Quantification by Ultrafiltration and Immunofixation Electrophoresis Testing for Monoclonal Serum Free Light Chains

被引:11
|
作者
Singh, Gurmukh [1 ]
Bollag, Roni [1 ]
机构
[1] Augusta Univ, Dept Pathol, Med Coll Georgia, Augusta, GA 30912 USA
关键词
plasma cell myeloma; light chain myeloma; ultrafiltration; immunofixation electrophoresis; monoclonal serum free light chains; multiple myeloma; GAMMOPATHIES; CRITERIA; MYELOMA;
D O I
10.1093/labmed/lmaa012
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: Measurement of monoclonal immunoglobulins is a reliable estimate of the plasma cell tumor mass. About 15% of plasma cell myelomas secrete light chains only. The concentration of serum free light chains is insufficient evidence of the monoclonal light chain burden. A sensitive quantitative estimate of serum free monodonal light chains could be useful for monitoring patients with light chain myeloma. We describe such an assay that does not require mass-spectrometry equipment or expertise. Methods: Serum specimens from patients with known light chain myelomas and controls were subjected to ultrafiltration through a membrane with pore size of 50 kDa. The filtrate was concentrated and tested by immunofixation electrophoresis. The relative area under the monoclonal peak, compared to that of the total involved light chain composition, was estimated by densitometric scanning of immunofixation gels. The proportion of the area occupied by the monoclonal peak in representative densitometric scans was used to arrive at the total serum concentration of the monoclonal serum free light chains. Results: Using an ultracentrifugation and concentration process, monoclonal serum free light chains were detectable, along with polyclonal light chains, in all 10 patients with active light chain myelomas. Monoclonal light chains were identified in serum specimens that did not reveal monoclonal light chains by conventional immunofixation electrophoresis. The limit of detection by this method was 1.0 mg/L of monoclonal serum free light chains. Conclusion: The method described here is simple enough to be implemented in academic medical center clinical laboratories and does not require special reagents, equipment, or expertise. Even though urine examination is the preferred method for the diagnosis of light chain plasma cell myelomas, measurement of the concentration of serum free light chains provides a convenient, albeit inadequate, way to monitor the course of disease. The method described here allows effective electrophoretic differentiation of monoclonal serum free light chain from polyclonal serum free light chains and provides a quantitation of the monocbnal serum free light chains in monitoring light chain monoclonal gammopathies.
引用
收藏
页码:592 / 600
页数:9
相关论文
共 50 条
  • [1] Multiple myeloma: Detection of free monoclonal light chains by modified immunofixation electrophoresis with antisera against free light chains
    Wilhite, Dorian
    Arfa, Ahmed
    Cotter, Thomas
    Savage, Natasha M.
    Bollag, Roni J.
    Singh, Gurmukh
    [J]. PRACTICAL LABORATORY MEDICINE, 2021, 27
  • [2] Excess Free Light Chains in Serum Immunofixation Electrophoresis: Attributes of a Distinctive Pattern
    Vani, Bharani
    Ritu, Aggarwal
    Praveen, Sharma
    Pankaj, Malhotra
    Minz, Ranjana
    [J]. INDIAN JOURNAL OF HEMATOLOGY AND BLOOD TRANSFUSION, 2018, 34 (04) : 632 - 635
  • [3] Excess Free Light Chains in Serum Immunofixation Electrophoresis: Attributes of a Distinctive Pattern
    Bharani Vani
    Aggarwal Ritu
    Sharma Praveen
    Malhotra Pankaj
    Ranjana Minz
    [J]. Indian Journal of Hematology and Blood Transfusion, 2018, 34 : 632 - 635
  • [4] A Study on Free Light Chain Assay and Serum Immunofixation Electrophoresis for the Diagnosis of Monoclonal Gammopathies
    Kuriakose, Eldho
    Cheppayil, Sumithra Narayanan Unni
    Narayanan, Subhakumari Kuzhikandathil
    Vasudevan, Anu
    [J]. INDIAN JOURNAL OF CLINICAL BIOCHEMISTRY, 2019, 34 (01) : 76 - 81
  • [5] Comparison of Serum Immunofixation Electrophoresis and Free Light Chain Assays in the Detection of Monoclonal Gammopathies
    Wood, Prescilla B.
    McElroy, Yolonda G.
    Stone, Marvin J.
    [J]. CLINICAL LYMPHOMA MYELOMA & LEUKEMIA, 2010, 10 (04): : 278 - 280
  • [6] A Study on Free Light Chain Assay and Serum Immunofixation Electrophoresis for the Diagnosis of Monoclonal Gammopathies
    Eldho Kuriakose
    Sumithra Narayanan Unni Cheppayil
    Subhakumari Kuzhikandathil Narayanan
    Anu Vasudevan
    [J]. Indian Journal of Clinical Biochemistry, 2019, 34 : 76 - 81
  • [7] Significance of serum free light chain estimation with detectable serum monoclonal protein on immunofixation electrophoresis.
    Mehta, Jayesh
    Stein, Regina
    Vickrey, Eric
    Resseguie, William
    Singhal, Seema
    [J]. BLOOD, 2006, 108 (11) : 351B - 351B
  • [8] Detection of monoclonal free light chains by immunofixation electrophoresis and isoelectric focusing - comparison with the quantitative method of determination
    Kusnierova, Pavlina
    Zeman, David
    Revendova, Kamila
    Dlouhy, Ondrej
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2020, 80 (07): : 556 - 561
  • [9] Isoelectric focusing followed by affinity immunoblotting to detect monoclonal free light chains in monoclonal gammopathies: Comparison with immunofixation electrophoresis and free light chain ratio
    Zeman, David
    Stork, Martin
    Svancarova, Lenka
    Borsky, Marek
    Pospisilova, Michaela
    Adam, Zdenek
    Benovska, Miroslava
    Pour, Ludek
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2024, 61 (04) : 291 - 302
  • [10] Serum free light chain assay reduces the need for serum and urine immunofixation electrophoresis in the evaluation of monoclonal gammopathy
    Fulton, Richard B.
    Fernando, Suran L.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2009, 46 : 407 - 412