Enhanced interferometric detection in two-dimensional spectroscopy with a Sagnac interferometer

被引:18
|
作者
Courtney, Trevor L. [1 ]
Park, Samuel D. [1 ]
Hill, Robert J. [1 ]
Cho, Byungmoon [1 ]
Jonas, David M. [1 ]
机构
[1] Univ Colorado, Dept Chem & Biochem, Boulder, CO 80309 USA
基金
美国国家科学基金会;
关键词
FOURIER-TRANSFORM SPECTROSCOPY; ELECTRONIC SPECTROSCOPY; PULSE-COMPRESSION; PHASE; PROBE; SPECTRA; MIRRORS;
D O I
10.1364/OL.39.000513
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An intrinsically phase-stable Sagnac interferometer is introduced for optimized interferometric detection in partially collinear two-dimensional (2D) spectroscopy. With a pump-pulse pair from an actively stabilized Mach-Zehnder interferometer, the Sagnac scheme is demonstrated in broadband, short-wave IR (1-2 mu m), 2D electronic spectroscopy of IR-26 dye. (C) 2014 Optical Society of America
引用
收藏
页码:513 / 516
页数:4
相关论文
共 50 条
  • [1] Sagnac Interferometer for Two-Dimensional Spectroscopy in the Pump-Probe Geometry
    Park, Samuel D.
    Courtney, Trevor L.
    Baranov, Dmitry
    Cho, Byungmoon
    Jonas, David M.
    [J]. ULTRAFAST PHENOMENA XIX, 2015, 162 : 428 - 431
  • [2] Optical two-dimensional Fourier transform spectroscopy with active interferometric stabilization
    Zhang, TH
    Borca, CN
    Li, XQ
    Cundiff, ST
    [J]. OPTICS EXPRESS, 2005, 13 (19): : 7432 - 7441
  • [3] TWO-DIMENSIONAL RAMAN-SPECTROSCOPY DETECTION
    FORREST, GT
    [J]. LASER FOCUS-ELECTRO-OPTICS, 1987, 23 (06): : 160 - &
  • [4] Sagnac interferometer for photothermal deflection spectroscopy
    Shiokawa, Naoyuki
    Mizuno, Yuki
    Tsuchiya, Harumasa
    Tokunaga, Eiji
    [J]. OPTICS LETTERS, 2012, 37 (13) : 2655 - 2657
  • [5] FEMTOSECOND SAGNAC INTERFEROMETER FOR PHASE SPECTROSCOPY
    MISAWA, K
    KOBAYASHI, T
    [J]. OPTICS LETTERS, 1995, 20 (14) : 1550 - 1552
  • [6] Plasmon-enhanced Raman spectroscopy of two-dimensional semiconductors
    Rahaman, Mahfujur
    Zahn, Dietrich R. T.
    [J]. JOURNAL OF PHYSICS-CONDENSED MATTER, 2022, 34 (33)
  • [7] Detection limit of Sagnac's interferometer
    Palma-Vargas, Salvador
    Sandoval-Romero, G. Eduardo
    Ibarra, Angelica Ramirez
    [J]. SIXTH SYMPOSIUM: OPTICS IN INDUSTRY, 2007, 6422
  • [8] Sagnac interferometer with adaptive nonlinear detection
    Bortolozzo, U.
    Residori, S.
    Rubin, J. L.
    Huignard, J. P.
    [J]. OPTICS LETTERS, 2011, 36 (04) : 520 - 522
  • [9] Two-dimensional regression for interferometric phase extraction
    Yu, EX
    Cha, SS
    [J]. APPLIED OPTICS, 1998, 37 (08): : 1370 - 1376
  • [10] Two-dimensional Mirrored Interferometric Aperture Synthesis
    Chen, Liangbing
    Zhang, Xiaoyun
    [J]. 2012 10TH INTERNATIONAL SYMPOSIUM ON ANTENNAS, PROPAGATION & EM THEORY (ISAPE), 2012, : 482 - 485