Reliability and validity of the Turkish version of Function in Sitting Test (FIST-T) in stroke

被引:3
|
作者
Erol, Busra Nur [1 ]
Aydogan Arslan, Saniye [2 ]
Yasar, Evren [3 ]
Keskin, Esra Dilek [4 ]
Demirci, Cevher Savcun [5 ]
机构
[1] Ankara Univ, Vocat Sch Haymana, Physiotherapy Programme, Ankara, Turkey
[2] Kirikkale Univ, Dept Physiotherapy & Rehabil, Fac Hlth Sci, Kirikkale, Turkey
[3] Univ Hlth Sci, Gulhane Fac Med, Dept Phys Med & Rehabil, Ankara, Turkey
[4] Kirikkale Univ, Dept Phys Med & Rehabil, Fac Med, Kirikkale, Turkey
[5] Balikesir Univ, Dept Physiotherapy & Rehabil, Fac Hlth Sci, Balikesir, Turkey
关键词
Function in sitting test; stroke; reliability; validity; sitting balance;
D O I
10.1080/10749357.2020.1871284
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Trunk control in sitting position after stroke is one of the most important determinants of independence in daily living activities and there is no gold standard assessment used to measure sitting postural control. Objectives: The aim of this study is to determine the reliability and validity of the Turkish version of Function in Sitting Test (FIST-T). Methods: After translation was conducted, Function in Sitting Test, Berg Balance Scale, Functional Independent Measure and Trunk Impairment Scale were applied to 72 stroke patients (mean age was 59.26 +/- 16.38 years; post-stroke time was 95.93 +/- 59.64 days). For reliability and validity analysis the spearman correlation analysis was used. Results: A positive, high correlation was found between the first application and repetition of Function in Sitting Test-T (ICC = 0.97, r = 0.95, p = .001). The internal consistency was high (Cronbach Alpha = 0.97), interrater correlation was high (Cronbach Alpha = 0.98) and a positive, high correlation was found with the scores obtained from the Berg Balance Scale (r = 0.82, p = .001), Functional Independent Measure (r = 0.84, p = .001) and Trunk Impairment Scale (r = 0.80, p = .001). Conclusions: It is concluded that the Turkish version of Function in Sitting Test is a valid and reliable scale for use in stroke patients, in clinical and scientific researches.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [1] Reliability of the Function in Sitting Test (FIST)
    Gorman, Sharon L.
    Rivera, Monica
    McCarthy, Lise
    [J]. REHABILITATION RESEARCH AND PRACTICE, 2014, 2014
  • [2] Validity and reliability of the Turkish version of the Ottawa Sitting Scale in patients with acute stroke
    Yasa, Mustafa Ertugrul
    Arslan, Saniye Aydogan
    Sahan, Tezel Yildirim
    Caglar, Derya
    Demirci, Cevher Savcun
    Demir, Pervin
    [J]. DISABILITY AND REHABILITATION, 2024, 46 (17) : 3992 - 3997
  • [3] Investigation of the reliability and validity of the Turkish version of the Sitting Balance Scale in individuals with stroke
    capraz, Kuebra
    Aydogan Arslan, Saniye
    colak, Teoman
    [J]. ACTA NEUROLOGICA BELGICA, 2024, 124 (01) : 81 - 89
  • [4] Investigation of the reliability and validity of the Turkish version of the Sitting Balance Scale in individuals with stroke
    Kübra Çapraz
    Saniye Aydoğan Arslan
    Teoman Çolak
    [J]. Acta Neurologica Belgica, 2024, 124 : 81 - 89
  • [5] Validation and reliability of the Spanish version of the Function in Sitting Test (S-FIST) to assess sitting balance in subacute post-stroke adult patients
    Cabanas-Valdes, Rosa
    Bagur-Calafat, Caritat
    Maria Caballero-Gomez, Fernanda
    Cervera-Cuenca, Carmen
    Moya-Valdes, Raul
    Ramon Rodriguez-Rubio, Pere
    Urrutia, Gerard
    [J]. TOPICS IN STROKE REHABILITATION, 2017, 24 (06) : 472 - 478
  • [6] RELIABILITY AND VALIDITY OF TURKISH VERSION OF THE BRIEF-BESTEST -T IN STROKE PATIENTS
    Aydogan Arslan, Saniye
    Demirci, Cevher Savcun
    Katirci Kirmaci, Zekiye Ipek
    Ugurlu, Kubra
    Keskin, Esra Dilek
    [J]. TOPICS IN STROKE REHABILITATION, 2021, 28 (07) : 488 - 497
  • [7] Reliability and validity of Turkish version of COPD assessment test
    Yorgancioglu, Arzu
    Polatli, Mehmet
    Aydemir, Omer
    Demirci, Nilgun Yilmaz
    Kirkil, Gamze
    Atis, Sibel Nayci
    Kokturk, Nurdan
    Uysal, Atilla
    Akdemir, Selim Erkan
    Ozgur, Eylem Sercan
    Gunakan, Gonca
    [J]. TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2012, 60 (04): : 314 - 320
  • [8] The Validity and Reliability of the Turkish Version of the Brief Irritability Test
    Karadere, Mehmet Emrah
    Cifteci, Kursad
    Elbay, Rumeysa Yeni
    Yilmaz, Hakan
    Karatepe, Hasan Turan
    [J]. ALPHA PSYCHIATRY, 2021, 22 (06): : 318 - 323
  • [9] Validity and reliability of Turkish version of the gugging swallowing screen test in the early period of hemispheric stroke
    Umay, Ebru Karaca
    Gurcay, Eda
    Bahceci, Kadir
    Ozturk, Erhan
    Yilmaz, Volkan
    Gundogdu, Ibrahim
    Ceylan, Tijen
    Eren, Yasemin
    Cakci, Aytul
    [J]. NEUROLOGICAL SCIENCES AND NEUROPHYSIOLOGY, 2018, 35 (01): : 6 - 13
  • [10] The reliability and validity of Turkish version of Childhood Asthma Control Test
    Sekerel, B. E.
    Soyer, O. U.
    Keskin, O.
    Uzuner, N.
    Yazicioglu, M.
    Kilic, M.
    Artac, H.
    Ozmen, S.
    Can, D.
    Zeyrek, D.
    Cokugras, H.
    Canitez, Y.
    Aydogan, M.
    Kuyucu, S.
    INal, A.
    Gurkan, F.
    Orhan, F.
    Yilmaz, O.
    Boz, A. B.
    Tahan, F.
    Cevit, O.
    [J]. QUALITY OF LIFE RESEARCH, 2012, 21 (04) : 685 - 690