Custom-made antibiotic cement nails: A comparative study of different fabrication techniques

被引:31
|
作者
Kim, Ji Wan [2 ]
Cuellar, Derly O. [1 ]
Hao, Jiandong [1 ]
Seligson, David [3 ]
Mauffrey, Cyril [1 ]
机构
[1] Univ Colorado, Sch Med, Dept Orthopaed, Denver Hlth Med Ctr, Denver, CO 80204 USA
[2] Inje Univ, Coll Med, Haeundae Paik Hosp, Dept Orthopaed Surg, Pusan 612862, South Korea
[3] Univ Hosp Louisville, Dept Orthopaed, Louisville, KY 40202 USA
关键词
Osteomyelitis; Intramedullary infection; Antibiotic cement nails; SEGMENTAL BONE DEFECTS; INFECTED NONUNION; INTRAMEDULLARY INFECTIONS; BEAD CHAINS; LONG BONES; MANAGEMENT; TIBIA; FRACTURES; ELUTION; HIP;
D O I
10.1016/j.injury.2014.03.006
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The management of intramedullary long bone infections remains a challenge. Placement of antibiotic cement nails is a useful adjuvant to the antibiotic treatment of osteomyelitis. However, fabrication of antibiotic cement nails can be arduous. The purpose of this article is to introduce an easy and reproducible technique for the fabrication of antibiotics cement nails. Materials and methods: We compared the time required to peel the chest tube off the 6 antibiotic cement nail using 2 different cement-cooling techniques and the addition of mineral oil in the chest tube. Additionally, we evaluated the optimal time to cut the chest tube (before and after cement hardening), consistency of nail's diameter, and the roughness of its surface. Cooling and peeling times were measured and failure was defined as a working time (from cement mixing to have a usable antibiotic cement nail) that exceeded 1 h. Results: When the antibiotic cement nail was left to cool by convection (i.e. air-cooling), we failed to peel the plastic off the cement nail. When the chest tube was cut after conductive cooling (i.e. cold water-cooled), the cooling time was 10 min and the peeling time was 30 min without the use of mineral oil; the addition of mineral oil reduced peeling time to 7.5 min. Following peeling, residual adherent plastic pieces were found along the entire surface of the nail when no mineral oil was used. This was rarely seen when mineral oil was utilized to coat the inner layer of the chest tube. Conclusion: Conductively cooling of the cement nail (in cold water) and pre-lubricating the chest tube with mineral oil are 2 tricks that render fabrication of antibiotic nail more efficient, reliable, and practical. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1179 / 1184
页数:6
相关论文
共 50 条
  • [1] Custom-Made Antibiotic Cement Nails in Orthopaedic Trauma: Review of Outcomes, New Approaches, and Perspectives
    Wasko, Marcin K.
    Kaminski, Rafal
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [2] The effectiveness of antibiotic cement-coated nails in post-traumaticfemoral and tibial osteomyelitis - comparative analysis of custom-made versuscommercially available nails
    Garabano, German
    del Sel, Hernan
    Rodriguez, Joaquin Anibal
    Perez Alamino, Leonel
    Pesciallo, Cesar Angel
    [J]. JOURNAL OF BONE AND JOINT INFECTION, 2021, 6 (09) : 457 - 466
  • [3] Antibiotic cement-coated rigid locked nails in infected femoral and tibial nonunion. Reoperation rates of commercial versus custom-made nails
    Lu, Zhen-liang
    Lu, Ke
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (11):
  • [4] Antibiotic cement-coated rigid locked nails in infected femoral and tibial nonunion. Reoperation rates of commercial versus custom-made nails
    Garabano, German
    Pereira, Sebastian
    Perez Alamino, Leonel
    Alzate Munera, Mateo
    Ernst, Glenda
    Bidolegui, Fernando
    Angel Pesciallo, Cesar
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54
  • [5] PROPERTIES OF CUSTOM-MADE PLASTIC TEETH FORMED BY DIFFERENT TECHNIQUES
    MARTINS, EA
    PEYTON, FA
    KINGERY, RH
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1962, 12 (06): : 1059 - &
  • [6] Custom-Made Antibiotic Cement-Coated Nail for the Treatment of Infected Bone Defect
    Wang, Guoliang
    Luo, Wen
    Zhou, Yong
    Zhu, Zhenfeng
    Zhao, Zihou
    Liu, Shiyu
    Li, Jing
    Feng, Xuebin
    Zheng, Yao
    Liang, Jiahe
    Yi, Jiangpu
    Zhang, Yong
    Zhang, Yunfei
    [J]. BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [7] Design and fabrication of custom-made dental implants
    Xianshuai Chen
    Longhan Xie
    Jianyu Chen
    R. Du
    Feilong Deng
    [J]. Journal of Mechanical Science and Technology, 2012, 26 : 1993 - 1998
  • [8] Design and fabrication of custom-made dental implants
    Chen, Xianshuai
    Xie, Longhan
    Chen, Jianyu
    Du, R.
    Deng, Feilong
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (07) : 1993 - 1998
  • [9] FABRICATION OF CUSTOM-MADE EAR PLUGS FOR SWIMMING
    KASDEN, SD
    ROBINSON, M
    [J]. ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1974, 100 (01) : 68 - 68
  • [10] The Antibiotic Immersion of Custom-Made Porous Hydroxyapatite Cranioplasty: A Multicentric Cohort Study
    Amendola, Francesco
    Vaienti, Luca
    Carbonaro, Riccardo
    Nataloni, Angelo
    Barbanera, Andrea
    Zingaretti, Nicola
    Pier, Camillo Parodi
    Zanotti, Bruno
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2022, 33 (05) : 1464 - 1468