Design for an aberration-corrected concave grating for a mid-infrared long-slit spectrometer

被引:10
|
作者
Onaka, T [1 ]
Miyata, T
Kataza, H
Okamoto, Y
机构
[1] Univ Tokyo, Sch Sci, Dept Astron, Bunkyo Ku, Tokyo 1130033, Japan
[2] Univ Tokyo, Sch Sci, Astron Inst, Tokyo 1818588, Japan
关键词
D O I
10.1364/AO.39.001474
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new design for an aberration-corrected concave grating for the spectral region near 10 mu m is presented. It was designed for use in the ground-based astronomical medium-resolution (lambda/Delta lambda similar to 100) Mid-Infrared Camera and Spectrometer (MICS). It provides a flat focal plane for a wide spectral range (7.5-13.5 mu m) with small aberrations, permitting efficient long-slit observations in the mid-infrared region. It permits a simple design of the spectrometer without collimator and camera mirrors, which is quite advantageous for cryogenic instruments. The grating has variable spacing grooves to reduce aberrations. In addition, the grating surface figure is designed to be toroidal and in the direction perpendicular to the grooves, aspherical, to suppress the aberrations further over a wide spectral range. The angle of the grooves is also varied to yield better efficiency near the blaze angle. The grating was fabricated by high-quality ultraprecision machining, which made these features possible. Test observations confirmed that the designed spectral resolution was achieved. (C) 2000 Optical Society of America.
引用
收藏
页码:1474 / 1479
页数:6
相关论文
共 50 条
  • [1] ABERRATION-CORRECTED CONCAVE GRATING FOR THE MIDINFRARED SPECTROMETER ABOARD THE INFRARED TELESCOPE IN-SPACE
    ONAKA, T
    APPLIED OPTICS, 1995, 34 (04): : 659 - 666
  • [2] DESIGN OF AN ABERRATION-CORRECTED ELECTRON SPECTROMETER FOR THE TEM
    EGERTON, RF
    OPTIK, 1980, 57 (02): : 229 - 242
  • [3] Design of aberration-corrected flat-field holographic concave grating by parameter optimization
    Huang, Yuanshen
    Zhu, Dongyue
    Li, Baicheng
    Zhang, Dawei
    Ni, Zhengji
    Zhuang, Songlin
    OPTIK, 2012, 123 (19): : 1797 - 1800
  • [4] NORMAL INCIDENCE MONOCHROMATOR WITH AN ABERRATION-CORRECTED CONCAVE GRATING FOR SYNCHROTRON RADIATION
    ITOU, M
    HARADA, T
    KITA, T
    HASUMI, K
    KOYANO, I
    TANAKA, K
    APPLIED OPTICS, 1986, 25 (14): : 2240 - 2242
  • [5] Design of UV long-slit spectrometer
    Bazhanov, Y.
    Demura, E.
    Zacharova, N.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [6] Design and Verification of a Flat-Field Aberration-Corrected Concave Blaze Grating for Hyperspectral Imaging
    Ko, Cheng-Hao
    Tsai, Sheng-Yu
    Wu, Yueh-Hsun
    Hong, Chi-Tsung
    Tsai, Jih-Run
    Wang, Bang-Ji
    Hsiao, Chiu-Der
    OPTICAL DESIGN AND TESTING VII, 2016, 10021
  • [7] Design and Verification of a Flat-Field Aberration-Corrected Concave Blaze Grating for Hyperspectral Imaging
    Ko, Cheng-Hao
    Tsai, Sheng-Yu
    Tsai, Jih-Run
    Wang, Bang-Ji
    2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2016,
  • [8] Design and Verification of a Flat-Field Aberration-Corrected Concave Blaze Grating for Hyperspectral Imaging
    Ko, Cheng-Hao
    Tsai, Sheng-Yu
    Wu, Yueh-Hsun
    Tsai, Jih-Run
    Wang, Bang-Ji
    Lin, Shin-Fa
    Hsiao, Chiu-Der
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [9] DESIGN OF AN ABERRATION-CORRECTED ELECTRON SPECTROMETER FOR THE TEM.
    Egerton, R.F.
    Optik (Jena), 1980, 57 (02): : 229 - 242
  • [10] Design of a high-resolution extreme-ultraviolet imaging spectrometer with aberration-corrected concave gratings
    Harada, T
    Sakuma, H
    Takahashi, K
    Watanabe, T
    Hara, H
    Kita, T
    APPLIED OPTICS, 1998, 37 (28): : 6803 - 6810