An Innovative, Sensorless, Pulsatile, Continuous Flow Total Artificial Heart

被引:0
|
作者
Fukamachi, K. [1 ]
Horvath, D. J. [1 ]
Massiello, A. L. [1 ]
Fumoto, H. [1 ]
Horai, T. [1 ]
Rao, S. [1 ]
Golding, L. A. R. [1 ]
机构
[1] Cleveland Clin, Cleveland, OH 44106 USA
来源
关键词
D O I
10.1016/j.healun.2008.11.720
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
713
引用
收藏
页码:S313 / S314
页数:2
相关论文
共 50 条
  • [1] An innovative, sensorless, pulsatile, continuous-flow total artificial heart: Device design and initial in vitro study
    Fukamachi, Kiyotaka
    Horvath, David J.
    Massietto, Alex L.
    Fumoto, Hideyuki
    Horai, Tetsuya
    Rao, Santosh
    Golding, Leonard A. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (01): : 13 - 20
  • [2] Initial In Vivo Testing of a Self-Balancing Pulsatile Continuous Flow Total Artificial Heart
    Golding, L. A. R.
    Fukamachi, K.
    Horvath, D. J.
    Massiello, A. L.
    Fumoto, H.
    Arakawa, Y.
    Catanese, J.
    Chen, J. -F.
    Mielke, N.
    Horai, T.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S314 - S315
  • [3] Artificial pulse with a continuous-flow total artificial heart
    Khalil, H. A.
    Kerr, D. T.
    Schusterman, M. A., II
    Frazier, O. H.
    Radovancevic, B.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02): : S157 - S158
  • [4] Sensorless Suction Recognition in the Self-Regulating Cleveland Clinic Continuous-Flow Total Artificial Heart
    Horvath, David
    Karimov, Jamshid H.
    Byram, Nicole
    Kuban, Barry
    Golding, Leonard A. R.
    Moazami, Nader
    Fukamachi, Kiyotaka
    ASAIO JOURNAL, 2015, 61 (06) : 726 - 728
  • [5] PULSATILE VERSUS NON-PULSATILE FLOW IN THE DEVELOPMENT OF A TOTAL ARTIFICIAL-HEART (TAH)
    JACOBS, G
    HARASAKI, H
    SMITH, W
    KOIKE, S
    YADA, I
    GOLDING, L
    YOZU, R
    SATO, N
    OLSEN, E
    FUJIMOTO, L
    KIRALY, R
    NOSE, Y
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (08) : 533 - 534
  • [6] DEVELOPMENT OF A FLOW-TRANSFORMED PULSATILE TOTAL ARTIFICIAL-HEART FOR TOTAL IMPLANTATION
    IMACHI, K
    CHINZEI, T
    ABE, Y
    MABUCHI, K
    IMANISHI, K
    YONEZAWA, T
    SUZUKI, A
    ISOYAMA, T
    ATSUMI, K
    FUJIMASA, I
    ARTIFICIAL ORGANS, 1992, 16 (03) : 308 - 313
  • [7] The Continuous Flow Total Artificial Heart in Clinical Practice
    Macku, David
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 318 - 321
  • [8] Hybrid Continuous-Flow Total Artificial Heart
    Fox, Carson
    Chopski, Steven
    Murad, Nohra
    Allaire, Paul
    Mentzer, Robert, Jr.
    Rossano, Joseph
    Arabia, Francisco
    Throckmorton, Amy
    ARTIFICIAL ORGANS, 2018, 42 (05) : 500 - 509
  • [9] Characterization of a pulsatile rotary total artificial heart
    Jurney, Patrick L.
    Glynn, Jeremy J.
    Dykan, Igor V.
    Hagen, Matthew W.
    Kaul, Sanjiv
    Wampler, Richard K.
    Hinds, Monica T.
    Giraud, George D.
    ARTIFICIAL ORGANS, 2021, 45 (02) : 135 - 142
  • [10] Drive optimisation of a pulsatile Total Artificial Heart
    Pohlmann, Andre
    Lessmann, Marc
    Finocchiaro, Thomas
    Fritschi, Andreas
    Steinseifer, Ulrich
    Schmitz-Rode, Thomas
    Hameyer, Kay
    ARCHIVES OF ELECTRICAL ENGINEERING, 2011, 60 (02) : 169 - 178