Design of Bidirectional Security System for Intravenous Drip Infusion with Hybrid Communication

被引:1
|
作者
Chen, Chin-Cheng [1 ,2 ]
Chen, Fu-Hsien [3 ]
Hsu, Chun-Liang [4 ]
Chuang, Wei-Ching [5 ]
Lee, Chun-Ying [5 ]
Lee, Chun-Hsien [5 ]
Ho, Chi-Ting [6 ]
Ma, Yi [7 ]
Wu, Tung-Lung [7 ]
机构
[1] Jimei Univ, Informat & Engn Coll, Xiamen 361021, Peoples R China
[2] Chaoyang Univ Technol, Dept Aeronaut Engn, Taichung 413, Taiwan
[3] Lunghwa Univ Sci & Technol, Dept Elect Engn, Taoyuan 333, Taiwan
[4] St Johns Univ, Dept Elect Engn, New Taipei 251, Taiwan
[5] Natl Formosa Univ, Inst Electroopt & Mat Sci, Huwei Township 632, Yunlin, Taiwan
[6] Natl Formosa Univ, Dept Mech Design Engn, Huwei Township 632, Yunlin, Taiwan
[7] Longyan Univ, Sch Math & Informat Engn, Longyan, Fujian, Peoples R China
关键词
intravenous drip; QR code; wireless sensor networks; load cell; remaining quantity;
D O I
10.18494/SAM.2020.2684
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Automation systems arc widely applied in many fields such as manufacturing, warehousing, machinery, power management, and smart living spaces. In this study, a bidirectional security system was designed and applied to intravenous (IV) infusion for wards in hospitals. The system comprised a high-resolution gravity sensor, a 2.4 GHz XBee wireless sensor network communication module, and a drip-quantity-detecting control box with a HOTEC Corp. MCU HT66F70A core microprocessor to achieve automated management in the medical field. Toward achieving sustainability in our medical environment and computer science technology, we adopted data transformation, an Internet of Things (IoT) wireless communication and sensor network, and an app to construct the bidirectional security system for IV infusion. The main aims of the proposed method in this study were as follows: (I) to invent a reliable method to detect the remaining quantity of a patient's drip infusion using a gravity sensor so as to prevent the dangerous condition of blood flowing backward or air intruding into the vein as well as to decrease the burden on nursing staff in wards, and (2) to avoid medical disputes due to the incorrect infusion from drips, the autorecognition of patients using scanning QR code technology was applied in the medical management system. The outcome of the study was proved successful and has won many important national invention contests.
引用
收藏
页码:2709 / 2728
页数:20
相关论文
共 50 条
  • [1] DRIP INFUSION INTRAVENOUS CHOLANGIOGRAPHY
    MARGOLIN, FR
    OBATA, W
    RADIOLOGIA CLINICA ET BIOLOGICA, 1968, 37 (06) : 353 - &
  • [2] EXPERIENCE WITH INTRAVENOUS DRIP INFUSION OF AMIKACIN
    ISHII, T
    KISHIMOTO, S
    JAPANESE JOURNAL OF ANTIBIOTICS, 1981, 34 (07): : 1063 - 1070
  • [3] APPLICATION OF AMIKACIN BY INTRAVENOUS DRIP INFUSION
    YAMAMOTO, K
    SAKATA, K
    NIWA, A
    IMURA, M
    NAKAMURA, H
    OKUMOTO, T
    TAKATANI, O
    JAPANESE JOURNAL OF ANTIBIOTICS, 1981, 34 (03): : 412 - 418
  • [4] THE INVIVO ACTIVITY OF TOBRAMYCIN INTRAVENOUS DRIP INFUSION
    SAITO, A
    JAPANESE JOURNAL OF ANTIBIOTICS, 1980, 33 (10): : 989 - 993
  • [5] EXPERIENCE WITH INTRAVENOUS DRIP INFUSION OF AMIKACIN IN UROLOGICAL FIELD
    MURAHASHI, I
    TOYODA, A
    TAKASAKI, E
    JAPANESE JOURNAL OF ANTIBIOTICS, 1981, 34 (02): : 133 - 139
  • [6] SINGLE BOLUS VERSUS DRIP INFUSION FOR INTRAVENOUS CHOLANGIOGRAPHY
    ESHCHAR, J
    SHYKYAR, S
    PAJEWSKI, M
    CLINICAL RADIOLOGY, 1976, 27 (02) : 245 - 247
  • [7] Design and Implementation of an Intravenous Infusion Control and Monitoring System
    Caya, Meo Vincent
    Cosindad, Marvin U.
    Marcelo, Nicanor I., Jr.
    Santos, Jose Nicolas M.
    Torres, Jumelyn L.
    2019 4TH IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - ASIA (IEEE ICCE-ASIA 2019), 2019, : 68 - 72
  • [8] IMPORTANCE OF THE MODE OF INTRAVENOUS ADMINISTRATION ON CEPHOTAXIME CONCENTRATION IN BILE - A COMPARISON OF BOLUS, DRIP INFUSION AND BOLUS PLUS DRIP INFUSION
    MIGLIOLI, PA
    TEDESCHI, U
    CHEMOTHERAPY, 1988, 34 (05) : 380 - 384
  • [9] A new drip infusion monitoring system
    Ogawa, Hidekuni
    Yonezawa, Yoshiharu
    Maki, Hiromichi
    Hahn, Allen W.
    Caldwell, W. Morton
    Biomedical Sciences Instrumentation, 2010, 46
  • [10] EFFECT OF A DRIP INFUSION OF INTRAVENOUS DILTIAZEM ON SEVERE SYSTEMIC HYPERTENSION
    ONOYAMA, K
    OMAE, T
    IIMURA, O
    YOSHINAGA, K
    INAGAKI, Y
    TAKEDA, T
    KIKUCHI, K
    CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 1988, 43 (03): : 361 - 368