A facile and highly sensitive impedimetric DNA biosensor with ultralow background response based on in situ reduced graphene oxide

被引:5
|
作者
Wu, Aiqun [1 ]
Wang, Qingxiang [1 ]
Zhu, Qionghua [1 ]
Ni, Jiancong [1 ]
Gao, Feng [1 ]
机构
[1] Minnan Normal Univ, Dept Chem & Environm Sci, Fujian Prov Univ Key Lab Analyt Sci, Zhangzhou 363000, Peoples R China
来源
RSC ADVANCES | 2015年 / 5卷 / 110期
基金
中国国家自然科学基金;
关键词
LABEL-FREE DETECTION; ELECTROCHEMICAL BIOSENSOR; SELECTIVE DETECTION; MODIFIED ELECTRODE; NANOCOMPOSITE; HYBRIDIZATION; IMMUNOSENSOR; REDUCTION; GRAPHITE; SENSOR;
D O I
10.1039/c5ra16233e
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel electrochemical impedimetric DNA sensor was constructed based on in situ chemical reduction of graphene oxide (GO) that had been attached at a DNA modified electrode. First, the mercapto-modified probe DNA was anchored on a gold electrode surface through the Au-S bond. Then the GO was adsorbed on the probe DNA through the unique p-p stacking, which was followed by incubation in sodium borohydride (NaBH4) solution to in situ reduce the GO to the reduced form (rGO). Thus, a highly conductive biointerface with ultralow charge-transfer resistance was obtained. When the biosensor was hybridized with the target DNA to form the rigid double-stranded DNA, the rGO was released from the electrode surface and the charge-transfer resistance increased again. Compared with the analogous sensing interface without pre-accumulation of GO, the signal variation ratio was found to increase by 8-fold upon hybridization as determined by electrochemical impedance spectra, suggesting a higher signal-to-noise of the constructed biosensor. Quantitative analysis experiments showed that the impedance change values exhibited a good linear relationship with the logarithmic values of target DNA concentration over a wide range from 1.0 x 10(-15) M to 1.0 x 10(-9) M. The detection limit was estimated to be as low as 2.9 x 10(-16) M. The biosensor also presented excellent selectivity, good regeneration ability and outstanding stability.
引用
收藏
页码:90983 / 90990
页数:8
相关论文
共 50 条
  • [1] A sensitive impedimetric DNA biosensor for the determination of the HIV gene based on electrochemically reduced graphene oxide
    Gong, Qiaojuan
    Yang, Haiying
    Dong, Yanyun
    Zhang, Wenchan
    ANALYTICAL METHODS, 2015, 7 (06) : 2554 - 2562
  • [2] Synchronous Electrosynthesis of Poly(xanthurenic acid)-Reduced Graphene Oxide Nanocomposite for Highly Sensitive Impedimetric Detection of DNA
    Yang, Tao
    Li, Qianhe
    Meng, Le
    Wang, Xiaohong
    Chen, Wenwen
    Jiao, Kui
    ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (09) : 3495 - 3499
  • [3] Highly Sensitive Amperometric α-Ketoglutarate Biosensor Based on Reduced Graphene Oxide-Gold Nanocomposites
    Peng, Gang
    Yu, Yadong
    Chen, Xiaojun
    Huang, He
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 2020 (2020)
  • [4] A highly sensitive impedimetric sensor based on iron (III) porphyrin and thermally reduced graphene oxide for detection of Bisphenol A
    Hsine, Z.
    Bizid, S.
    Zahou, I.
    Hassen, L. Ben Haj
    Nasri, H.
    Mlika, R.
    SYNTHETIC METALS, 2018, 244 : 27 - 35
  • [5] A novel impedimetric biosensor based on graphene oxide/gold nanoplatform for detection of DNA arrays
    Gupta, Vinod Kumar
    Yola, Mehmet Lutfi
    Qureshi, Munewar Saeed
    Solak, Ali Osman
    Atar, Necip
    Ustundag, Zafer
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 1201 - 1211
  • [6] Facile Patterning of Reduced Graphene Oxide Film into Microelectrode Array for Highly Sensitive Sensing
    Li, Fengwang
    Xue, Mianqi
    Ma, Xinlei
    Zhang, Meining
    Cao, Tingbing
    ANALYTICAL CHEMISTRY, 2011, 83 (16) : 6426 - 6430
  • [7] HIGHLY SELECTIVE AND SENSITIVE ELECTROCHEMICAL BIOSENSOR BASED ON ELECTROCHEMICALLY REDUCED GRAPHENE OXIDE FOR DETECTION OF MIRNA AS A CANCER BIOMARKER
    Vanova, Veronika
    Sedlackova, Eliska
    Hynek, David
    Richtera, Lukas
    Bytesnikova, Zuzana
    Adam, Vojtech
    11TH INTERNATIONAL CONFERENCE ON NANOMATERIALS - RESEARCH & APPLICATION (NANOCON 2019), 2020, : 385 - 390
  • [8] Highly sensitive impedimetric aptasensor based on covalent binding of gold nanoparticles on reduced graphene oxide with good dispersity and high density
    Qian, Jing
    Jiang, Ling
    Yang, Xingwang
    Yan, Yuting
    Mao, Hanping
    Wang, Kun
    ANALYST, 2014, 139 (21) : 5587 - 5593
  • [9] Gold nanoparticles/single-stranded DNA-reduced graphene oxide nanocomposites based electrochemical biosensor for highly sensitive detection of cholesterol
    Shuyao Wu
    Chengquan Sui
    Chong Wang
    Yulu Wang
    Dongqing He
    Ying Sun
    Yu Zhang
    Qingbo Meng
    Tianyi Ma
    XiMing Song
    Frontiers of Chemical Science and Engineering, 2021, 15 (06) : 1572 - 1582
  • [10] Gold nanoparticles/single-stranded DNA-reduced graphene oxide nanocomposites based electrochemical biosensor for highly sensitive detection of cholesterol
    Shuyao Wu
    Chengquan Sui
    Chong Wang
    Yulu Wang
    Dongqing He
    Ying Sun
    Yu Zhang
    Qingbo Meng
    Tianyi Ma
    Xi-Ming Song
    Frontiers of Chemical Science and Engineering, 2021, 15 : 1572 - 1582