Transient viscous response of the human cornea probed with the Surface Force Apparatus

被引:10
|
作者
Zappone, Bruno [1 ]
Patill, Navinkumar J. [2 ]
Lombardo, Marco [3 ]
Lombardo, Giuseppe [4 ]
机构
[1] CNR, Ist Nanotecnol CNR Nanotec, Arcavacata Di Rende, CS, Italy
[2] Univ Calabria, Dipartimento Fis, Arcavacata Di Rende, CS, Italy
[3] Vis Engn Italy Srl, Rome, Italy
[4] CNR, Ist Proc Chim Fis CNR IPCF, Messina, Italy
来源
PLOS ONE | 2018年 / 13卷 / 05期
关键词
CROSS-LINKING; UNCONFINED COMPRESSION; INTRAOCULAR-PRESSURE; BIOMECHANICAL PROPERTIES; MECHANICAL-PROPERTIES; ARTICULAR-CARTILAGE; MATERIAL PARAMETERS; STRESS-RELAXATION; STROMA; INDENTATION;
D O I
10.1371/journal.pone.0197779
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Knowledge of the biomechanical properties of the human cornea is crucial for understanding the development of corneal diseases and impact of surgical treatments (e.g., corneal laser surgery, corneal cross-linking). Using a Surface Force Apparatus we investigated the transient viscous response of the anterior cornea from donor human eyes compressed between macroscopic crossed cylinders. Corneal biomechanics was analyzed using linear viscoelastic theory and interpreted in the framework of a biphasic model of soft hydrated porous tissues, including a significant contribution from the pressurization and viscous flow of fluid within the corneal tissue. Time-resolved measurements of tissue deformation and careful determination of the relaxation time provided an elastic modulus in the range between 0.17 and 1.43 MPa, and fluid permeability of the order of 10(-13) m(4)/(N.s). The permeability decreased as the deformation was increased above a strain level of about 10%, indicating that the interstitial space between fibrils of the corneal stromal matrix was reduced under the effect of strong compression. This effect may play a major role in determining the observed rate-dependent non-linear stress-strain response of the anterior cornea, which underlies the shape and optical properties of the tissue.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Self-assembled monolayers on mercury probed in a modified surface force apparatus
    Clasohm, Lucy Y.
    Chen, Miao
    Knoll, Wolfgang
    Vinogradova, Olga I.
    Horn, Roger G.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (51): : 25931 - 25940
  • [2] FORCE FEEDBACK SURFACE FORCE APPARATUS - PRINCIPLES OF OPERATION
    STEWART, AM
    PARKER, JL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (12): : 5626 - 5633
  • [3] THE ETIOLOGY OF TRANSIENT ENDOTHELIAL CHANGES IN THE HUMAN CORNEA
    HOLDEN, BA
    WILLIAMS, L
    ZANTOS, SG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1985, 26 (10) : 1354 - 1359
  • [4] DRIVE MECHANISM FOR A SURFACE FORCE APPARATUS
    LUESSE, C
    VANALSTEN, J
    CARSON, G
    GRANICK, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (05): : 811 - 812
  • [5] Adhesion mechanics of the surface force apparatus
    Sridhar, I
    Johnson, KL
    Fleck, NA
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (12) : 1710 - 1719
  • [6] INTERACTIONS BETWEEN ADSORBED BLOOD-CLOTTING FACTORS PROBED AT THE NANOMETER-SCALE USING THE SURFACE FORCE APPARATUS
    HARTLEY, P
    BAILEY, AI
    LUCKHAM, PF
    BATTS, G
    NANOBIOLOGY, 1994, 3 (3-4): : 167 - 175
  • [7] Surface chemical reactions probed with scanning force microscopy
    Werts, MPL
    vanderVegte, EW
    Hadziioannou, G
    LANGMUIR, 1997, 13 (19) : 4939 - 4942
  • [8] The viscous force and torque on a closed irrotational surface
    Sader, John E.
    Pullin, D. I.
    JOURNAL OF FLUID MECHANICS, 2024, 987
  • [9] PHARMACOKINETICS OF SURFACE ANESTHETICS IN THE HUMAN CORNEA
    MATSUMOTO, S
    HAYASHI, K
    TSUCHISAKA, H
    ARAIE, M
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 1981, 25 (03) : 335 - 340
  • [10] MicroMegascope based dynamic surface force apparatus
    Laine, Antoine
    Jubin, Laetitia
    Canale, Luca
    Bocquet, Lyderic
    Siria, Alessandro
    Donaldson, Stephen H., Jr.
    Nigues, Antoine
    NANOTECHNOLOGY, 2019, 30 (19)