Kinematic and kinetic analysis of the walking pattern in hemiplegic patients with foot-drop using a peroneal nerve stimulator

被引:29
|
作者
Voigt, M [1 ]
Sinkjaer, T [1 ]
机构
[1] Aalborg Univ, Ctr Sensory Motor Interact, DK-9220 Aalborg, Denmark
关键词
hemiplegic patients; foot-drop; peroneal nerve stimulator; walking speed; power profiles; bone-on-bone forces; walking efficiency;
D O I
10.1016/S0268-0033(99)00082-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To analyze the walking pattern in hemiplegic patients using a peroneal nerve stimulator to locate possible harmful mechanical effects on the musculo-skeletal system. Design. Eight hemiplegic patients participated in the study. All patients had used a peroneal nerve stimulator regularly for more than two years and were able to perform unassisted walking. Background. Peroneal nerve stimulators are widely applied for correction of foot-drop in hemiplegic patients. The stimulators do not induce normal dorsi-flexion, but a rather exaggerated dorsi-flexion and eventually eversion which might be harmful. Methods. Three-dimensional kinematic and kinetic analyses of the walking patterns at self-selected speeds were performed with the patients walking without the stimulator and with the stimulator turned on. Results. The walking speed increased on average from 0.77 (S.D., 0.83) to 0.84 (S.D., 0.11) (7.6%, P = 0.005) when the stimulator was used, however no uniform changes in the walking pattern and joint loads were observed. The total work (generation + absorption) produced by the affected leg (both with and without the peroneal nerve stimulator) was significantly lower (P = 0.005) than that of the contralateral leg. Deviations from normal power profiles were observed both on the affected and the contralateral side, and the walking efficiency was 57% lower compared to normal subjects. The estimated peak bone-on-bone forces corresponded to about 50% of what previously has been observed during normal walking at self-selected speed. Conclusions. The use of the peroneal nerve stimulator do not introduce any excessive and potential harmful mechanical loads.
引用
收藏
页码:340 / 351
页数:12
相关论文
共 50 条
  • [1] Clinical application of peroneal nerve stimulator system using percutaneous intramuscular electrodes for correction of foot drop in hemiplegic patients
    Shimada, Yoichi
    Matsunaga, Toshiki
    Misawa, Akiko
    Ando, Shigeru
    Itoi, Eiji
    Konishi, Natsuo
    [J]. NEUROMODULATION, 2006, 9 (04): : 320 - 327
  • [2] PERONEAL NERVE STIMULATOR IN REHABILITATION OF HEMIPLEGIC PATIENTS
    TAKEBE, K
    KUKULKA, C
    NARAYAN, MG
    MILNER, M
    BASMAJIAN, JV
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1975, 56 (06): : 237 - 240
  • [3] Does a foot-drop implant improve kinetic and kinematic parameters in the foot and ankle?
    Kiriakos Daniilidis
    Eike Jakubowitz
    Anna Thomann
    Sarah Ettinger
    Christina Stukenborg-Colsman
    Daiwei Yao
    [J]. Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 499 - 506
  • [4] Does a foot-drop implant improve kinetic and kinematic parameters in the foot and ankle?
    Daniilidis, Kiriakos
    Jakubowitz, Eike
    Thomann, Anna
    Ettinger, Sarah
    Stukenborg-Colsman, Christina
    Yao, Daiwei
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (04) : 499 - 506
  • [5] Spatiotemporal, Kinematic, and Kinetic Effects of a Peroneal Nerve Stimulator Versus an Ankle Foot Orthosis in Hemiparetic Gait
    Sheffler, Lynne R.
    Bailey, Stephanie Nogan
    Wilson, Richard D.
    Chae, John
    [J]. NEUROREHABILITATION AND NEURAL REPAIR, 2013, 27 (05) : 403 - 410
  • [6] TREATMENT OF DROP FOOT USING AN IMPLANTABLE PERONEAL UNDERKNEE STIMULATOR
    STROJNIK, P
    ACIMOVIC, R
    VAVKEN, E
    SIMIC, V
    STANIC, U
    [J]. SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1987, 19 (01): : 37 - 43
  • [7] Application of a dual channel peroneal nerve stimulator in a patient with a "central" drop foot
    van der Aa, HE
    Bultstra, G
    Verloop, AJ
    Kenney, L
    Holsheimer, J
    Nene, A
    Hermens, HJ
    Zilvold, G
    Buschman, HPJ
    [J]. FUNCTIONAL REHABILITATION IN NEUROSURGERY AND NEUROTRAUMATOLOGY, 2002, 79 : 105 - 107
  • [8] Inverse Kinetic and Kinematic Analysis of Drop-Foot Patient's Walking
    Matinmanesh, Ali
    Mallakzadeh, Mohammadreza
    [J]. 2011 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2011,
  • [9] Kinematic and kinetic benefits of implantable peroneal nerve stimulation in people with post-stroke drop foot using an ankle-foot orthosis
    Berenpas, Frank
    Schiemanck, Sven
    Beelen, Anita
    Nollet, Frans
    Weerdesteyn, Vivian
    Geurts, Alexander
    [J]. RESTORATIVE NEUROLOGY AND NEUROSCIENCE, 2018, 36 (04) : 547 - 558