WHO Multicenter Evaluation of FACSCount CD4 and Pima CD4 T-Cell Count Systems: Instrument Performance and Misclassification of HIV-Infected Patients

被引:0
|
作者
Wade, Djibril [1 ,2 ,3 ]
Daneau, Geraldine [1 ]
Aboud, Said [4 ]
Vercauteren, Gaby H. [5 ]
Urassa, Willy S. K. [5 ]
Kestens, Luc [1 ,3 ]
机构
[1] Inst Trop Med Antwerp, Dept Biomed Sci, Immunol Lab, Antwerp, Belgium
[2] Univ Cheikh Anta Diop, Le Dantec Univ Teaching Hosp, Lab Bacteriol Virol, Immunol Unit, Dakar 92000, Senegal
[3] Univ Antwerp, Dept Biomed Sci, B-2020 Antwerp, Belgium
[4] Muhimbili Univ Hlth & Allied Sci, Dept Microbiol & Immunol, Dar Es Salaam, Tanzania
[5] WHO, CH-1211 Geneva, Switzerland
关键词
CD4; count; CD4%; resource-limited settings; Pima CD4; FACSCount CD4; POINT-OF-CARE; FLOW-CYTOMETRY; VIRAL LOAD; LYMPHOCYTE COUNTS; ENUMERATION; ANALYZER; SETTINGS; BLOOD; INDIVIDUALS; VALIDATION;
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background: CD4(+) T-cell counts are used to screen and follow-up HIV-infected patients during treatment. As part of the World Health Organization prequalification program of diagnostics, we conducted an independent multicenter evaluation of the FACSCount CD4 and the Pima CD4, using the FACSCalibur as reference method. Methods: A total of 440 paired capillary and venous blood samples were collected from HIV-infected patients attending the HIV outpatient clinic in Antwerp, Belgium, and the HIV care and treatment center in Dar es Salam, Tanzania. Capillary blood was run on Pima analyzer, whereas venous blood was analyzed on FACSCount, Pima, and FACSCalibur instruments. Precision and agreement between methods were assessed. Results: The FACSCount CD4 results were in agreement with the FACSCalibur results with relative bias of 0.4% and 3.1% on absolute CD4 counts and an absolute bias of -0.6% and -1.1% on CD4% in Antwerp and Dar es Salam, respectively. The Pima CD4 results were in agreement with the FACSCalibur results with relative bias of -4.1% and -9.4% using venous blood and of -9.5% and -0.9% using capillary blood in Antwerp and Dar es Salam, respectively. At the threshold of 350 cells per microliter, the FACSCount CD4 and Pima CD4 using venous and capillary blood misclassified 7%, 9%, and 13% of patients, respectively. Conclusions: The FACSCount CD4 provides reliable CD4 counts and CD4% and is suitable for monitoring adult and pediatric HIV patients in moderate-volume settings. The Pima CD4 is more suitable for screening eligible adult HIV patients for antiretroviral treatment initiation in low-volume laboratories.
引用
收藏
页码:E98 / E107
页数:10
相关论文
共 50 条
  • [1] CD4 count and CD4% in African HIV-infected people
    Anglaret, X
    Sylla-Koko, F
    Diagbouga, S
    Combe, P
    Van de Perre, P
    Dabis, F
    [J]. INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1998, 27 (05) : 928 - 929
  • [2] Relationship between CD4 count and CD4% in HIV-infected people
    Yu, LM
    Easterbrook, PJ
    Marshall, T
    [J]. INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1997, 26 (06) : 1367 - 1372
  • [3] CD4 T-Cell Enumeration in a Field Setting: Evaluation of CyFlow Counter Using the CD4 Easy Count Kit-Dry and Pima CD4 Systems
    Wade, Djibril
    Diaw, Papa Alassane
    Daneau, Geraldine
    Camara, Makhtar
    Dieye, Tandakha Ndiaye
    Mboup, Souleymane
    Kestens, Luc
    [J]. PLOS ONE, 2013, 8 (09):
  • [4] Autoimmune T-cell response to the CD4 molecule in HIV-infected patients
    Caporossi, AP
    Bruno, G
    Salemi, S
    Mastroianni, C
    Falciano, M
    Salotti, A
    Bergami, N
    Santilio, I
    Nisini, R
    Barnaba, V
    [J]. VIRAL IMMUNOLOGY, 1998, 11 (01) : 9 - 17
  • [5] SERUM CAROTENE CORRELATES WITH CD4 T-CELL COUNT AND IS FREQUENTLY DECREASED IN HIV-INFECTED PATIENTS
    ULLRICH, R
    SCHNEIDER, T
    SCHMIDT, W
    GOES, R
    HEISE, W
    RIECKEN, EO
    ZEITZ, M
    [J]. GASTROENTEROLOGY, 1994, 106 (04) : A787 - A787
  • [6] DETECTION OF T-CELL CD4 EPITOPES IN HIV-INFECTED INDIVIDUALS
    KUNKL, A
    VALLE, MT
    FENOGLIO, D
    DODI, F
    MORANDI, N
    RIZZO, F
    MANCA, F
    [J]. EUROPEAN JOURNAL OF HISTOCHEMISTRY, 1994, 38 : 41 - 46
  • [7] Clinical significance of discordant CD4 count and CD4 percentage in HIV-infected individuals
    Le, TP
    Tribble, DR
    Zhou, SYJ
    Malone, L
    Chung, RC
    Rusnak, JM
    Wagner, KF
    [J]. AIDS, 1997, 11 (11) : 1395 - 1396
  • [8] COPD in HIV-Infected Patients: CD4 Cell Count Highly Correlated
    Risso, Karine
    Guillouet-de-Salvador, Francine
    Valerio, Laure
    Pugliese, Pascal
    Naqvi, Alissa
    Durant, Jacques
    Demonchy, Elisa
    Perbost, Isabelle
    Cue, Eric
    Marquette, Charles-Hugo
    Roger, Pierre-Marie
    [J]. PLOS ONE, 2017, 12 (01):
  • [9] Analysis of treatment for HIV-infected patients considering CD4 T cell count in STI
    Park, Ki Yeon
    Chung, Han Byul
    Chung, Chung Choo
    [J]. 2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 3382 - +
  • [10] Is the CD4 cell percentage a better marker of immunosuppression than the absolute CD4 cell count in HIV-infected patients with cirrhosis?
    Bongiovanni, Marco
    Gori, Andrea
    Lepri, Alessandro Cozzi
    Antinori, Andrea
    de Luca, Andrea
    Pagano, Gabriella
    Chiodera, Alessandro
    Puoti, Massimo
    Monforte, Antonella d'Arminio
    [J]. CLINICAL INFECTIOUS DISEASES, 2007, 45 (05) : 650 - 653