Comparative study on methods for computing soil heat storage and energy balance in arid and semi-arid areas

被引:10
|
作者
Li Yuan [1 ]
Liu Shuhua [1 ]
Wang Shu [1 ]
Miao Yucong [1 ]
Chen Bicheng [1 ]
机构
[1] Peking Univ, Sch Phys, Dept Atmospher & Ocean Sci, Beijing 100871, Peoples R China
关键词
soil heat storage; harmonic method; conduction-convection method; temperature integral method; surface energy balance; THERMAL-DIFFUSIVITY; CLOSURE; FLUX; TEMPERATURE; TERM;
D O I
10.1007/s13351-014-3043-5
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Observations collected in the Badan Jaran desert hinterland and edge during 19-23 August 2009 and in the Jinta Oasis during 12-16 June 2005 are used to assess three methods for calculating the heat storage of the 5-20-cm soil layer. The methods evaluated include the harmonic method, the conduction-convection method, and the temperature integral method. Soil heat storage calculated using the harmonic method provides the closest match with measured values. The conduction-convection method underestimates nighttime soil heat storage. The temperature integral method best captures fluctuations in soil heat storage on sub-diurnal timescales, but overestimates the amplitude and peak values of the diurnal cycle. The relative performance of each method varies with the underlying land surface. The land surface energy balance is evaluated using observations of soil heat flux at 5-cm depth and estimates of ground heat flux adjusted to account for soil heat storage. The energy balance closure rate increases and energy balance is improved when the ground heat flux is adjusted to account for soil heat storage. The results achieved using the harmonic and temperature integral methods are superior to those achieved using the conduction-convection method.
引用
收藏
页码:308 / 322
页数:15
相关论文
共 50 条
  • [1] Comparative study on methods for computing soil heat storage and energy balance in arid and semi-arid areas
    Yuan Li
    Shuhua Liu
    Shu Wang
    Yucong Miao
    Bicheng Chen
    Journal of Meteorological Research, 2014, 28 : 308 - 322
  • [2] Comparative Study on Methods for Computing Soil Heat Storage and Energy Balance in Arid and Semi-Arid Areas
    李源
    刘树华
    王姝
    缪育聪
    陈笔澄
    Journal of Meteorological Research, 2014, 28 (02) : 308 - 322
  • [3] Comparative performance of soil water balance models in computing semi-arid aquifer recharge
    Touhami, I.
    Andreu, J. M.
    Chirino, E.
    Sanchez, J. R.
    Pulido-Bosch, A.
    Martinez-Santos, P.
    Moutahir, H.
    Bellot, J.
    HYDROLOGICAL SCIENCES JOURNAL, 2014, 59 (01) : 193 - 203
  • [4] A COMPARATIVE STUDY OF NITRIFICATION IN SOILS FROM ARID AND SEMI-ARID AREAS OF ISRAEL
    ETINGERT.R
    JOURNAL OF SOIL SCIENCE, 1969, 20 (02): : 307 - &
  • [5] Soil and water conservation in arid and semi-arid areas: The Chinese experience
    Li, XY
    ANNALS OF ARID ZONE, 2000, 39 (04) : 377 - 393
  • [6] Improving soil heat and moisture forecasting for arid and semi-arid regions: A comparative study of four mathematical algorithms
    Yang, Junjun
    Feng, Jianmin
    He, Zhibin
    ARID LAND RESEARCH AND MANAGEMENT, 2018, 32 (02) : 149 - 169
  • [7] Evapotranspiration retrieval in Arid and Semi-Arid Areas
    Li, Qin
    Chen, Xi
    Bao, Anming
    PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING (ICEESD2011), PTS 1-5, 2012, 356-360 : 2307 - +
  • [8] LEGUME TREES IN SEMI-ARID AND ARID AREAS
    FELKER, P
    PESQUISA AGROPECUARIA BRASILEIRA, 1984, 19 : 47 - 59
  • [9] Study of Streptomyces Diversity in Arid and Semi-Arid Soil of India
    Shanker, Nikhil
    Vikram, Nitin
    Tyagi, Abhishek
    Gabrani, Reema
    Sarethy, Indira P.
    JOURNAL OF PURE AND APPLIED MICROBIOLOGY, 2010, 4 (02): : 687 - 699
  • [10] Effects of the soil heat flux estimates on surface energy balance closure over a semi-arid grassland
    Ping Yue
    Qiang Zhang
    Shengjie Niu
    Hua Cheng
    Xiyu Wang
    Acta Meteorologica Sinica, 2011, 25 : 774 - 782