Clinical Value of Tc99m-MIBI SPECT/CT Versus 4D-CT or US in Management of Patients With Hyperparathyroidism

被引:36
|
作者
Kedarisetty, Suraj [1 ]
Fundakowski, Christopher [1 ]
Ramakrishnan, Karthika [2 ]
Dadparvar, Simin [2 ]
机构
[1] Temple Univ, Sch Med, Lewis Katz Sch Med, Dept Otolaryngol Head & Neck Surg, Philadelphia, PA 19122 USA
[2] Temple Univ, Sch Med, Lewis Katz Sch Med, Dept Radiol,Div Nucl Med & Mol Imaging, Philadelphia, PA 19122 USA
关键词
hyperparathyroidism; parathyroid adenoma; Tc99m-MIBI; SPECT; CT; 4D-CT; ultrasound; MINIMALLY INVASIVE PARATHYROIDECTOMY; HORMONE LEVEL; 4D MRI; LOCALIZATION; SESTAMIBI; ADENOMAS; SCINTIGRAPHY; ULTRASONOGRAPHY; HYPERCALCEMIA; SENSITIVITY;
D O I
10.1177/0145561319828668
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Localization of parathyroid adenomas for treatment of primary hyperparathyroidism can be challenging. This retrospective study compared single-photon emission computed tomography/computed tomography (SPECT/CT), 4D-CT, and US studies in detection of adenomas prior to surgery. A retrospective chart review was performed on all consecutive patients with parathyroid adenoma presenting to an urban tertiary care medical center. A total of 58 patients (45 female, 13 male) underwent surgery for parathyroid adenoma. Patients aged 28 to 80 years (mean: 58.8) with parathyroid hormone levels ranging from 42 to 424 pg/mL (mean: 168). All patients underwent preoperative SPECT/CT with 20 mCi technetium-99m MIBI (Tc-99m-MIBI). Fifty-three patients had additional US imaging and 14 patients had 4D-CT scans. Additionally, 34 patients had injection of 20 mCi Tc-99m-MIBI on the day of surgery. Pathological correlation was performed. Comparing SPECT/CT versus 4D-CT resulted in sensitivity (77% vs 80%), specificity (71% vs 75%), and accuracy (77% vs 79%). Ultrasound was less sensitive with similar specificity (44%, 86%, respectively). Combination of SPECT/CT and 4D-CT increased sensitivity to 88%, specificity to 100%, and accuracy to 89%. Combining SPECT/CT with US resulted in sensitivity of 85%, specificity of 83%, and accuracy of 85%. Intraoperative localization substantially improved in patients who received preoperative injections. The SPECT/CT remains the best imaging modality for preoperative localization of parathyroid adenomas with high sensitivity. Combining SPECT/CT with US resulted in increased sensitivity and accuracy. For suspicion of ectopic cases or suspicion of unidentifiable adenoma with negative scintigraphy, addition of 4D-CT is recommended. Intraoperative localization and adjunctive imaging may improve surgical management of patients with hyperparathyroidism.
引用
收藏
页码:149 / 157
页数:9
相关论文
共 50 条
  • [1] Value of Tc-99m-MIBI-SPECT and SPECT/CT-Fusion in Addition to Planar Tc-MIBI Scintigraphy in Hyperparathyroidism
    Zaplatnikov, K.
    Wiedemann, W.
    Soukhov, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S371 - S371
  • [2] The value of gammagraphy using Tc99m-MIBI before parathyroidectomy in patients with secondary hyperparathyroidism
    Martín, F
    Sarró, F
    Verdú, J
    Martínez, A
    NEFROLOGIA, 2001, 21 (02): : 221 - 222
  • [3] The role of SPECT Tc99m-MIBI parathyroid scintigraphy in the preoperative evaluation of patients with primary hyperparathyroidism
    Oskouie, S. S. Dabiri
    Emami, S.
    Dabiri, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S370 - S370
  • [4] The value of SPECT/ CT Technetium-99m-MIBI in primary hyperparathyroidism
    Al-Janabi, Mazin
    D'Sa, Anthony
    Corcoran, Ben
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [5] Tc-99m-MIBI-SPECT and SPECT/CT/MRT-Fusion in Addition to Planar Scintigraphy in Patients with Hyperparathyroidism
    Zaplatnikov, K.
    Wiedemann, W.
    Soukhov, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S274 - S274
  • [6] Technetium-99m-MIBI SPECT/CT in primary hyperparathyroidism
    Krausz, Y
    Bettman, L
    Guralnik, L
    Yosilevsky, G
    Keidar, Z
    Bar-Shalom, R
    Even-Sapir, E
    Chisin, R
    Israel, O
    WORLD JOURNAL OF SURGERY, 2006, 30 (01) : 76 - 83
  • [7] Technetium-99m-MIBI SPECT/CT in Primary Hyperparathyroidism
    Yodphat Krausz
    Lise Bettman
    Luda Guralnik
    Galina Yosilevsky
    Zohar Keidar
    Rachel Bar-Shalom
    Einat Even-Sapir
    Roland Chisin
    Ora Israel
    World Journal of Surgery, 2006, 30 : 76 - 83
  • [8] Comparison of Tc99m-MIBI and TL201/Tc99m substraction scintigraphy in patients with hyperparathyroidism
    Uslu, H
    Yildirim, M
    Varoglu, E
    Bayrakdar, R
    Akçay, F
    Ünüvar, N
    Demirci, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1215 - 1215
  • [9] Diagnostic value of preoperative early SPECT with Tc-99m pertechnetate and Tc-99m MIBI (early MIBI/Tc-99m SPECT) in primary hyperparathyroidism
    Shafipour, H
    Onsel, C
    Aksoy, F
    Kabasakal, L
    Sayman, H
    Sonmezoglu, K
    Kanmaz, B
    Carikci, O
    Dogan, I
    Uslu, I
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S430 - S430
  • [10] 18F-Fluorocholine PET/CT, Tc-99m-MIBI and TC-99m-MDP SPECT/CT in Tertiary Hyperparathyroidism with Renal Osteodystrophy
    Ferrari, Cristina
    Lavelli, Valentina
    Santo, Giulia
    Frugis, Maria Teresa
    Iuele, Francesca
    Rubini, Giuseppe
    Sardaro, Angela
    DIAGNOSTICS, 2020, 10 (10)