Immobilized aptamer paper spray ionization source for ion mobility spectrometry

被引:28
|
作者
Zargar, Tahereh [1 ]
Khayamian, Taghi [1 ]
Jafari, Mohammad T. [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
基金
美国国家科学基金会;
关键词
Paper spray ionization; Aptamer; Ion mobility spectrometry; THIN-FILM MICROEXTRACTION; ELECTROSPRAY-IONIZATION; MASS-SPECTROMETRY; CELLULOSE PAPER;
D O I
10.1016/j.jpba.2016.10.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective thin-film microextraction based on aptamer immobilized on cellulose paper was used as a paper spray ionization source for ion mobility spectrometry (PSI-IMS), for the first time. In this method, the paper is not only used as an ionization source but also it is utilized for the selective extraction of analyte, based on immobilized aptamer. This combination integrates both sample preparation and analyte ionization in a Whatman paper. To that end, an appropriate sample introduction system with a novel design was constructed for the paper spray ionization source. Using this system, a continuous solvent flow works as an elution and spray solvent simultaneously. In this method, analyte is adsorbed on a triangular paper with immobilized aptamer and then it is desorbed and ionized by elution solvent and applied high voltage on paper, respectively. The effects of different experimental parameters such as applied voltage, angle of paper tip, distance between paper tip and counter electrode, elution solvent type, and solvent flow rate were optimized. The proposed method was exhaustively validated in terms of sensitivity and reproducibility by analyzing the standard solutions of codeine and acetamiprid. The analytical results obtained are promising enough to ensure the use of immobilized aptamer paper-spray as both the extraction and ionization techniques in IMS for direct analysis of biomedicine. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 237
页数:6
相关论文
共 50 条
  • [1] Paper spray ionization with ion mobility spectrometry at ambient pressure
    Sukumar, H.
    Stone, J. A.
    Nishiyama, T.
    Yuan, C.
    Eiceman, G. A.
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2011, 14 (2-3) : 51 - 59
  • [2] Development of an ion mobility spectrometer with a paper spray ionization source
    Zhang Jingjing
    Jiang Jie
    Qiao Xiaolin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (06):
  • [3] Anticodeine aptamer immobilized on a Whatman cellulose paper for thin-film microextraction of codeine from urine followed by electrospray ionization ion mobility spectrometry
    Hashemian, Zahra
    Khayamian, Taghi
    Saraji, Mohammad
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (06) : 1615 - 1623
  • [4] Anticodeine aptamer immobilized on a Whatman cellulose paper for thin-film microextraction of codeine from urine followed by electrospray ionization ion mobility spectrometry
    Zahra Hashemian
    Taghi Khayamian
    Mohammad Saraji
    Analytical and Bioanalytical Chemistry, 2015, 407 : 1615 - 1623
  • [5] Porous graphite sheet spray ionization ion mobility spectrometry
    Zargar, Tahereh
    Jafari, Mohammad T.
    Khayamian, Taghi
    JOURNAL OF MASS SPECTROMETRY, 2018, 53 (11): : 1135 - 1142
  • [6] Rapid, in situ detection of cocaine residues based on paper spray ionization coupled with ion mobility spectrometry
    Li, Ming
    Zhang, Jingjing
    Jiang, Jie
    Zhang, Jing
    Gao, Jing
    Qiao, Xiaolin
    ANALYST, 2014, 139 (07) : 1687 - 1691
  • [7] Integration of paper spray ionization high-field asymmetric waveform ion mobility spectrometry for forensic applications
    Tsai, Chia-Wei
    Tipple, Christopher A.
    Yost, Richard A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (07) : 552 - 560
  • [8] Paper Spray Ionization Ion Mobility Mass Spectrometry of Sebum Classifies Biomarker Classes for the Diagnosis of Parkinson?s Disease
    Sarkar, Depanjan
    Sinclair, Eleanor
    Lim, Sze Hway
    Walton-Doyle, Caitlin
    Jafri, Kaneez
    Milne, Joy
    Vissers, Johannes P. C.
    Richardson, Keith
    Trivedi, Drupad K.
    Silverdale, Monty
    Barran, Perdita
    JACS AU, 2022, : 2013 - 2022
  • [9] Design and optimization of a corona discharge ionization source for ion mobility spectrometry
    Tabrizchi, M
    Khayamian, T
    Taj, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (06): : 2321 - 2328
  • [10] Spectroscopic characterization of a microplasma used as ionization source for ion mobility spectrometry
    Michels, Antje
    Tombrink, Sven
    Vautz, Wolfgang
    Miclea, Manuela
    Franzke, Joachim
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (11) : 1208 - 1215