Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife:: Marker placement and early results

被引:106
|
作者
Nuyttens, J. J.
Prevost, J. -B.
Praag, J.
Hoogeman, M.
Van Klaveren, R. J.
Levendag, P. C.
Pattynama, P. M. T.
机构
[1] Erasmus MC, Dr Daniel Den Hoed Canc Ctr, Dept Radiat Oncol, NL-3008 AE Rotterdam, Netherlands
[2] Erasmus MC, Dr Daniel Den Hoed Canc Ctr, Dept Pulmonol, NL-3008 AE Rotterdam, Netherlands
[3] Erasmus MC, Dr Daniel Den Hoed Canc Ctr, Dept Intervent Radiol, NL-3008 AE Rotterdam, Netherlands
关键词
D O I
10.1080/02841860600902205
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Lung tumor tracking during stereotactic radiotherapy with the CyberKnife requires the insertion of markers in or close to the tumor. To reduce the risk of pneumothorax, three methods of marker placement were used: 1) intravascular coil placement, 2) percutaneous intrathoracal, and 3) percutaneous extrathoracal placement. We investigated the toxicity of marker placement and the tumor response of the lung tumor tracking treatment. Markers were placed in 20 patients with 22 tumors: 13 patients received a curative treatment, seven a palliative. The median Charlson Comorbidity Score was 4 (range: 1 - 8). Platinum fiducials and intravascular embolisation coils were used as markers. In total, 78 markers were placed: 34 intrathoracal, 23 intravascular and 21 extrathoracal. The PTV equaled the GTV + 5 mm. A median dose of 45 Gy (range: 30 - 60 Gy, in 3 fractions) was prescribed to the 70 - 85% isodose. The response was evaluated with a CTscan performed 6 - 8 weeks after the last treatment and routinely thereafter. The median follow-up was 4 months (range: 2 - 11). No severe toxicity due to the marker placement was seen. Pneumothorax was not seen. The local control was 100%. Four tumors in four patients showed a complete response, 15 tumors in 14 patients a partial response, and three tumors in two patients with metastatic disease had stable disease. No severe toxicity of marker placement was seen due to the appropriate choice of one of the three methods. CyberKnife tumor tracking with markers is feasible and resulted in excellent tumor response. Longer follow-up is needed to validate the local control.
引用
收藏
页码:961 / 965
页数:5
相关论文
共 50 条
  • [1] Lung tumor tracking during stereotactic radiotherapy treatment with the cyberknife: Marker placement and early results
    Nuyttens, J.
    Prevost, J-B.
    Praag, J.
    Hoogeman, M.
    Pattynama, P.
    Levendag, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S488 - S488
  • [2] FOUR-DIMENSIONAL LUNG TUMOR TRACKING DURING STEREOTACTIC RADIOTHERAPY: EARLY RESULTS
    Nuyttens, J.
    van Zijp, N. van der Voort
    Hoogeman, M.
    Praag, J.
    van Klaveren, R.
    Pattynama, P.
    Levendag, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S78 - S78
  • [3] Dosimetric Effect of Intrafraction Tumor Motion in Lung Stereotactic Body Radiotherapy Using CyberKnife Static Tracking System
    Chang, Yu
    Liu, Hong-Yuan
    Liang, Zhi-Wen
    Nie, Xin
    Yang, Jing
    Liu, Gang
    Li, Qin
    Yang, Zhi-Yong
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18
  • [4] Prospective evaluation of fiducial marker placement quality and toxicity in liver CyberKnife stereotactic body radiotherapy
    Dutta, Debnarayan
    Kataki, Kaushik Jagannath
    George, Shibu
    Reddy, Sruthi K.
    Sashidharan, Ajay
    Kannan, Rajesh
    Madhavan, Ram
    Nair, Haridas
    Tatineni, Tushar
    Holla, Raghavendra
    [J]. RADIATION ONCOLOGY JOURNAL, 2020, 38 (04): : 253 - 261
  • [5] CyberKnife Stereotactic Ablative Radiotherapy for Lung Tumors
    Gibbs, Iris C.
    Loo, Billy W., Jr.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (06) : 589 - 596
  • [6] Extracranial Stereotactic Radiotherapy: Preliminary Results with the CyberKnife®
    Lartigau, Eric
    Mirabel, Xavier
    Prevost, Bernard
    Lacornerie, Thomas
    Dubus, Francois
    Sarrazin, Thierry
    [J]. ONKOLOGIE, 2009, 32 (04): : 209 - 215
  • [7] Early results of CyberKnife image-guided robotic stereotactic radiosurgery for treatment of lung tumors
    Brown, William T.
    Wu, Xiaodong
    Wen, B-Chen
    Fowler, John F.
    Fayad, Fahed
    Amendola, Beatriz E.
    Garcia, Silvio
    De la Zerda, Alberto
    Huang, Zhicong
    Schwade, James G.
    [J]. COMPUTER AIDED SURGERY, 2007, 12 (05) : 253 - 261
  • [8] Feasibility and efficacy of cyberknife radiotherapy for lung cancer: Early results
    Castelli, J.
    Thariat, J.
    Benezery, K.
    Padovani, B.
    Ducreux, D.
    Venissac, N.
    Poudenx, M.
    Otto, J.
    Mouroux, J.
    Bondiau, P. -Y.
    [J]. CANCER RADIOTHERAPIE, 2008, 12 (08): : 793 - 799
  • [9] Intravascular Placement of Metallic Coils as Lung Tumor Markers for CyberKnife Stereotactic Radiation Therapy
    Karaman, Kutlay
    Dokdok, A. Murat
    Karadeniz, Oktay
    Ceylan, Cemile
    Engin, Kayihan
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (03) : 626 - 631
  • [10] CYBERKNIFE STEREOTACTIC BODY RADIOTHERAPY FOR OLIGOMETASTATIC LUNG TUMORS
    Beltramo, G.
    Bergantin, A.
    Martinotti, A.
    Bonfanti, P.
    Bianchi, L. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S567 - S567