P2 - &
  • [7] Is blood pressure measurement influenced by the observer out of hospital?
    Pierin, A
    Moraes, KH
    Carvalho, VF
    Crasto, E
    Andreolli, RM
    Ignes, E
    Parisotto, P
    Mion, D
    Jacob, W
    JOURNAL OF HYPERTENSION, 2004, 22 : S141 - S141
  • [8] OBSERVER FACTORS IN THE MEASUREMENT OF BLOOD-PRESSURE - DISCUSSION
    SCHLOTFELDT, RM
    NURSING RESEARCH, 1961, 10 (01) : 18 - 20
  • [9] Importance of observer training for Indirect blood pressure measurement
    Netea, RT
    Gomez-Jardin, E
    Voermans, N
    Tromp, A
    Teirlinck, CJPM
    Thien, T
    JOURNAL OF HYPERTENSION, 1998, 16 : S274 - S274
  • [10] NOCTURNAL BLOOD-PRESSURE - MEASUREMENT IS SUBJECT TO BIAS
    STEWART, MJ
    BRITISH MEDICAL JOURNAL, 1994, 308 (6937): : 1163 - 1164