Carpal Tunnel Syndrome: Diagnosis by Means of Median Nerve Elasticity-Improved Diagnostic Accuracy of US with Sonoelastography

被引:84
|
作者
Miyamoto, Hideaki [1 ,4 ]
Halpern, Ethan J. [5 ]
Kastlunger, Martin [1 ]
Gabl, Markus [2 ]
Arora, Rohit [2 ]
Bellmann-Weiler, Rosa [3 ]
Feuchtner, Gudrun M. [1 ]
Jaschke, Werner R. [1 ]
Klauser, Andrea S. [1 ]
机构
[1] Med Univ Innsbruck, Clin Immunol & Infect Dis, Dept Diagnost Radiol, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Clin Immunol & Infect Dis, Dept Trauma Surg & Sports Med, A-6020 Innsbruck, Austria
[3] Med Univ Innsbruck, Clin Immunol & Infect Dis, Dept Internal Med 1, A-6020 Innsbruck, Austria
[4] Univ Tokyo, Grad Sch Med, Dept Orthopaed Surg, Tokyo, Japan
[5] Thomas Jefferson Univ, Dept Radiol, Philadelphia, PA 19107 USA
关键词
CROSS-SECTIONAL AREA; STRAIN ELASTOGRAPHY; SONOGRAPHY; COMPRESSION; LESIONS; RATIO;
D O I
10.1148/radiol.13122901
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the elasticity of the median nerve (MN) between healthy volunteers and patients with carpal tunnel syndrome (CTS) and to evaluate the diagnostic utility of sonoelastographic measurements of the elasticity of the MN. Materials and Methods: This study was performed with institutional review board approval and written informed consent from all participants. Hands in 22 healthy volunteers and in 31 patients with symptomatic CTS were studied. The cross-sectional area (CSA) and the elasticity of the MN, which was measured as the acoustic coupler (AC)/ MN strain ratio, were evaluated. Results: Both hands in 22 healthy volunteers (three men [mean age, 52.7 years; age range, 41-65 years]; 19 women [mean age, 62.2 years; age range, 40-88 years]) and 43 hands in 31 patients with symptomatic CTS (three men [mean age, 69.0 years; age range, 46-88 years]; 28 women [mean age, 61.2 years; age range, 39-92 years]) were studied. Both the AC/ MN strain ratio and the CSA in the patients with CTS were significantly higher than those in the healthy volunteers (P <.001). The presence of CTS was predicted by means of AC/ MN strain ratio and CSA cutoff values, respectively, of 4.3 and 11 mm(2), with areas under the receiver operating characteristic curves (AUCs) of 0.78 (95% confidence interval [CI]: 0.69, 0.88) and 0.85 (95% CI: 0.78, 0.93). A logistic model that combined the AC/ MN strain ratio and the CSA improved diagnostic accuracy for CTS, with an AUC of 0.91 (95% CI: 0.85, 0.97; P <.001). Conclusion: Sonoelastography provides significant improvement in the diagnostic accuracy of the ultrasonographic assessment of CTS.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [1] Ultrasonography of the Median Nerve in the Carpal Tunnel Syndrome Diagnosis
    Pertea, Mihaela
    Ursu, S.
    Ciobanu, P.
    Grosu, Oxana Madalina
    Tudor, R.
    Sirbu, P. D.
    [J]. 2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
  • [2] Diagnostic accuracy of ultrasonography in diagnosis of Carpal Tunnel Syndrome
    Shaukat, Aamir
    Aamir, Hooria
    Ahmad, Zaheer
    Ahmad, Umair
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (04) : 753 - 756
  • [3] The diagnostic accuracy of median nerve ultrasonography in elderly patients with carpal tunnel syndrome: sensitivity and specificity assessment
    Roghani, Reza Salman
    Hashemi, Seyed Ebrahim
    Holisaz, Mohammad Taghi
    Gohari, Faeze
    Delbari, Ahmad
    Lokk, Johan
    [J]. CLINICAL INTERVENTIONS IN AGING, 2018, 13 : 1953 - 1962
  • [4] Proximal Median Nerve Compression in the Differential Diagnosis of Carpal Tunnel Syndrome
    Lopponen, Pekka
    Hulkkonen, Sina
    Ryhanen, Jorma
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (14)
  • [5] Sensitivity and specificity of median nerve ultrasonography in diagnosis of carpal tunnel syndrome
    Yazdchi, Mohammad
    Tarzemani, Mohammad Kazem
    Mikaeili, Haleh
    Ayromlu, Hormoz
    Ebadi, Hooman
    [J]. INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2012, 5 : 99 - 103
  • [6] The role of ultrasonographic measurements of the median nerve in the diagnosis of carpal tunnel syndrome
    Yesildag, A
    Kutluhan, S
    Sengul, N
    Koyuncuoglu, HR
    Oyar, O
    Guler, K
    Gulsoy, UK
    [J]. CLINICAL RADIOLOGY, 2004, 59 (10) : 910 - 915
  • [7] SYNDROME OF MEDIAN NERVE COMPRESSION IN CARPAL TUNNEL
    LANG, EF
    [J]. SURGICAL CLINICS OF NORTH AMERICA, 1954, 34 (03) : 853 - 857
  • [8] Median nerve recovery in carpal tunnel syndrome
    Todnem, K
    Lundemo, G
    [J]. MUSCLE & NERVE, 2000, 23 (10) : 1555 - 1560
  • [9] MEDIAN NERVE ULTRASONOGRAPHY DIAGNOSTIC ACCURACY AND ELECTRODIAGNOSTIC EVALUATION OF CARPAL TUNNEL SYNDROME IN TYPE 2 DIABETES MELLITUS
    Draghili, Nicu Catalin
    Leucuta, Daniel-Corneliu
    Tamas, Maria Magdalena
    Lupescu, Tudor Dimitrie
    Strilciuc, Stefan
    Rednic, Simona
    Muresanu, Dafin Fior
    [J]. ACTA MEDICA MEDITERRANEA, 2020, 36 (06): : 3415 - 3420
  • [10] Ultrasonographic measurement of median nerve cross-sectional area in idiopathic carpal tunnel syndrome: Diagnostic accuracy
    Nakamichi, KI
    Tachibana, S
    [J]. MUSCLE & NERVE, 2002, 26 (06) : 798 - 803