X-ray irradiation of silicon detectors

被引:0
|
作者
Chmill, V. [1 ]
机构
[1] Royal Inst Technol, AlbaNova, Dept Phys, SE-10691 Stockholm, Sweden
关键词
X-ray; silicon; detector; radiation hardness; voltage training;
D O I
10.1016/j.nima.2006.07.057
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon pad detectors were irradiated with a 30 kVp X-ray energy spectrum and the change in capacity and dark current was measured as a function of radiation dose and restoring time. After irradiation of the detectors the parameters were monitored and the time to get back to the baseline before irradiation was measured. The relaxation process of the detector functionality (the recovery of the characteristics) was observed with bias voltage applied to the detectors. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:722 / 726
页数:5
相关论文
共 50 条
  • [1] Amorphous silicon X-ray detectors
    Hoheisel, M
    Arques, M
    Chabbal, J
    Chaussat, C
    Ducourant, T
    Hahm, G
    Horbaschek, H
    Schulz, R
    Spahn, M
    [J]. JOURNAL OF NON-CRYSTALLINE SOLIDS, 1998, 227 : 1300 - 1305
  • [2] Silicon Absolute X-Ray Detectors
    Seely, John F.
    Korde, Raj
    Sprunck, Jacob
    Medjoubi, Kadda
    Hustache, Stephanie
    [J]. SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 842 - +
  • [3] Advances in silicon carbide X-ray detectors
    Bertuccio, Giuseppe
    Caccia, Stefano
    Puglisi, Donatella
    Macera, Daniele
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 193 - 196
  • [4] The spectral response of silicon X-ray detectors
    Eggert, T.
    Boslau, O.
    Kemmer, J.
    Pahke, A.
    Wiest, F.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 1 - 11
  • [5] High efficiency silicon X-ray detectors
    Tull, CR
    Iwanczyk, JS
    Patt, BE
    Barkan, S
    Feng, L
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1803 - 1807
  • [6] High efficiency silicon X-ray detectors
    Tull, CR
    Iwanczyk, JS
    Patt, BE
    Barkan, S
    Feng, L
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1341 - 1345
  • [7] X-ray silicon detectors for measuring hard X-ray radiation damage effects
    Wagner, D
    Halmagean, E
    Loukas, D
    Misiakos, K
    Tsoi, E
    Veron, A
    Ohanisian, M
    [J]. HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 : 296 - 304
  • [8] Multichannel silicon drift detectors for X-ray spectroscopy
    Lechner, P
    Buttler, W
    Fiorini, C
    Hartmann, R
    Kemmer, J
    Krause, N
    Leutenegger, P
    Longoni, A
    Soltau, H
    Stötter, D
    Stötter, R
    Strüder, L
    Weber, U
    [J]. X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 592 - 599
  • [9] Improved X-ray silicon detectors for medical applications
    Halmagean, E
    Tsoi, E
    Misiakos, K
    Ohanisian, M
    Veron, A
    Cimpoca, V
    Lazarovici, D
    [J]. CAS '96 PROCEEDINGS - 1996 INTERNATIONAL SEMICONDUCTOR CONFERENCE, 19TH EDITION, VOLS 1 AND 2, 1996, : 653 - 656
  • [10] SILICON SURFACE BARRIER DETECTORS FOR X-RAY SPECTROSCOPY
    KALBITZER, S
    MELZER, W
    STUMPFI, W
    [J]. ZEITSCHRIFT FUR ANGEWANDTE PHYSIK, 1968, 24 (04): : 181 - +