Highly sensitive and selective separation of intact parathyroid hormone and variants by sheathless CE-ESI-MS/MS

被引:22
|
作者
Nyssen, Laurent [1 ,2 ]
Fillet, Marianne [2 ]
Cavalier, Etienne [1 ]
Servais, Anne-Catherine [2 ]
机构
[1] Univ Liege, CIRM, Dept Clin Chem, Liege, Belgium
[2] Univ Liege, CIRM, LAM, Liege, Belgium
关键词
CE-ESI-MS; MS; native protein; PTH; sheathless interface; variants; IONIZATION-MASS-SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; TRANSIENT ISOTACHOPHORESIS; HEMODIALYSIS-PATIENTS; PTH CONCENTRATIONS; BONE TURNOVER; RENAL-FAILURE; MS INTERFACE; PEPTIDE; ASSAYS;
D O I
10.1002/elps.201800507
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Parathyroid hormone (PTH) is a common clinical marker whose quantification relies on immunoassays, giving variable results as batch, brand, or target epitope changes. Sheathless CE-ESI-MS, combining CE resolution power and low-flow ESI sensitivity, was applied to the analysis of PTH in its native conformation in the presence of related forms. Fused silica and neutral-coated capillaries were investigated, as well as preconcentration methods such as transient isotachophoresis, field-amplified sample injection (FASI), and electrokinetic supercharging (EKS). The method for the separation of PTH and its variants was first developed using fused-silica capillary with UV detection. An acidic BGE was used to separate 1-84 PTH (full length), 7-84 PTH, and 1-34 PTH. Acetonitrile was added to the BGE to reduce peptide adsorption onto the capillary wall and transient isotachophoresis was used as analyte preconcentration method. The method was then transferred to a sheathless CE-ESI-MS instrument. When using a fused silica capillary, CE-MS was limited to mu g/mL levels. The use of a neutral coating combined with FASI or EKS allowed a significant increase in sensitivity. Under these conditions, 1-84 PTH, 7-84 PTH, and 1-34 PTH were detected at concentrations in the low ng/mL (FASI) or pg/mL (EKS) range.
引用
收藏
页码:1550 / 1557
页数:8
相关论文
共 50 条
  • [1] Highly sensitive determination of aminoglycoside residues in food by sheathless CE-ESI-MS/MS
    Yu, Yue
    Liu, Ying
    Wang, Wentao
    Jia, Yanbo
    Zhao, Guiping
    Zhang, Xinxiang
    Chen, Hongxu
    Zhou, Yinglin
    ANALYTICAL METHODS, 2019, 11 (39) : 5064 - 5069
  • [2] Development of a sheathless CE-ESI-MS interface
    Hirayama, Akiyoshi
    Abe, Hiroshi
    Yamaguchi, Nozomi
    Tabata, Sho
    Tomita, Masaru
    Soga, Tomoyoshi
    ELECTROPHORESIS, 2018, 39 (11) : 1382 - 1389
  • [3] Speciation of Aluminum by CE-ESI-MS and CE-ICP-MS
    Nakamoto, Daisuke
    Tanaka, Miho
    BUNSEKI KAGAKU, 2014, 63 (05) : 383 - 390
  • [4] CE-ESI-MS shows potential
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (09) : VII - VII
  • [5] Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE-ESI-MS coupling
    Bonvin, Gregoire
    Veuthey, Jean-Luc
    Rudaz, Serge
    Schappler, Julie
    ELECTROPHORESIS, 2012, 33 (04) : 552 - 562
  • [6] Highly sensitive CE-ESI-MS analysis of N-glycans from complex biological samples
    Guinevere S. M. Lageveen-Kammeijer
    Noortje de Haan
    Pablo Mohaupt
    Sander Wagt
    Mike Filius
    Jan Nouta
    David Falck
    Manfred Wuhrer
    Nature Communications, 10
  • [7] Direct analysis of reduced and oxidized glutathione by CE-ESI-MS/MS
    Assuncao, Nilson Antonio
    Soare, Chrislaine Oliveira
    Dominque, Olivia
    Stevanil, Cassius Vinicius
    Becharal, Etelvino Jose Henriques
    FREE RADICAL BIOLOGY AND MEDICINE, 2007, 43 : S13 - S13
  • [8] Highly sensitive CE-ESI-MS analysis of N-glycans from complex biological samples
    Lageveen-Kammeijer, Guinevere S. M.
    de Haan, Noortje
    Mohaupt, Pablo
    Wagt, Sander
    Filius, Mike
    Nouta, Jan
    Falck, David
    Wuhrer, Manfred
    NATURE COMMUNICATIONS, 2019, 10 (1)
  • [9] Complexation of metals by phytosiderophores revealed by CE-ESI-MS and CE-ICP-MS
    Dell'mour, Madeleine
    Koellensperger, Gunda
    Quirino, Joselito P.
    Haddad, Paul R.
    Stanetty, Christian
    Oburger, Eva
    Puschenreiter, Markus
    Hann, Stephan
    ELECTROPHORESIS, 2010, 31 (07) : 1201 - 1207
  • [10] Peptide characterization by CE-ESI-MS with orthogonal spray
    Serwe, M
    Ross, G
    CHROMATOGRAPHIA, 1999, 49 (Suppl 1) : S73 - S77