Kinetics of factor IX activity differ from that of factor IX antigen in patients with haemophilia B receiving high-purity factor IX replacement

被引:0
|
作者
Liebman, HA
Rosenwald-Zuckerman, T
Retzios, A
Yasmin, S
Kasper, CK
机构
[1] Univ So Calif, Sch Med, Dept Med, Div Hematol, Los Angeles, CA 90033 USA
[2] Alpha Therapeut Corp, Los Angeles, CA USA
[3] Orthopaed Hosp, Hemophilia Ctr, Los Angeles, CA USA
关键词
haemophilia B; factor IX; kinetics;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pharmacokinetic studies in haemophilia B have found in vivo recovery of FIX (FIX) to be uniformly lower than the factor VIII recovery in haemophilia A. We hypothesized that this lower recovery could result from rapid binding to high-affinity receptors on platelets and endothelium. To test this hypothesis, we evaluated the kinetics of FIX activity and protein in haemophilia B patients. Twelve patients were enrolled in a double dosing, crossover study with two high-purity FIX concentrates, AlphaNine(R) SD and MonoNine(R). Subjects were given 40 U kg(-1) of FIX concentrate and blood samples were taken at 15, 30, and 60 min. A second infusion of 40 U kg(-1) was given after the 60 min blood sample and further blood samples removed at 15, 60, 120, and 360 min after the second dose. Patients were infused with the alternate concentrate at least 7 days later. Plasma samples were assayed for FIX activity by coagulation assay and antigen by RIA. FIX antigen in the infused concentrates was measured and quantified as mu g U-1. There was no difference between the two FIX concentrates (AlphaNine(R) vs. MonoNine(R)) in the initial (15 min) activity (57% +/- 1 19% vs. 53% +/- 1 12%) and antigen (62% +/- 1 16% vs. 55% +/- 1 19%) recoveries. Recoveries after the second FIX dose were not statistically different than those observed after the first FIX dose. In one patient, a doubling of the initial infusion dose did not increase FIX recovery after the second FIX dose. However, the recovery of FIX antigen was significantly greater than the recovery of FIX activity and the differences became more significant in the post-15 min samples. We calculated a ratio of plasma FIX antigen to FIX activity in mu g U-1. Average antigen to activity ratio increased from 5.8 +/- 1 1.9 mu g U-1 at 15 min to 7.1 +/- 1 2.2 mu g U-1 at 60 min. At 420 min the ratio increased to 9.3 +/- 1 2.4 mu g U-1. Although these studies failed to demonstrate a significant FIX receptor pool, they did demonstrate a phenomenon of progressive loss of biologic activity of the FIX protein after infusion of FIX concentrates.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 50 条
  • [1] Kinetics of factor IX activity differ from that of factor IX antigen in patients with hemophilia B
    RosenwaldZuckerman, T
    Yasmin, S
    Retzios, A
    Kasper, CK
    Leibman, HA
    [J]. BLOOD, 1995, 86 (10) : 3531 - 3531
  • [2] An open clinical study assessing the efficacy and safety of Factor IX Grifols®, a high-purity Factor IX concentrate, in patients with severe haemophilia B
    Lissitchkov, T.
    Matysiak, M.
    Zawilska, K.
    Gercheva, L.
    Antonov, A.
    Montanes, M.
    Paez, A.
    [J]. HAEMOPHILIA, 2010, 16 (02) : 240 - 246
  • [3] MONOCOMPONENT FACTOR-IX - A HIGH-PURITY FACTOR-IX CONCENTRATE FOR THE TREATMENT OF PATIENTS WITH HEMOPHILIA-B
    OATES, A
    HUGHES, E
    KUPCZYK, G
    MACGREGOR, A
    HERRINGTON, R
    [J]. THROMBOSIS AND HAEMOSTASIS, 1993, 69 (06) : 1284 - 1284
  • [4] Head-to-head comparison of the pharmacokinetic profiles of a high-purity factor IX concentrate (AlphaNine®) and a recombinant factor IX (BeneFIX®) in patients with severe haemophilia B
    Lissitchkov, T.
    Matysiak, M.
    Zavilska, K.
    Laguna, P.
    Gercheva, L.
    Antonov, A.
    Moret, A.
    Caunedo, P.
    Aznar, J. A.
    Woodward, M. K.
    Paez, A.
    [J]. HAEMOPHILIA, 2013, 19 (05) : 674 - 678
  • [5] Population pharmacokinetic modelling of factor IX activity after administration of recombinant factor IX in patients with haemophilia B
    Suzuki, A.
    Tomono, Y.
    Korth-Bradley, J. M.
    [J]. HAEMOPHILIA, 2016, 22 (05) : E359 - E366
  • [6] FACTOR-IX ACTIVITY AND FACTOR-IX ANTIGEN IN HEMOPHILIA B CARRIERS
    ELODI, S
    [J]. THROMBOSIS RESEARCH, 1975, 6 (01) : 39 - 51
  • [7] Pharmacokinetic study of a high-purity factor IX concentrate (Factor IX Grifols®) with a 6-month follow up in previously treated patients with severe haemophilia B
    Aznar, J. A.
    Cabrera, N.
    Matysiak, M.
    Zawilska, K.
    Gercheva, L.
    Antonov, A.
    Montanes, M.
    Paez, A. M.
    Lissitchkov, T.
    [J]. HAEMOPHILIA, 2009, 15 (06) : 1243 - 1248
  • [9] Measurement of activated factor IX in a high purity factor IX concentrate (Replenine®)
    Moola, Z
    O'Hara, H
    Crombie, D
    Talbot, J
    Winkelman, L
    [J]. THROMBOSIS AND HAEMOSTASIS, 1999, : 92 - 92
  • [10] A COAGULATION FACTOR-IX CONCENTRATE OF HIGH-PURITY
    KOENDERMAN, AHL
    VANDUREN, N
    MULLER, EJ
    BRANDS, L
    TERHART, HGJ
    HAKKENNES, CT
    KLEYN, GTOV
    HIEMSTRA, H
    OVER, J
    [J]. THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 1161 - 1161