Diagnostic value of core biopsy histology and cytology sampling of mediastinal lymph nodes using 21-gauge EBUS-TBNA needle

被引:10
|
作者
Vaidya, Preyas J. [1 ,2 ]
Sahal, Avinandan [1 ]
Kate', Arvind H. [1 ,2 ]
Pandeyl, Kamlesh [1 ,2 ]
Chavhanl, Vinod B. [1 ,2 ]
Leuppi, Joerg D. [1 ]
Chhajed, Prashant N. [1 ,2 ]
机构
[1] Inst Pulmonol Med Res & Dev, Bombay, Maharashtra, India
[2] Fortis Hiranandani Hosp, Lung Care & Sleep Ctr, Navi Mumbai, Maharashtra, India
关键词
Biopsy; cytology; ebus tbna; endobronchial ultrasound; histology; lymph node; ENDOBRONCHIAL-ULTRASOUND; LUNG-CANCER; HILAR LYMPHADENOPATHY; CELL BLOCKS; ASPIRATION; FORCEPS; ADENOPATHY; REGISTRY; SAFETY;
D O I
10.4103/0973-1482.197535
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the initial modality of choice in sampling mediastinal lymphadenopathy. It is possible to obtain both cytological and histological samples using both 21-gauge and 22-gauge EBUS-TBNA needles. The current study was undertaken to compare the diagnostic yield of cytology and histology samples obtained by the same EBUS-TBNA 21-gauge needle. Patients and Methods: One hundred sixty-six consecutive patients who underwent EBUS-TBNA with a 21 -gauge EBUS-TBNA needle over a period of 3 years were included in this retrospective analysis. The diagnostic yields of EBUS-TBNA histology (EBUS-TBNA-H) and EBUS-TBNA cytology (EBUS-TBNA-C) specimens were compared using the McNemar test. Results: The overall sensitivity and specificity of EBUS-TBNA were 89% and 100%, respectively. The positive predictive value (PPV) and negative predictive value (NPV) of EBUS-TBNA were 100% and 53%, respectively. The overall sensitivity and specificity of EBUS-TBNA-H were 85% and 100%, respectively. The PPV and NPV of EBUS-TBNA-H were 100% and 43%, respectively. The overall sensitivity and specificity of EBUS-TBNA-C were 65% and 100%, respectively. The PPV and NPV of EBUS-TBNA-C were 100% and 14%, respectively. The diagnostic yield of EBUS-TBNA-H over EBUS-TBNA-C was statistically significant (P < 0.0001). Conclusion: EBUS-TBNA-H with 21-gauge needle significantly improves the diagnostic yield of EBUS-TBNA. EBUS-TBNA-H improves the NPV of EBUS-TBNA. The combination of EBUS-TBNA-H and EBUS-TBNA-C improves the overall diagnostic yield of EBUS-TBNA.
引用
收藏
页码:1172 / 1177
页数:6
相关论文
共 45 条
  • [1] The diagnostic value of EBUS-TBNA for small mediastinal and hilar lymph nodes.
    Pathirana, Upul
    Rodrigo, Damith
    Morjaria, Jaymin
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [2] Pneumomediastinum following endobronchial ultrasound and transbronchial needle aspirate (EBUS-TBNA) sampling of mediastinal lymph nodes
    Stanton, Alice
    Conroy, Kevin
    Miller, Graham
    [J]. BMJ CASE REPORTS, 2021, 14 (08)
  • [3] Lymph node core retrieval comparison between 22 and 21 gauge EBUS-TBNA needle
    Chhajed, Prashant
    Sandeep, H. S.
    Chaudhari, Parag
    Gandhi, Sejal
    Tikare, Ramesh
    Leuppi, Joerg
    Kate, Arvind
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [4] Accidental fracture of EBUS-TBNA needle during sampling of an enlarged mediastinal lymph node
    Tariq, Syed Mohammad
    [J]. OXFORD MEDICAL CASE REPORTS, 2016, (04): : 59 - 61
  • [5] The Diagnostic Yield of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration (EBUS-TBNA) Technique in Assessment of Mediastinal Lymph Nodes
    Shahab Rafieian
    Reza Ershadi
    Hossein Ebrahimpoor
    Matin Vahedi
    [J]. SN Comprehensive Clinical Medicine, 5 (1)
  • [6] The Diagnostic Utility of Real-Time EBUS-TBNA for Hilar and Mediastinal Lymph Nodes in Conventional TBNA Negative Patients
    Cetinkaya, Erdogan
    Ozgul, M. Akif
    Tutar, Nuri
    Ozgul, Guler
    Cam, Ertan
    Bilaceroglu, Senna
    [J]. ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 20 (02) : 106 - 112
  • [7] Improving Negative Predictive Value of Endobronchial Ultrasound Guided Transbronchial Needle Aspiration (EBUS-TBNA) Staging of Mediastinal Lymph Nodes
    Marshall, C. B.
    Jacob, B.
    Stewart, J.
    [J]. LABORATORY INVESTIGATION, 2010, 90 : 100A - 100A
  • [8] Improving Negative Predictive Value of Endobronchial Ultrasound Guided Transbronchial Needle Aspiration (EBUS-TBNA) Staging of Mediastinal Lymph Nodes
    Marshall, C. B.
    Jacob, B.
    Stewart, J.
    [J]. MODERN PATHOLOGY, 2010, 23 : 100A - 100A
  • [9] EBUS-TBNA Cytology of PET Positive Verse PET Negative Lymph Nodes. A Retrospective Study with Histology Correlation
    Zheng, R.
    Yung, R.
    Clark, D.
    Li, Q. K.
    [J]. MODERN PATHOLOGY, 2010, 23 : 109A - 109A
  • [10] EBUS-TBNA Cytology of PET Positive Verse PET Negative Lymph Nodes. A Retrospective Study with Histology Correlation
    Zheng, R.
    Yung, R.
    Clark, D.
    Li, Q. K.
    [J]. LABORATORY INVESTIGATION, 2010, 90 : 109A - 109A