Comparison between On-Line High-Efficiency Hemodiafiltration and Conventional High-Flux Hemodialysis for Polyclonal Free Light Chain Removal

被引:11
|
作者
Lamy, Thomas [1 ]
Henri, Patrick [1 ]
Lobbedez, Thierry [1 ]
Comby, Elisabeth [2 ]
Ryckelynck, Jean-Philippe [1 ]
Ficheux, Maxence [1 ]
机构
[1] CHU Clemenceau, Dept Nephrol, FR-14033 Caen, France
[2] CHU Clemenceau, Dept Immunol, FR-14033 Caen, France
关键词
Hemodialysis; Hemodiafiltration; Polyclonal free light chains; SERUM; DIALYSIS; HEMOFILTRATION; MORTALITY; BETA-2-MICROGLOBULIN; CLEARANCE; RISK;
D O I
10.1159/000357968
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Polyclonal free light chains (FLC) are considered as middle molecular weight uremic toxins in chronic kidney disease. In this study, we investigate polyclonal FLC removal by comparing conventional high-flux hemodialysis (HD) and online high-efficiency hemodiafiltration (ol-HDF) in end-stage renal disease patients. Methods: We analyzed 31 chronic dialysis patients who were treated by HD then by postdilution ol-HDF during a prospective study. All patients were anuric and without monoclonal gammopathy. Serum pre- and postdialysis FLC were collected during 4 sessions: 1 HD session and 3 ol-HDF sessions. We calculated the reduction ratio using kinetic modeling. Results: The kappa reduction ratio was higher with ol-HDF than with HD (66 +/- 14 vs. 52 +/- 13%, p < 0.001). However, the lambda reduction ratio was not significantly higher with ol-HDF (37 +/- 20 vs. 37 +/- 15%, p = 0.67). Furthermore, predialysis kappa- and lambda-FLC increased with ol-HDF compared with HD (kappa 155 +/- 82 vs. 87 +/- 47 mg/l, p < 0.05; lambda 101 +/- 46 vs. 72 +/- 41 mg/l, p < 0.05). Postdialysis FLC levels were raised only for lambda-FLC with ol-HDF (74 +/- 39 vs. 53 +/- 31 mg/l, p < 0.05) and were not significantly different for kappa. Conclusions: This study shows that lambda-FLC removal is better in ol-HDF compared with HD, whereas there is no difference in kappa-FLC removal. Surprisingly, predialysis kappa and lambda levels are both increased in ol-HDF, which is disturbing since polyclonal excess of lambda-FLC is associated with mortality in chronic kidney disease. (C) 2014 S. Karger AG, Basel
引用
收藏
页码:93 / 98
页数:6
相关论文
共 50 条
  • [1] FGF-23 removal is improved by on-line high-efficiency hemodiafiltration compared to conventional high flux hemodialysis
    Patrier, Laure
    Dupuy, Anne-Marie
    Vallee, Alexandre Granger
    Chalabi, Lotfi
    Morena, Marion
    Canaud, Bernard
    Cristol, Jean-Paul
    JOURNAL OF NEPHROLOGY, 2013, 26 (02) : 342 - 349
  • [2] Vancomycin hemodialysis: Clearance differences between high-flux hemodialysis and on-line hemodiafiltration
    Rodriguez, Nestor
    Gomez, Miquel
    Rico, Naira
    Maria Campistol, Josep
    Maduell, Francisco
    ARTIFICIAL ORGANS, 2019, 43 (03) : 261 - 269
  • [3] A comparison of on-line hemodiafiltration and high-flux hemodialysis: A prospective clinical study
    Ward, RA
    Schmidt, S
    Hullin, J
    Hillebrand, GF
    Samtleben, W
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2000, 11 (12): : 2344 - 2350
  • [4] Infective spondylodiscitis in patients on high-flux hemodialysis and on-line hemodiafiltration
    Abid, Saima
    De Silva, Shamila
    Warwicker, Paul
    Farrington, Ken
    HEMODIALYSIS INTERNATIONAL, 2008, 12 (04) : 463 - 470
  • [5] Osteocalcin and myoglobin removal in on-line hemodiafiltration versus low- and high-flux hemodialysis
    Maduell, F
    Navarro, V
    Cruz, MC
    Torregrosa, E
    Garcia, D
    Simon, V
    Ferrero, JA
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 40 (03) : 582 - 589
  • [6] 2.6 Comparison of High-Efficiency On-Line Hemodiafiltration and High-Flux Hemodialysis on Vascular Function and Structure in End-Stage Renal Disease Patients
    J. Bellien
    C. Freguin
    F. Le Roy
    I. Remy-Jouet
    M. Hanoy
    C. Monteil
    C. Thuillez
    M. Godin
    R. Joannides
    Artery Research, 2012, 6 (4) : 144 - 144
  • [7] On-line hemodiafiltration:: Comparison of eleven different high-flux dialyzers
    Maduell, F
    Navarro, V
    Hernández-Jaras, J
    Calvo, C
    NEFROLOGIA, 2000, 20 (03): : 269 - 276
  • [8] PHOSPHATE (P) REMOVAL BY CONVENTIONAL DIALYSIS (CHD), HIGH-EFFICIENCY DIALYSIS (HEHD) AND HIGH-FLUX HEMODIAFILTRATION (HFHDF)
    SHINABERGER, JH
    MILLER, JH
    VONALBERTINI, B
    GARDNER, PW
    COBURN, JW
    KIDNEY INTERNATIONAL, 1987, 31 (01) : 245 - 245
  • [9] The effects of on-line hemodiafiltration on oxidative stress and β2-microglobulin in comparison with high-flux hemodialysis
    Kim, DK
    Kim, HJ
    Kim, HJ
    Ryu, DR
    Kang, SW
    Choi, KH
    Lee, HY
    Han, DS
    Kang, EW
    Shin, SK
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 : V126 - V126
  • [10] Evaluation of high-flux hemodiafiltration efficiency using an on-line urea monitor
    Canaud, B
    Bosc, JY
    Leblanc, M
    Garred, LJ
    Vo, T
    Mion, C
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1998, 31 (01) : 74 - 80