摘要
This Study investigated the feasibility of an MRI protocol providing whole-body T-2* maps at 1.5 T. Seven healthy volunteers (mean age=30.1 +/- 3.7, three women and four men) and two patients (both male, 53 and 46 years old) affected by transfusion-dependent anemias participated in the study. Coronally oriented images of five Subsequent body levels were acquired using a fat-suppressed multiecho 2D gradient-echo sequence (12 echo times ranging from 4.8 to 76.3 ms were selected) and afterwards composed. Parametrical T-2* maps of the whole body were reconstructed on a pixel-by-pixel basis. For both, healthy volunteers and patients, representative T-2* values were computed from extended regions of interest (ROIs). Good-quality whole-body T-2* maps were computed in all volunteers and patients. In healthy volunteers, T-2* values were assessed in the cerebral white (58.5 +/- 4.2 ms) and gray (81.4 +/- 5.5 ms) matter, liver (34.3 +/- 7.0 ms), spleen (63.5 +/- 3.3 ms), kidneys (65.4 +/- 10.3 ms) and skeletal Muscles (similar to 30 ms). The liver presented faster relaxation rates in males as compared to females. One patient (serum ferritin concentration=927 mu g/dl) showed shortened T-2* values in liver (3.6 +/- 5.5 ins), spleen (3.1 +/- 4.8 ms), kidneys (11.1 +/- 7.1 ms) and muscles (25.1 +/- 3.4 ms). The second patient (serum ferritin concentration=346 mu g/dl) presented reduced T-2* values in liver (3.9 +/- 7.3 ms), spleen (20.1 +/- 9.8 ms) and kidneys (24.6 +/- 7.7 ms). The presented technique may find clinical application in the assessment of the iron burden in the entire body, and in monitoring of chelation therapies in patients treated with frequent blood transfusions. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:489 / 496
页数:8
相关论文
共 50 条
  • [1] MRI AND DETERMINATION OF T1 AND T2 OF SOLID POLYMERS USING A 1.5-T WHOLE-BODY IMAGER
    WIDMAIER, S
    JUNG, WI
    PFEFFER, K
    PFEFFER, M
    LUTZ, O
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (05) : 733 - 737
  • [2] T2 and T2* Mapping
    Welsch G.H.
    Hennig F.F.
    Krinner S.
    Trattnig S.
    [J]. Current Radiology Reports, 2 (8)
  • [3] Composite support system for 1.5 T whole-body MRI cryostat
    Suman, Navneet
    Kar, Soumen
    Siddiquee, Arshad Noor
    [J]. MATERIALS TODAY-PROCEEDINGS, 2022, 62 : 309 - 317
  • [4] Fast T1 mapping on a whole-body scanner
    Deichmann, R
    Hahn, D
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (01) : 206 - 209
  • [5] Quantitative Analysis of Supraspinatus Tendon Pathologies via T2/T2* Mapping Techniques with 1.5 T MRI
    Ece, Bunyamin
    Yigit, Hasan
    Ergun, Elif
    Koseoglu, Enver Necip
    Karavas, Erdal
    Aydin, Sonay
    Kosar, Pinar Nercis
    [J]. DIAGNOSTICS, 2023, 13 (15)
  • [6] COMPOSITIONAL ULTRASTRUCTURE OF THE NUCLEUS PULPOSUS AT 1.5T MRI: A COMPARATIVE STUDY OF T2 AND T2*MAPPING TECHNIQUES
    Dudek, A.
    Roemer, F. W.
    Welsch, G.
    Wimmer, M.
    Trattnig, S.
    Bohndorf, K.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2010, 18 : S190 - S190
  • [7] T-2 accuracy on a whole-body imager
    Foltz, WD
    Stainsby, JA
    Wright, GA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) : 759 - 768
  • [8] LOCALIZED NMR-SPECTROSCOPY WITH A 1.5 T WHOLE-BODY IMAGER USING CODEX
    JUNG, WI
    LUTZ, O
    MULLER, K
    PFEFFER, M
    [J]. ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1991, 46 (05): : 401 - 404
  • [9] T2 mapping and T2*imaging in heart failure
    Lota, A. S.
    Gatehouse, P. D.
    Mohiaddin, R. H.
    [J]. HEART FAILURE REVIEWS, 2017, 22 (04) : 431 - 440
  • [10] Robust myocardial T2 and T2* mapping at 3T
    Arshad Zaman
    David M Higgins
    Marc Kouwenhoven
    Ananth Kidambi
    John P Greenwood
    Sven Plein
    [J]. Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)