Maximum Velocity Estimation in Coronary Arteries Using 3-D Tracking Doppler

被引:6
|
作者
Fiorentini, Stefano [1 ]
Saxhaug, Lars Molgaard [1 ]
Bjastad, Tore Gruner [1 ,2 ]
Holte, Espen [1 ]
Torp, Hans [1 ]
Avdal, Jorgen [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7491 Trondheim, Norway
[2] InPhase Solut AS, N-7037 Trondheim, Norway
关键词
Coronary flow imaging; Doppler effect; high frame-rate imaging; pulsed wave Doppler; sonogram; time-frequency analysis; transit-time broadening; ultrasonic imaging; TRANSTHORACIC DOPPLER; ULTRASOUND; ECHOCARDIOGRAPHY; STENOSES; FIELDS;
D O I
10.1109/TUFFC.2018.2827241
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Several challenges currently prevent the use of Doppler echocardiography to assess blood flow in the coronary arteries. Due to the anatomy of the coronary tree, out-of-plane flow and high beam-to-flow angles easily occur. Transit-time broadening in regions with high velocities leads to overestimation of the maximum velocity envelope, which is a standard clinical parameter for flow quantification. In this paper, a commercial ultrasound system was locally modified to perform trans-thoracic, 3-D high frame-rate imaging of the coronary arteries. The imaging sequence was then combined with 3-D tracking Doppler for retrospective estimation of maximum velocities. Results from simulations showed that 3-D tracking Doppler delivers sonograms with better velocity resolution and spectral SNR compared to conventional pulsed wave (PW) Doppler. Results were confirmed using in vitro recordings. Further simulations based on realistic coronary flow data showed that 3-D tracking Doppler can provide improved performance compared to PW Doppler, suggesting a potential benefit to patients. In vivo feasibility of the method was also shown in a healthy volunteer.
引用
收藏
页码:1102 / 1110
页数:9
相关论文
共 50 条
  • [1] Automatic 3-D tubular centerline tracking of coronary arteries in coronary computed tomographic angiography
    Salehi, Nasrin
    Naghsh-Nilchi, Ahmad Reza
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2018, 6 (02): : 170 - 181
  • [2] 3D tracking Doppler for quantitative blood flow assessment of coronary arteries
    Fiorentini, Stefano
    Saxhaug, Lars
    Bjastad, Tore
    Holte, Espen
    Torp, Hans
    Avdal, Jorgen
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [3] 3D tracking Doppler for improved quantitative blood flow assessment of coronary arteries
    Fiorentini, Stefano
    Saxhaug, Lars
    Bjastad, Tore
    Holte, Espen
    Torp, Hans
    Avdal, Jorgen
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [4] IMPROVED BLOOD VELOCITY ESTIMATION USING THE MAXIMUM DOPPLER FREQUENCY
    TORTOLI, P
    GUIDI, G
    NEWHOUSE, VL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (04): : 527 - 532
  • [5] L3D-OTVE: LiDAR-Based 3-D Object Tracking and Velocity Estimation Using LiDAR Odometry
    Thakur, Abhishek
    Rajalakshmi, P.
    [J]. IEEE SENSORS LETTERS, 2024, 8 (07)
  • [6] Selection of optimal phase for 3-D computed tomography reconstruction of coronary arteries using an automatic vessel tracking system
    Bush, D
    Lardo, AC
    Lima, JA
    Shapiro, EP
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 329A - 329A
  • [7] An Automatic 3-D Reconstruction of Coronary Arteries by Stereopsis
    Cetin, Mufit
    Iskurt, Ali
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2016, 40 (04) : 1 - 11
  • [8] An Automatic 3-D Reconstruction of Coronary Arteries by Stereopsis
    Mufit Cetin
    Ali Iskurt
    [J]. Journal of Medical Systems, 2016, 40
  • [9] TRACKING FACILITATES 3-D MOTION ESTIMATION
    FERMULLER, C
    ALOIMONOS, Y
    [J]. BIOLOGICAL CYBERNETICS, 1992, 67 (03) : 259 - 268
  • [10] 3-D tracking and motion estimation using hierarchical Kalman filter
    Jung, SK
    Wohn, KY
    [J]. IEE PROCEEDINGS-VISION IMAGE AND SIGNAL PROCESSING, 1997, 144 (05): : 293 - 298