Novel fluorescent oxygen indicator for intracellular oxygen measurements

被引:38
|
作者
Ji, J
Rosenzweig, N
Jones, I
Rosenzweig, Z [1 ]
机构
[1] Univ New Orleans, Dept Chem, New Orleans, LA 70148 USA
[2] Xavier Univ, Dept Chem, New Orleans, LA 70125 USA
基金
美国国家科学基金会;
关键词
D O I
10.1117/1.1483082
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Intracellular oxygen concentration is of primary importance in determining numerous physiological and pathological processes in biological systems. In this paper, we describe the application of the oxygen sensing indicator, ruthenium dibipyridine 4-(1"-pyrenyl)-2,2'-bipyridine chloride [Ru(bpy-pyr)(bpy)(2)], for molecular oxygen measurement in J774 murine macrophages. Ru(bpy-pyr)(bpy)(2) exhibits strong visible absorption, efficient fluorescence, long excited state lifetime, large Stokes shift, and high photo- and chemical stability. The fluorescence of Ru(bpy-pyr)(bpy)(2) is efficiently quenched by molecular oxygen. It is 13 fold higher in a nitrogenated solution than in an oxygenated one. The dye passively permeates into cells and maintains its oxygen sensitivity for at least 5 h when the cells are stored in a phosphate buffered saline solution at pH 7.4. The oxygen sensitivity, photostability, and chemical stability of the indicator and the effect of hypoxia and hyperoxia on the intracellular oxygen level in single macrophages are discussed. (C) 2002 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:404 / 409
页数:6
相关论文
共 50 条
  • [1] Molecular oxygen-sensitive fluorescent lipobeads for intracellular oxygen measurements in murine macrophages
    Ji, J
    Rosenzweig, N
    Jones, I
    Rosenzweig, Z
    ANALYTICAL CHEMISTRY, 2001, 73 (15) : 3521 - 3527
  • [2] Fluorescent proteins measure intracellular oxygen concentrations
    Bauer N.
    Kiefer F.
    BIOspektrum, 2023, 29 (4) : 372 - 374
  • [3] Genetic oxygen sensor: GFP as an indicator of intracellular oxygenation
    Takahashi, E
    Takano, T
    Numata, A
    Hayashi, N
    Okano, S
    Nakajima, O
    Nomura, Y
    Sato, M
    OXYGEN TRANSPORT TO TISSUE XXVI, 2005, 566 : 39 - 44
  • [4] Intracellular detection of singlet oxygen using fluorescent nanosensors
    Nath, Peuli
    Hamadna, Sameer Sayel
    Karamchand, Leshern
    Foster, John
    Kopelman, Raoul
    Amar, Jacques G.
    Ray, Aniruddha
    ANALYST, 2021, 146 (12) : 3933 - 3941
  • [5] Ratiometric Fluorescent Probes for Detection of Intracellular Singlet Oxygen
    Song, Dayoung
    Cho, Somin
    Han, Yejee
    You, Youngmin
    Nam, Wonwoo
    ORGANIC LETTERS, 2013, 15 (14) : 3582 - 3585
  • [6] Novel fluorescent probes for singlet oxygen
    Umezawa, N
    Tanaka, K
    Urano, Y
    Kikuchi, K
    Higuchi, T
    Nagano, T
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 1999, 38 (19) : 2899 - 2901
  • [7] Novel fluorescent probes for singlet oxygen
    Nagano, T
    Urano, Y
    Kikuchi, K
    Umezawa, N
    BIOPHYSICAL JOURNAL, 2000, 78 (01) : 129A - 129A
  • [8] AN INDICATOR METHOD OF ESTIMATING INTRACELLULAR OXYGEN TENSION IN RESTING MUSCLE
    COBURN, RF
    MAYERS, L
    LUOMANMA.K
    FEDERATION PROCEEDINGS, 1967, 26 (02) : 334 - &
  • [9] Fluorescent Gold Nanoprobe Sensitive to Intracellular Reactive Oxygen Species
    Lee, Hyukjin
    Lee, Kyuri
    Kim, In-Kyung
    Park, Tae Gwan
    ADVANCED FUNCTIONAL MATERIALS, 2009, 19 (12) : 1884 - 1890
  • [10] NanoSOSG: A Nanostructured Fluorescent Probe for the Detection of Intracellular Singlet Oxygen
    Ruiz-Gonzalez, Ruben
    Bresoli-Obach, Roger
    Gulias, Oscar
    Agut, Montserrat
    Savoie, Huguette
    Boyle, Ross W.
    Nonell, Santi
    Giuntini, Francesca
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2017, 56 (11) : 2885 - 2888