Non-contact vital-sign monitoring of patients undergoing haemodialysis treatment

被引:14
|
作者
Villarroel, Mauricio [1 ]
Jorge, Joao [1 ]
Meredith, David [2 ]
Sutherland, Sheera [2 ]
Pugh, Chris [3 ]
Tarassenko, Lionel [1 ]
机构
[1] Univ Oxford, Inst Biomed Engn, Dept Engn Sci, Oxford, England
[2] Oxford Univ Hosp Natl Hlth Serv Trust, Oxford Kidney Unit, Oxford, England
[3] Univ Oxford, Nuffield Dept Med, Oxford, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
HEART-RATE; TIME;
D O I
10.1038/s41598-020-75152-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A clinical study was designed to record a wide range of physiological values from patients undergoing haemodialysis treatment in the Renal Unit of the Churchill Hospital in Oxford. Video was recorded for a total of 84 dialysis sessions from 40 patients during the course of 1 year, comprising an overall video recording time of approximately 304.1 h. Reference values were provided by two devices in regular clinical use. The mean absolute error between the heart rate estimates from the camera and the average from two reference pulse oximeters (positioned at the finger and earlobe) was 2.8 beats/min for over 65% of the time the patient was stable. The mean absolute error between the respiratory rate estimates from the camera and the reference values (computed from the Electrocardiogram and a thoracic expansion sensor-chest belt) was 2.1 breaths/min for over 69% of the time for which the reference signals were valid. To increase the robustness of the algorithms, novel methods were devised for cancelling out aliased frequency components caused by the artificial light sources in the hospital, using auto-regressive modelling and pole cancellation. Maps of the spatial distribution of heart rate and respiratory rate information were developed from the coefficients of the auto-regressive models. Most of the periods for which the camera could not produce a reliable heart rate estimate lasted under 3 min, thus opening the possibility to monitor heart rate continuously in a clinical environment.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Non-contact vital-sign monitoring of patients undergoing haemodialysis treatment
    Mauricio Villarroel
    João Jorge
    David Meredith
    Sheera Sutherland
    Chris Pugh
    Lionel Tarassenko
    [J]. Scientific Reports, 10
  • [2] From Doppler to FMCW Radars for Non-Contact Vital-Sign Monitoring
    Munoz-Ferreras, Jose-Maria
    Wang, Jing
    Peng, Zhengyu
    Gomez-Garcia, Roberto
    Li, Changzhi
    [J]. 2018 2ND URSI ATLANTIC RADIO SCIENCE MEETING (AT-RASC), 2018,
  • [3] Non-Contact Vital-Sign Monitoring System for Premature Infants in Neonatal Intensive Care Units
    Foldesy, Peter
    Janoki, Imre
    Zarandy, Akos
    Pazmany, Peter
    [J]. ERCIM NEWS, 2020, (122): : 50 - 51
  • [4] Non-contact vital sign monitoring in the clinic
    Villarroel, Mauricio
    Jorge, Joao
    Pugh, Chris
    Tarassenko, Lionel
    [J]. 2017 12TH IEEE INTERNATIONAL CONFERENCE ON AUTOMATIC FACE AND GESTURE RECOGNITION (FG 2017), 2017, : 278 - 285
  • [5] Non-Contact Vital Sign Monitoring With a Metamaterial Surface
    Nguyen, Dat T.
    Zeng, Qihang
    Tian, Xi
    Ho, John S.
    [J]. 2022 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2022, : 37 - 39
  • [6] Non-contact and Real-time Pulse-based radar with Sensitivity Improvement for Vital-sign Monitoring
    Huang, Jian-Yu
    Hsu, Chia-Chin
    Chang, Chia-Hung
    Hu, Wei-Wen
    [J]. 2018 ASIA-PACIFIC MICROWAVE CONFERENCE PROCEEDINGS (APMC), 2018, : 812 - 814
  • [7] Vital-sign monitoring on the go
    Li, Changzhi
    [J]. NATURE ELECTRONICS, 2019, 2 (06) : 219 - 220
  • [8] Vital-sign monitoring on the go
    Changzhi Li
    [J]. Nature Electronics, 2019, 2 : 219 - 220
  • [9] A Novel Microwave Measurement Technique for Non-contact Vital Sign Monitoring
    Sinharay, Arijit
    Das, Rajat
    Seth, Sayan
    [J]. 2018 IEEE SENSORS, 2018, : 1515 - 1518
  • [10] Experimental 2.4 GHz CMOS RF front-ends for non-contact vital-sign sensing
    Wang, S.
    Chang, R. -H.
    [J]. ELECTRONICS LETTERS, 2015, 51 (23) : 1846 - 1847