An alternative approach to histopathological validation of PET imaging for radiation therapy image-guidance: A proof of concept

被引:5
|
作者
Axente, Marian [1 ,2 ]
He, Jun [1 ]
Bass, Christopher P. [1 ]
Sundaresan, Gobalakrishnan [3 ]
Zweit, Jamal [3 ]
Williamson, Jeffrey F. [1 ]
Pugachev, Andrei [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Med Ctr, Richmond, VA 23284 USA
[2] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
[3] Virginia Commonwealth Univ, Med Ctr, Ctr Mol Imaging, Dept Radiol, Richmond, VA 23284 USA
关键词
PET; Histopathological validation; Small-animal imaging; Image-guidance; HUMAN GLIOMA XENOGRAFT; TUMOR MICROENVIRONMENT; SOLID TUMORS; NECK-CANCER; RAT-BRAIN; HYPOXIA; SECTIONS; PROLIFERATION; REGISTRATION; SYSTEM;
D O I
10.1016/j.radonc.2013.12.017
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In radiotherapy, PET images can be used to guide the delivery of selectively escalated doses to biologically relevant tumour subvolumes. Validation of PET for such applications requires demonstration of spatial coincidence between PET tracer uptake pattern and the histopathologically confirmed target. This study introduces a novel approach to histopathological validation of PET image segmentation for radiotherapy guidance. Methods and materials: Sequential tissue sections from surgically excised whole-tumour specimens were used to acquire full 3D-sets of both histopathological images (microscopy) and PET tracer distribution images (autoradiography). After these datasets were accurately registered, a full 3D autoradiographic distribution of PET tracer was reconstructed and used to obtain synthetic PET images (sPET) by simulating the image deterioration induced by processes involved in PET image formation. To illustrate the method, sPET images were used in this study to investigate spatial coincidence between high FDG uptake areas and the distribution of viable tissue in two small animal tumour models. Results: The reconstructed 3D autoradiographic distribution of the PET tracer was spatially coherent, as indicated by the high average value of the normalised pixel-by-pixel correlation of intensities between successive slices (0.84 +/- 0.05 and 0.94 +/- 0.02). The loss of detail in the sPET images versus the 3D autoradiography was significant as indicated by Dice coefficient values corresponding to the two turnouts (0 and 0.1 at 70% threshold). The maximum overlap between the FDG segmented volumes and the extent of the viable tissue as indicated by Dice coefficient values, was 0.8 for one tumour (for the image thresholded at 22% of max intensity) and 0.88 for the other (threshold of 14% of max intensity). Conclusion: It was demonstrated that the use of synthetic PET images for histopathological validation allows for bypassing a technically challenging and error-prone step of registering non-invasive PET images with histopathology. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:309 / 316
页数:8
相关论文
共 50 条
  • [1] Image-guidance for stereotactic body radiation therapy
    Fuss, Martin
    Boda-Heggemann, Judit
    Papanikolau, Nikos
    Salter, Bill J.
    [J]. MEDICAL DOSIMETRY, 2007, 32 (02) : 102 - 110
  • [2] IMPLEMENTATION OF IMAGE-GUIDANCE TECHNIQUES IN RADIATION THERAPY
    Thomas, Michael
    Clark, Brenda
    Macpherson, Miller
    Montgomery, Lynn
    Gerig, Lee
    [J]. ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 693 - 701
  • [3] A Novel Approach to Histopathological Validation of PET Tracers for Image Guidance in Radiotherapy
    Axente, M.
    He, J.
    Bass, C.
    Sundaresan, G.
    Zweit, J.
    Williamson, J.
    Pugachev, A.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 4011 - 4012
  • [4] Optimal Image-Guidance Frequency for Whole Breast Radiation Therapy
    Bissonnette, J. P.
    Neath, C. L.
    Hart, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E729 - E729
  • [5] Monte Carlo Study on PET Imaging Used as An Image-Guidance Tool in Very High-Energy Electron Therapy
    Bonfrate, A.
    Jones, R. M.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [6] Men's preferences for image-guidance in prostate radiation therapy: a discrete choice experiment
    Brown, Amy
    Pain, Tilley
    Anable, Lux
    Tan, Alex
    Callander, Emily
    Watt, Kerrianne
    Street, Deborah
    Lourenco, De Abreu Richard
    [J]. ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2021, 17 : 58 - 59
  • [7] Men's preferences for image-guidance in prostate radiation therapy: A discrete choice experiment
    Brown, Amy
    Pain, Tilley
    Tan, Alex
    Anable, Lux
    Callander, Emily
    Watt, Kerrianne
    Street, Deborah
    Lourenco, Richard De Abreu
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 167 : 49 - 56
  • [8] Men's preferences for image-guidance in prostate radiation therapy: a discrete choice experiment
    Brown, Amy
    Pain, Tilley
    Tan, Alex
    Anable, Lux
    Callander, Emily
    Watt, Kerrianne
    Street, Deborah
    Lourenco, Richard De Abreu
    [J]. ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2021, 17 : 141 - 141
  • [9] Development of a small animal OpenPET prototype for a proof-of-concept of PET imaging during radiation therapy
    Yamaya, Taiga
    Yoshida, Eiji
    Kinouchi, Shoko
    Suga, Mikio
    Inadama, Naoko
    Nishikido, Fumihiko
    Murayama, Hideo
    Tsuji, Atsushi
    Inaniwa, Taku
    Yoshikawa, Kyosan
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [10] MVCT image-guidance derived bony setup accuracy for supine and prone pelvic radiation therapy
    Siddiqui, F.
    Shi, C.
    Papanikolaou, N.
    Fuss, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S294 - S295