Measurement of fugitive volatile organic compound emissions from a petrochemical tank farm using open-path Fourier transform infrared spectrometry

被引:27
|
作者
Wu, Chang-Fu [1 ,2 ,3 ]
Wu, Tzong-gang [2 ]
Hashmonay, Ram A. [4 ]
Chang, Shih-Ying [2 ]
Wu, Yu-Syuan [3 ]
Chao, Chun-Ping [5 ]
Hsu, Cheng-Ping [6 ]
Chase, Michael J. [4 ]
Kagann, Robert H. [4 ]
机构
[1] Natl Taiwan Univ, Dept Publ Hlth, Taipei 100, Taiwan
[2] Natl Taiwan Univ, Inst Environm Hlth, Taipei 100, Taiwan
[3] Natl Taiwan Univ, Inst Occupat Med & Ind Hyg, Taipei 100, Taiwan
[4] Atmosfir Opt Ltd, Raleigh, NC USA
[5] Factor Engn & Technol Corp, Taipei, Taiwan
[6] Environm Sci Corp, Taipei, Taiwan
关键词
Fugitive emission; Volatile organic compound; Storage tank; Optical remote sensing; ABSORPTION-SPECTROSCOPY; COMPOUNDS VOCS; REFINERY; TAIWAN; PLANT; AREA;
D O I
10.1016/j.atmosenv.2013.10.036
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Fugitive emission of air pollutants is conventionally estimated based on standard emission factors. The Vertical Radial Plume Mapping (VRPM) technique, as described in the US EPA OTM-10, is designed to measure emission flux by directly monitoring the concentration of the plume crossing a vertical plane downwind of the site of interest This paper describes the evaluation results of implementing VRPM in a complex industrial setting (a petrochemical tank farm). The vertical plane was constructed from five retroreflectors and an open-path Fourier transform infrared spectrometer. The VRPM configuration was approximately 189.2 m in width x 30.7 m in height. In the accompanying tracer gas experiment, the bias of the VRPM estimate was less than 2% and its 95% confidence interval contained the true release rate. Emission estimates of the target VOCs (benzene, m-xylene, o-xylene, p-xylene, and toluene) ranged from 0.86 to 2.18 g s(-1) during the 14-day field campaign, while estimates based on the standard emission factors were one order of magnitude lower, possibly leading to an underestimation of the impact of these fugitive emissions on air quality and human health. It was also demonstrated that a simplified 3-beam geometry (i.e., without one dimensional scanning lines) resulted in higher uncertainties in the emission estimates. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:335 / 342
页数:8
相关论文
共 50 条
  • [1] Source Identification of VOCs in a Petrochemical Complex by Applying Open-Path Fourier Transform Infrared Spectrometry
    Chen, Mei-Hsia
    Yuan, Chung-Shin
    Wang, Lin-Chi
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2014, 14 (06) : 1630 - U401
  • [2] Axicon as a retroreflector in open-path Fourier transform infrared spectrometry
    Richardson, RL
    Griffiths, PR
    [J]. OPTICAL ENGINEERING, 2003, 42 (08) : 2197 - 2201
  • [3] Quantifying fugitive gas emissions from an oil sands tailings pond with open-path Fourier transform infrared measurements
    You, Yuan
    Moussa, Samar G.
    Zhang, Lucas
    Fu, Long
    Beck, James
    Staebler, Ralf M.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (02) : 945 - 959
  • [4] Measurement of diffuse emissions in production-integrated environmental protection using Fourier transform infrared spectrometry with open-path monitoring
    Heise, HM
    Müller, U
    [J]. OPTISCHE ANALYSENTECHNIK IN INDUSTRIE UND UMWELT-HEUTE UND MORGEN, 2000, 1551 : 21 - 28
  • [5] Monitoring of CO flare emissions using open-path Fourier transform infrared technology
    Zwicker, JO
    Ringler, E
    Kagann, R
    [J]. ENVIRONMENTAL MONITORING AND REMEDIATION TECHNOLOGIES, 1999, 3534 : 9 - 20
  • [6] Applications of open-path Fourier transform infrared for identification of volatile organic compound pollution sources and characterization of source emission behaviors
    Lin, Chitsan
    Liou, Naiwei
    Sun, Endy
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2008, 58 (06) : 821 - 828
  • [7] Emissions from smoldering combustion of biomass measured by open-path Fourier transform infrared spectroscopy
    Yokelson, RJ
    Susott, R
    Ward, DE
    Reardon, J
    Griffith, DWT
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1997, 102 (D15) : 18865 - 18877
  • [8] A Feasible Approach to Quantify Fugitive VOCs from Petrochemical Processes by Integrating Open-Path Fourier Transform Infrared Spectrometry Measurements and Industrial Source Complex (ISC) Dispersion Model
    Chen, Mei-Hsia
    Yuan, Chung-Shin
    Wang, Lin-Chi
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (03) : 1110 - 1117
  • [9] Detecting volatile compounds in food by open-path Fourier-transform infrared spectroscopy
    Jiao, Leizi
    Guo, Yuming
    Chen, Jia
    Zhao, Xiande
    Dong, Daming
    [J]. FOOD RESEARCH INTERNATIONAL, 2019, 119 : 968 - 973
  • [10] AUTOMATED DETECTION OF METHANOL VAPOR BY OPEN-PATH FOURIER-TRANSFORM INFRARED SPECTROMETRY
    BANGALORE, AS
    SMALL, GW
    COMBS, RJ
    KNAPP, RB
    KROUTIL, RT
    [J]. ANALYTICA CHIMICA ACTA, 1994, 297 (03) : 387 - 403