Statistical shape model-based planning organ-at-risk volume: application to pancreatic cancer patients

被引:6
|
作者
Nakamura, Mitsuhiro [1 ,2 ]
Nakao, Megumi [3 ]
Mukumoto, Nobutaka [2 ]
Ashida, Ryo [2 ]
Hirashima, Hideaki [2 ]
Yoshimura, Michio [2 ]
Mizowaki, Takashi [2 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Informat Technol & Med Engn, Human Hlth Sci,Div Med Phys, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, Kyoto 6068507, Japan
[3] Kyoto Univ, Grad Sch Informat, Dept Syst Sci, Kyoto 6068501, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 01期
关键词
Hausdorff distance; pancreatic cancer; statistical shape model; PRV; geometrical coverage probability; MANAGEMENT; TOXICITY; MOTION;
D O I
10.1088/1361-6560/abcd1b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. To introduce the concept of statistical shape model (SSM)-based planning organ-at-risk volume (sPRV) for pancreatic cancer patients. Methods. A total of 120 pancreatic cancer patients were enrolled in this study. After correcting inter-patient variations in the centroid position of the planning target volume (PTV), four different SSMs were constructed by registering a deformable template model to an individual model for the stomach and duodenum. The sPRV, which focused on the following different components of the inter-patient variations, was then created: Scenario A: shape, rotational angle, volume, and centroid position; Scenario B: shape, rotational angle, and volume; Scenario C: shape and rotational angle; and Scenario D: shape. The conventional PRV (cPRV) was created by adding an isotropic margin R (3-15 mm) to the mean shape model. The corresponding sPRV was created from the SSM until the volume difference between the cPRV and sPRV was less than 1%. Thereafter, we computed the overlapping volume between the PTV and cPRV (OLc) or sPRV (OLs) in each patient. OLs being larger than OLc implies that the local shape variations in the corresponding OAR close to the PTV were large. Therefore, OLs/OLc was calculated in each patient for each R-value, and the median value of OLs/OLc was regarded as a surrogate for plan quality for each R-value. Results. For R = 3 and 5 mm, OLs/OLc exceeded 1 for the stomach and duodenum in all scenarios, with a maximum OLs/OLc of 1.21. This indicates that smaller isotropic margins did not sufficiently account for the local shape changes close to the PTV. Conclusions. Our results indicated that, in contrast to conventional PRV, SSM-based PRVs, which account for local shape changes, would result in better dose sparing for the stomach and duodenum in pancreatic cancer patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Modeling daily changes in organ-at-risk anatomy in a cohort of pancreatic cancer patients
    Magallon-Baro, Alba
    Loi, Mauro
    Milder, Maaike T. W.
    Granton, Patrick V.
    Zolnay, Andras G.
    Nuyttens, Joost J.
    Hoogeman, Mischa S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 134 : 127 - 134
  • [2] Principal component analysis of daily changes in organ-at-risk anatomy in pancreatic cancer patients
    Magallon-Baro, A.
    Granton, P. V.
    Loi, M.
    Zolnay, A. G.
    Milder, M. T. W.
    Nuyttens, J. J.
    Hoogeman, M. S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S98 - S98
  • [3] A statistical shape model of the heart and its application to model-based segmentation
    Ordas, Sebastian
    Oubel, Estanislao
    Leta, Ruben
    Carreras, Francesc
    Frangi, Alejandro F.
    MEDICAL IMAGING 2007: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2007, 6511
  • [4] The effect of induction chemotherapy on tumor volume and organ-at-risk doses in patients with locally advanced oropharyngeal cancer
    Doornaert, Patricia
    Dahele, Max
    Verbakel, Wilko F. A. R.
    Bohoudi, Omar
    Slotman, Ben J.
    Langendijk, Johannes A.
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (02) : 269 - 274
  • [5] A Logistic Function-Based Model to Predict Organ-At-Risk (OAR) DVH in IMRT Treatment Planning
    Chen, S.
    Zhang, H.
    Zhang, B.
    D'Souza, W.
    MEDICAL PHYSICS, 2015, 42 (06) : 3339 - 3339
  • [6] Correlating Dose-Volume Histogram Results with Overlapping Volume of Organ-At-Risk and Planning Target Volume for Prostate IMRT
    Ma, T.
    Wang, I. Z.
    MEDICAL PHYSICS, 2014, 41 (06) : 349 - +
  • [7] Assessment of ovarian movement on consecutive pelvic MRI examinations in patients with gynaecological malignancies: what is the planning organ-at-risk volume for radiotherapy?
    Peters, N. H. G. M.
    Patterson, A. J.
    Horan, G.
    Gregory, D.
    Sala, E.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018): : 1407 - 1414
  • [8] Organ-At-Risk Segmentation in Brain MRI Using Model-Based Segmentation: Benefits of Deep Learning-Based Boundary Detectors
    Orasanu, Eliza
    Brosch, Tom
    Glide-Hurst, Carri
    Renisch, Steffen
    SHAPE IN MEDICAL IMAGING, SHAPEMI 2018, 2018, 11167 : 291 - 299
  • [9] Statistical shape model-based prediction of tibiofemoral cartilage
    Van Dijck, Christophe
    Wirix-Speetjens, Roel
    Jonkers, Ilse
    Vander Sloten, Jos
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2018, 21 (09) : 568 - 578
  • [10] Assessment of Clinical Impact On Treatment Planning of the Use of Deep-Learning Model for Organ-At-Risk Autosegmentation for Head and Neck Cancer
    Lucido, J.
    DeWees, T.
    Leavitt, T.
    Anand, A.
    Beltran, C.
    Brooke, M.
    Buroker, J.
    Foote, R.
    Foss, O.
    Hodge, T.
    Hughes, C.
    Hunzeker, A.
    Laack, N.
    Lenz, T.
    Morigami, M.
    Moseley, D.
    Patel, Y.
    Tryggestad, E.
    Undahl, L.
    Zverovitch, A.
    Patel, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E745 - E745