The influence of asymmetry in drop shape on an interfacial tension measurement

被引:9
|
作者
Hayami, Y
机构
[1] Department of Home Economies, Chikushi Jogakuen Junior College, Dazaifu
关键词
asymmetry of drop shape; pendant drop measurement; selected plane method; interfacial tension; three-phase contact line;
D O I
10.1007/BF00653062
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A requirement of the drop method for interfacial tension measurement is that the drop must have an axi-symmetry. The drop shape was measured as a function of the angle of the rod from which the drop was hanging. The deviation of the interfacial tension caused by asymmetry was calculated using the selected plane method in the pendant drop technique. A sharp maximum was seen in the interfacial tension vs angle curve when the rod was at the vertical point. The maximum value was concluded as being the true value of the interfacial tension. Both decreases in the pressure difference and in the curvature of the drop associated with an increase in the rod-angle are a counterpart with each other to satisfy the Bashforth and Adams equation. The underestimation of the interfacial tension seems to be caused by the apparent inconsistency between the decreases in the curvature and pressure difference terms. The rigorous mechanical setup demonstrated here is necessary to attain the true axi-symmetric condition, and thus obtain a reliable value for the interfacial tension.
引用
收藏
页码:643 / 647
页数:5
相关论文
共 50 条
  • [1] MEASUREMENT OF INTERFACIAL TENSION FROM SHAPE-OF A ROTATING DROP
    PRINCEN, HM
    ZIA, IYZ
    MASON, SG
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1967, 23 (01) : 99 - &
  • [2] Dynamic interfacial tension measurement method using axisymmetric drop shape analysis
    Bagalkot, Nikhil
    Hamouda, Aly A.
    Isdahl, Ole Morten
    METHODSX, 2018, 5 : 676 - 683
  • [3] Measurement of interfacial tension by drop retraction analysis
    Guido, S
    Villone, M
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1999, 209 (01) : 247 - 250
  • [4] Measurement of interfacial tension by a deformed drop retraction method
    Son, Y
    Yoon, JT
    POLYMER, 2001, 42 (16) : 7209 - 7213
  • [5] Interfacial Tension Measurements Using MRI Drop Shape Analysis
    Hussain, R.
    Vogt, S. J.
    Honari, A.
    Hollingsworth, K. G.
    Sederman, A. J.
    Mitchell, J.
    Johns, M. L.
    LANGMUIR, 2014, 30 (06) : 1566 - 1572
  • [6] Improvement of interfacial tension measurement using a captive bubble in conjunction with axisymmetric drop shape analysis (ADSA)
    Zuo, YY
    Ding, M
    Bateni, A
    Hoorfar, M
    Neumann, AW
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2004, 250 (1-3) : 233 - 246
  • [7] Measurement of the interfacial tension of bitumen at high temperature with a drop tensiometer
    Verlhac, Patrick
    Van Nieuwenhuyze, Kathleen
    Verzaro, Francis
    Cagna, Alian
    Boinon, Christian
    Bulletin des Laboratoires des Ponts et Chaussees, 2001, (235): : 3 - 17
  • [8] MEASUREMENT OF DYNAMIC INTERFACIAL-TENSION BY AN EXPANDING DROP TENSIOMETER
    NAGARAJAN, R
    WASAN, DT
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1993, 159 (01) : 164 - 173
  • [9] THE MEASUREMENT OF SURFACE AND INTERFACIAL-TENSION BY THE AXISYMMETRIC DROP TECHNIQUE
    BOYCE, JF
    SCHURCH, S
    ROTENBERG, Y
    NEUMANN, AW
    COLLOIDS AND SURFACES, 1984, 9 (04): : 307 - 317
  • [10] INTERFACIAL-TENSION MEASUREMENT WITH A SPINNING DROP IN GYROSTATIC EQUILIBRIUM
    MANNING, CD
    SCRIVEN, LE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (12): : 1699 - 1705