An Implanted Telemetry System for Transcutaneous Biosignal Transmission

被引:0
|
作者
Zhang, Yong [1 ]
机构
[1] Univ Huddersfield, Dept Engn & Technol, Huddersfield, W Yorkshire, England
基金
英国国家替代、减少和改良动物研究中心;
关键词
Implantable; low power; telemetry; RF powering; transcutaneous; POWER;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents the initial project developments of a radio-based system to transmit EMG signals from within the body to the outside without using transcutaneous cables. Due to current electronic system getting smaller and the development of new biocompatible materials, biomedical implants are becoming much more common. No current implantable system, either commercially available or reported in the research literature, deliver the combination of channel count, bandwidth and long operation time without battery change required for our application. The proposed research will overcome these limitations. Signals are digitised and transmitted through the skin wirelessly over high bandwidth. Power is supplied by radio frequency induction, from an external coil placed over the back of animal.
引用
下载
收藏
页码:491 / 494
页数:4
相关论文
共 50 条
  • [1] A transcutaneous data telemetry system tolerant to power telemetry interference
    Zhou, Mingcui
    Liu, Wentai
    Wang, Guoxing
    Sivaprakasam, Mohanasankar
    Yuce, Mehmet R.
    Weiland, James D.
    Humayun, Mark S.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2946 - +
  • [2] Basic evaluation of signal transmission coil in transcutaneous magnetic telemetry system for artificial hearts
    Takura, T
    Ishiai, H
    Sato, F
    Matsuki, H
    Sato, T
    IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (10) : 4173 - 4175
  • [3] IMPLANTED TELEMETRY SYSTEM MEASURES PRESSURE
    不详
    ELECTRONIC ENGINEER, 1967, 26 (07): : 22 - &
  • [5] Transcutaneous optical telemetry system with infrared laser diode
    Inoue, K
    Shiba, K
    Shu, EM
    Koshiji, K
    Tsukahara, K
    Oh-umi, T
    Masuzawa, T
    Tatsumi, E
    Taenaka, Y
    Takano, H
    ASAIO JOURNAL, 1998, 44 (06) : 841 - 844
  • [6] Transcutaneous optical telemetry system - Investigation on deviation characteristics
    Inoue, K
    Shiba, K
    Shu, E
    Koshiji, K
    Tsukahara, K
    Ohu-mi, T
    Masuzawa, T
    Tatsumi, E
    Taenaka, Y
    Takano, H
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2235 - 2237
  • [7] A System-Level View of Optimizing High-Channel-Count Wireless Biosignal Telemetry
    Chandler, Rodney J.
    Gibson, Sarah
    Karkare, Vaibhav
    Farshchi, Shahin
    Markovic, Dejan
    Judy, Jack W.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5525 - 5530
  • [8] TELEMETRY SYSTEM FOR CONTINUOUS MEASUREMENT OF VOLTAGE OF AN IMPLANTED BIOELECTRIC BATTERY
    FONTENIER, G
    MEDICAL & BIOLOGICAL ENGINEERING, 1975, 13 (05): : 696 - 699
  • [9] Use of the DSI/Ponemah Jacketed External Telemetry (JET) System and Implanted Devices in Dog Telemetry
    Wu, Rui
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2017, 88 : 225 - 225
  • [10] A telemetry system for the continuous measurement of the voltage of an implanted bioelectric battery
    Fontenier, G.
    1975, 13 (05): : 696 - 699