On-line data fusion of pulse-echo ultrasound for testing composite materials

被引:0
|
作者
Noriega, VM [1 ]
Osegueda, RA [1 ]
Pierluissi, JH [1 ]
机构
[1] Univ Texas, Fast Ctr Struct Integr Aerosp Syst, El Paso, TX 79968 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An on-line fusion system for testing composite materials using ultrasound has been developed. The system offers a solution to the problem of obtaining false defects caused by uneven surfaces of composite materials. The A-scan signal is a bandpass signal. Finding the complex envelope of the bandpass signal helps track the thickness of the composite material as the transducer moves over it. Real-time digital signal processing is used to create a C-scan image by the Dempster-Shafer evidential reasoning method.
引用
收藏
页码:678 / 685
页数:8
相关论文
共 50 条
  • [1] Pulse-echo ultrasound attenuation tomography
    Martiartu, Naiara Korta
    Yolgunlu, Parisa Salemi
    Frenz, Martin
    Jaeger, Michael
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11):
  • [2] SonicPy: a suite of programs for ultrasound pulse-echo data acquisition and analysis
    Hrubiak, Rostislav
    Sturtevant, Blake T. T.
    HIGH PRESSURE RESEARCH, 2023, 43 (01) : 23 - 39
  • [3] Ultrasound pulse-echo imaging with an optimized propagator
    Huang, Lianjie
    Quan, Youli
    Li, Cuiping
    Duric, Neb
    Hanson, Kenneth M.
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 281 - +
  • [4] ULTRASOUND TRANSDUCERS FOR PULSE-ECHO MEDICAL IMAGING
    HUNT, JW
    ARDITI, M
    FOSTER, FS
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (08) : 453 - 481
  • [5] High-Order Pulse-Echo Ultrasound
    Hofmann, Urs A. T.
    Perez-Lopez, Sergio
    Estrada, Hector
    Razansky, Daniel
    PHYSICAL REVIEW APPLIED, 2022, 17 (05)
  • [6] INTERPOLATION SCAN CONVERSION IN PULSE-ECHO ULTRASOUND
    ROBINSON, DE
    KNIGHT, PC
    ULTRASONIC IMAGING, 1982, 4 (04) : 297 - 310
  • [7] Comparison of pulse-echo methods for testing concrete
    Krause, M
    Barmann, M
    Frielinghaus, R
    Kretzschmar, F
    Kroggel, O
    Langenberg, KJ
    Maierhofer, C
    Muller, W
    Neisecke, J
    Schickert, M
    Schmitz, V
    Wiggenhauser, H
    Wollbold, F
    NDT & E INTERNATIONAL, 1997, 30 (04) : 195 - 204
  • [8] Comparison of pulse-echo methods for testing concrete
    Krause, M.
    Baermann, M.
    Frielinghaus, R.
    Kretzschmar, F.
    Kroggel, O.
    Langenberg, K.J.
    Maierhofer, C.
    Mueller, W.
    Neisecke, J.
    Schickert, M.
    Schmitz, V.
    Wiggenhauser, H.
    Wollbold, F.
    NDT and E International, 1997, 30 (04): : 195 - 204
  • [9] PULSE-ECHO ULTRASOUND SPEED MEASUREMENTS - PROGRESS AND PROSPECTS
    ROBINSON, DE
    OPHIR, J
    WILSON, LS
    CHEN, CF
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (06): : 633 - 646
  • [10] DISTORTION CHARACTERIZATION FOR NONNORMAL INCIDENCE IN PULSE-ECHO ULTRASOUND
    OROFINO, DP
    PEDERSEN, PC
    IEEE 1989 ULTRASONICS SYMPOSIUM : PROCEEDINGS, VOLS 1 AND 2, 1989, : 1073 - 1076