Alloying titanium and tantalum by cold crucible levitation melting (CCLM) furnace

被引:70
|
作者
Morita, A
Fukui, H
Tadano, H
Hayashi, S
Hasegawa, J
Niinomi, M
机构
[1] Fuji Elect Furnace Co Ltd, Suzuka, Mie 5138633, Japan
[2] Aichi Gakuin Univ, Sch Dent, Dept Dent Mat, Chikusa Ku, Nagoya, Aichi 464, Japan
[3] Toyohashi Univ Technol, Dept Prod Syst Engn, Toyohashi, Aichi 4418550, Japan
关键词
biomedical titanium alloys; alloying titanium and tantalum; cold crucible levitation melting; CCLM; making an alloy of base metals; single melting (no re-melting) process;
D O I
10.1016/S0921-5093(99)00668-1
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Recently, titanium alloys have been studied as implant materials for dental and orthopedic surgery. Titanium alloys have distinguished characteristics of biocompatibility, corrosion resistance and mechanical properties. Having non-poisonous character to a living body, Ta, Zr and Nb have been used for addition to titanium alloys, which are free of vanadium and aluminum. It is well-known that titanium and tantalum are difficult metals to alloy in usual furnaces as these are very reactive metals, having great differences in melting point anti specific gravity. To produce an alloy of titanium and tantalum, cold crucible levitation melting (CCLM) is effective in obtaining a uniform composition. Notable features of CCLM are that it can (1) melt metals with a high melting point, (2) create an alloy of uniform composition with a strong stirring effect by an electromagnetic force and (3) allow metals to be melted without contamination. We have melted 850 g of titanium and 150 g of tantalum by a CCLM furnace and have successfully made 1.0 kg of uniform composite Ti-15wt.% Ta alloy. It is noteworthy that the alloy was produced from pure base metals which were not alloyed beforehand and was made by a single melting (no re-melting) process. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:208 / 213
页数:6
相关论文
共 50 条
  • [1] Development of 50kg Cold Crucible Levitation Melting furnace
    Kainuma, K
    Take, T
    Fujita, M
    Hayashi, S
    NON-LINEAR ELECTROMAGNETIC SYSTEMS: ADVANCED TECHNIQUES AND MATHEMATICAL METHODS, 1998, 13 : 753 - 756
  • [3] Electromagnetic model of levitation melting with cold crucible
    Deng, K
    Zhou, YM
    Ren, ZM
    Zhu, SJ
    Wei, JH
    Jiang, GC
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 1996, 6 (02) : 12 - 17
  • [4] Electromagnetic characteristics of levitation melting with cold crucible
    Deng, K
    Zhou, YM
    Ren, ZM
    Gong, T
    Jiang, GC
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 1999, 9 (02) : 387 - 392
  • [5] ELECTROMAGNETIC MODEL OF LEVITATION MELTING WITH COLD CRUCIBLE
    Deng Kang
    Zhou Yueming
    Ren Zhongming
    Zhu Shoujun
    Wei Jihe
    Jiang Guochang(Shanghai Enhanced Laboratory of Ferrometallurgy
    Transactions of Nonferrous Metals Society of China, 1996, (02) : 12 - 17
  • [6] Corrosion behaviour of some titanium dental alloys synthesized by cold crucible levitation melting
    Mareci, D.
    Chelariu, R.
    Ciurescu, G.
    Sutiman, D.
    Gordin, D. M.
    Gloriant, T.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2010, 12 (07): : 1590 - 1596
  • [7] NUMERICAL SIMULATION OF ELECTROMAGNETIC LEVITATION IN A COLD CRUCIBLE FURNACE
    Spitans, S.
    Baake, E.
    Jakovcs, A.
    Franz, H.
    MAGNETOHYDRODYNAMICS, 2015, 51 (03): : 567 - 578
  • [8] THE LEVITATION MELTING PROCESS USING COLD CRUCIBLE TECHNIQUE
    GAGNOUD, A
    ETAY, J
    GARNIER, M
    TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1988, 28 (01) : 36 - 40
  • [10] Development of large-size cold crucible levitation melting
    Kainuma, K
    Fujita, M
    Take, T
    Ashida, Y
    Tadano, H
    Yamazaki, M
    PROCEEDINGS OF THE XIII INTERNATIONAL CONGRESS ON ELECTRICITY APPLICATIONS, VOLS 1 AND 2, 1996, : MII9 - MII16