Smoke confinement utilizing the USME ventilation mode for subway station fire

被引:33
|
作者
Luo, Na [1 ]
Li, Angui [1 ]
Gao, Ran [1 ]
Tian, Zhenguo [1 ]
Hu, Zhipei [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Shaanxi, Peoples R China
基金
美国国家科学基金会;
关键词
Subway station; Ventilation modes; USME; Layout of vents; Heat release rate; CFD SIMULATION; LIFE SAFETY; EVACUATION;
D O I
10.1016/j.ssci.2014.06.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Experiment and numerical simulation were performed to research the possibility of adopting different ventilation modes for smoke confinement in a subway station fire accident. Bench scale experiments were conducted in a 1:50 scale model of a subway station. Fire Dynamics Simulator software (FDS) was utilized to carry out numerical simulations, which conducted in a full scale subway station. Experiment result agreed well with simulation result and the research showed that the different ventilation mode had different efficacy of smoke confinement released by the fire in basement 2. In addition, when the USME ventilation mode was adopted and there were smoke exhausted from basement 2 and air supplied into the basement 1, the efficacy of smoke confinement was the best. According to these cases conducted in this paper, the layouts of the ventilation vents had little influence on the efficacy of smoke confinement. Once the HRR was too big, the concentration would pass 50 PPM and the amount of exhausted smoke should be increased
引用
收藏
页码:202 / 210
页数:9
相关论文
共 50 条
  • [1] Ventilation mode analysis of exhaust smoke system for subway station fire
    Ouyang, Q
    Zhu, YX
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 4, PTS A and B, 2004, 4 : 1592 - 1596
  • [2] Numerical study on the optimisation of smoke ventilation mode for interchange subway station fire
    Zhao, Dong
    Jiang, Juncheng
    Zhou, Ru
    Tong, Yan
    Wu, Fan
    Shi, Langjun
    [J]. INTERNATIONAL JOURNAL OF VENTILATION, 2016, 15 (01) : 79 - 93
  • [3] Performance of smoke elimination and confinement with modified hybrid ventilation for subway station
    Luo, Na
    Li, Angui
    Gao, Ran
    Song, Tongyang
    Zhang, Wei
    Hu, Zhipei
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2014, 43 : 140 - 147
  • [4] Analysis and optimization of ventilation mode of exhaust smoke system in subway station fires
    Zhou, Ru
    He, Jiapeng
    Jiang, Juncheng
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1140 - 1146
  • [5] Smoke Control of Fire in Typical Subway Station
    Lu Hua
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL. VIII, PTS A AND B, 2010, 8 : 725 - 729
  • [6] A new natural ventilation method for fire-induced smoke control in a common subway station
    Wu, Fan
    Jiang, Juncheng
    Zhou, Ru
    Zhao, Dong
    Shi, Langjun
    [J]. INTERNATIONAL JOURNAL OF VENTILATION, 2018, 17 (02) : 63 - 80
  • [7] Analysis of smoke dynamic field in subway station fire
    Zhou Ru
    He Jiapeng
    Xie Juan
    Jiang Juncheng
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 823 - 826
  • [8] Fire smoke control in different structures of subway station
    Jiangsu Key Laboratory of Urban and Industrial Safety, School of Urban Construction and Safety Engineering, Nanjing University of Technology, Nanjing 210009, China
    不详
    [J]. Jiefangjun Ligong Daxue Xuebao/Journal of PLA University of Science and Technology (Natural Science Edition), 2008, 9 (06): : 681 - 686
  • [9] Minimal Ventilation velocity to Control Smoke in Subway Fire
    Wu, Wen-Zhong
    You, Shi-Jun
    [J]. 2009 INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, VOL I, 2009, : 808 - 811
  • [10] Mobile smoke ventilation equipments for subway fire ground
    Wang, LJ
    Fu, JQ
    [J]. PROCEEDINGS OF THE CHINA ASSOCIATION FOR SCIENCE AND TECHNOLOGY, VOL 1, NO 2, 2004, : 414 - 419