Novel deep learning-based CT synthesis algorithm for MRI-guided PET attenuation correction in brain PET/MR imaging

被引:0
|
作者
Arabi, Hossein [1 ]
Zeng, Guodong [2 ]
Zheng, Guoyan [2 ]
Zaidi, Habib [1 ,3 ,4 ]
机构
[1] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[2] Univ Bern, Inst Surg Technol & Biomech, CH-3014 Bern, Switzerland
[3] Neurosci Ctr, CH-1205 Geneva, Switzerland
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
基金
瑞士国家科学基金会;
关键词
GENERATION;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
MRI-guided synthetic CT (sCT) generation is one of the main challenges hampering quantitative PET/MR imaging as well as MRI-only radiation planning. Deep learning-based approaches have recently gained momentum in a variety of medical imaging applications. In this work, a novel synthetic CT generation algorithm based on deep convolutional neural network is proposed for MRI-guided attenuation correction in PET/MRI. The proposed algorithm (AsCT) exploits adversarial semantic structure learning implemented as a CT segmentation approach to constrain the adversarial synthetic CT generation process. The proposed technique was trained using 50 pairs of CT and MR brain scans under a two-fold1 cross validation scheme. The AsCT method was compared to an atlas-based method (Bone-Atl), previously developed for MRI-only radiation planning, as well as the commercial segmentation-based approach (2-class) implemented on the Philips TF PET/MRI system. The evaluation was performed using clinical brain studies of 40 patients who have undergone PET/CT and MRI scanning. The accuracy of the CT value estimation and cortical bone identification were assessed for the three different methods taking CT images as reference. Bias of tracer uptake (SUV) was measured on attenuation corrected PET images using the three techniques taking CT-based attenuation corrected PET as reference. Bone-Atl and AsCT exhibited similar cortical bone extraction (using an intensity threshold of 600 Hounsfield Unit (HU)) resulting in Dice coefficient (DSC) of 0.78 +/- 0.07 and 0.77 +/- 0.07, respectively. Bone-Atl method performed slightly better in terms of accuracy of CT value estimation where a mean absolute error of 123 +/- 40 (HU) was obtained for the whole head region while AsCT and 2-class methods led to 141 +/- 40 and 230 +/- 33 (HU), respectively. Quantitative analysis of brain PET images demonstrated competitive performance of AsCT and Bone-Atl methods where mean relative errors of 1.2 +/- 13.8% and 1.0 +/- 9.9% were achieved in bony structures, respectively, while the 2-class approach led to a mean SUV error of -14.7 +/- 8.9%. The proposed AsCT algorithm showed competitive performance with respect to the atlas-based method and outperformed the segmentation-based (2-class) method with clinically tolerable errors.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Novel adversarial semantic structure deep learning for MRI-guided attenuation correction in brain PET/MRI
    Arabi, Hossein
    Zeng, Guodong
    Zheng, Guoyan
    Zaidi, Habib
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (13) : 2746 - 2759
  • [2] Novel adversarial semantic structure deep learning for MRI-guided attenuation correction in brain PET/MRI
    Hossein Arabi
    Guodong Zeng
    Guoyan Zheng
    Habib Zaidi
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2019, 46 : 2746 - 2759
  • [3] Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging
    Liu, Fang
    Jang, Hyungseok
    Kijowski, Richard
    Bradshaw, Tyler
    McMillan, Alan B.
    [J]. RADIOLOGY, 2018, 286 (02) : 676 - 684
  • [4] Comparison of MRI-guided attenuation correction strategies in PET/MRI
    Arabi, Hossein
    Rager, Olivier
    Alem, Asma
    Varoquaux, Arthur
    Becker, Minerva
    Zaidi, Habib
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [5] MRI-guided attenuation correction in torso PET/MRI: Assessment of segmentation-, atlas-, and deep learning-based approaches in the presence of outliers
    Arabi, Hossein
    Zaidi, Habib
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (02) : 686 - 701
  • [6] Deep learning-based attenuation correction for brain PET with various radiotracers
    Fumio Hashimoto
    Masanori Ito
    Kibo Ote
    Takashi Isobe
    Hiroyuki Okada
    Yasuomi Ouchi
    [J]. Annals of Nuclear Medicine, 2021, 35 : 691 - 701
  • [7] Deep learning-based attenuation correction for brain PET with various radiotracers
    Hashimoto, Fumio
    Ito, Masanori
    Ote, Kibo
    Isobe, Takashi
    Okada, Hiroyuki
    Ouchi, Yasuomi
    [J]. ANNALS OF NUCLEAR MEDICINE, 2021, 35 (06) : 691 - 701
  • [8] Brain PET-MR attenuation correction with deep learning
    Yaakub, S. N.
    McGinnity, C. J.
    Beck, K.
    Merida, I.
    Dunston, E.
    Muffoletto, M.
    Qureshi, A.
    Bhattacharya, S.
    MacKewn, J.
    Hammers, A.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 : 600 - 601
  • [9] MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging
    Izquierdo-Garcia, David
    Catana, Ciprian
    [J]. PET CLINICS, 2016, 11 (02) : 129 - +
  • [10] CT Based Attenuation Correction for PET Brain Imaging
    Lokitz, Stephen J.
    Coleman, R. Edward
    Yoshizumi, Terry T.
    Toncheva, Greta I.
    Daigle, Lauren T.
    Colsher, James G.
    Turkington, Timothy G.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3320 - 3325