Pentacam Scheimpflug Tomography Findings in Chinese Patients With Different Corneal Diameters

被引:9
|
作者
Ding, Lan [1 ]
Wang, Jifang [1 ]
Niu, Lingling [1 ]
Shi, Wanru [1 ]
Qian, Yishan [1 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, NHC Key Lab Myopia, Shanghai, Peoples R China
关键词
OCULAR RESPONSE ANALYZER; FORME-FRUSTE KERATOCONUS; PARAMETERS; EYES; ELEVATION; ECTASIA;
D O I
10.3928/1081597X-20200730-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the Pentacam (Ocutus Optikgerate) Scheimpflug tomography findings in Chinese patients with different corneal diameters. METHODS: This prospective cross-sectional study included candidates for correction of myopia with normal tomography (ABCD keratoconus grading system, stage 0). The participants were grouped according to their horizontal corneal diameters. Pentacam ectasia detection indices were compared between different corneal diameter-based groups. RESULTS: A total of 643 eyes were included (corneal. diameter <= 11 mm, n = 206; 11 to 12 mm, n = 219; >= 12 mm, n = 218). The corneal powers and the thinnest pachymetry were negatively correlated with corneal diameter (linear regression analysis, P < .001). However, the corneal astigmatism was positively correlated with corneal diameter (R-2 = 0.03, P < .001). Both the front (FE) and back (BE) elevations were negatively correlated with corneal diameter (FE: R-2 = 0.027, P < .001; BE: R-2 = 0.274, P < .001). The three pachymetric progression indices (PPI) (minimum, maximum, and average) were negatively correlated with corneal diameter (PPImin: R-2 = 0.164, P < .001; PPImax: R-2 =0.06, P < .001; PPlavg: R-2 = 0.158, P < .001). The maximum Ambrosio's relational thickness (ARTmax) also was positively correlated with corneal diameter (R-2 = 0.031, P < .001). Five normalized indices were negatively correlated with corneal diameter (deviation of normality of the front elevation [Df]: R-2 = 0.122, P < .001; deviation of normality of the back elevation [Db]: R-2 = 0.47, P < .001; deviation of normality of pachymetric progression [Dp]: R-2 = 0.159, P < .001; deviation of normality of relational thickness [Da]: R-2 = .031, P < .001; Belin/Ambrosio Enhanced Ectasia display: R-2 = 0.32, P < .0011 and Dt was positively correlated with corneal diameter (R-2 = 0.015, P = .002). Additionally, it was noted that corneal diameter had the greatest influence on Db, Belin/Ambrosio Enhanced Ectasia display (BAD-D), and BE. CONCLUSIONS: Corneal diameter has an influence on the BAD parameters, especially Db, BAD-D, and BE, and therefore should be incorporated as an additional variable in BAD analysis. The analytical dimensions should be individualized for eyes with individual corneal diameter.
引用
收藏
页码:688 / +
页数:11
相关论文
共 50 条
  • [1] Pentacam and Corvis ST findings in myopic Chinese patients with different corneal diameters in Singapore
    Lim, Elizabeth Wen Ling
    Htoon, Hla Myint
    Tan, Peng Yi
    Ang, Marcus
    Mehta, Jodhbir S.
    Lim, Li
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 5)
  • [2] Performance of Scheimpflug-based tomography (Pentacam) in patients with and without corneal diseases
    Habeeb, M.
    Meester-Smoor, M. A.
    Geerards, A. J. M.
    Klaver, C. C. W.
    Ramdas, W. D.
    van Dooren, B. T. H.
    ACTA OPHTHALMOLOGICA, 2019, 97 : 4 - 4
  • [3] Corneal changes in time in normal and keratoconic patients assessed by Pentacam Scheimpflug tomography
    Ximena Minguez, Natalia
    Ruisenor Vazquez, Pablo Raul
    David Galletti, Jonatan
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfortner, Tomas
    Gaston Galletti, Jeremias
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [4] Corneal Asymmetry Analysis by Pentacam Scheimpflug Tomography for Keratoconus Diagnosis
    Galletti, Jonatan D.
    Ruisenor Vazquez, Pablo R.
    Minguez, Natalia
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfoertner, Tomas
    Galletti, Jeremias G.
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (02) : 116 - +
  • [5] Keratoconus detection by corneal asymmetry analysis with Pentacam Scheimpflug tomography
    David Galletti, Jonatan
    Ruisenor Vazquez, Pablo Raul
    Ximena Minguez, Natalia
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfortner, Tomas
    Gaston Galletti, Jeremias
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [6] Pentacam Scheimpflug Tomography Findings in Topographically Normal Patients and Subclinical Keratoconus Cases
    Ruiseor Vazquez, Pablo R.
    David Galletti, Jonatan
    Minguez, Natalia
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfortner, Tomas
    Gaston Galletti, Jeremias
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (01) : 32 - 40
  • [7] Pentacam Scheimpflug Tomography Findings in Topographically Normal Patients and Subclinical Keratoconus Cases
    Jia, Yan
    Zhu, Haobin
    Zhou, Jibo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (01) : 209 - 209
  • [8] Effect of white-to-white corneal diameter on biomechanical indices assessed by Pentacam Scheimpflug corneal tomography and corneal visualization Scheimpflug technology
    Lin, Qinghong
    Shen, Zhengwei
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (05) : 1537 - 1543
  • [9] Effect of white-to-white corneal diameter on biomechanical indices assessed by Pentacam Scheimpflug corneal tomography and corneal visualization Scheimpflug technology
    Qinghong Lin
    Zhengwei Shen
    International Ophthalmology, 2022, 42 : 1537 - 1543
  • [10] Pentacam Scheimpflug Evaluation of Corneal Volume After LASIK
    Diniz, Camila M. Gadelha P.
    Hazarbassanov, Rossen M.
    Yamazaki, Ester
    Murata, Celina
    Mallmann, Felipe
    Campos, Mauro
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (08) : 600 - 604