Ultrasonic Active Fiber Sensor based on Pulse-echo Method

被引:4
|
作者
Lim, Seung-Hyun [1 ]
Oh, Il-Kwon [1 ]
Lee, Jung-Ryul [2 ]
机构
[1] Chonnam Natl Univ, Sch Mech Syst Engn, Kwangju 500757, South Korea
[2] Chonbuk Natl Univ, Dept Aerosp Engn, Jeonju 561756, Chonbuk, South Korea
关键词
fiber sensor; piezoelectric; ultrasonic wave; pulse-echo;
D O I
10.1177/1045389X08098769
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, the concept of the ultrasonic active fiber sensor (UAFS) system based on the pulse-echo method was newly proposed for several mechanical and environmental sensors. A piezoelectric transducer, which was attached onto the end of the optical fiber, can be used for the ultrasonic wave generator and receiver. The piezoelectric patch was excited at its resonance frequency in the direction of length to generate the longitudinal ultrasonic wave, and was used for sensing the reflected signal on the end of the optical fiber. The emitted ultrasonic wave was propagated along the optical fiber and then reflected by a mechanical stimulus on the way. The time interval of the reflected ultrasonic wave was used to predict the location of the stimulus from the piezoelectric transducer. The UAFS was applied to monitor the cure conditions and to measure liquid level. In terms of the attenuation of the ultrasonic wave by the damping properties and the degree of coupling between the surrounding medium, the cure condition of the solder was successfully monitored and the water level was measured based on the linear relationship between liquid height and output signal.
引用
下载
收藏
页码:1035 / 1043
页数:9
相关论文
共 50 条
  • [1] PULSE-ECHO ULTRASONIC FINGERPRINT SENSOR ON A CHIP
    Tang, H.
    Lu, Y.
    Fung, S.
    Tsai, J. M.
    Daneman, M.
    Horsley, D. A.
    Boser, B. E.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 674 - 677
  • [2] PULSE-ECHO ULTRASONIC TRANSDUCER CHARACTERIZATION
    ERIKSON, K
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1979, 26 (01): : 1 - 1
  • [3] ULTRASONIC PULSE-ECHO MEASUREMENTS IN TEETH
    BARBER, FE
    LEES, S
    LOBENE, RR
    ARCHIVES OF ORAL BIOLOGY, 1969, 14 (07) : 745 - &
  • [4] ULTRASONIC PULSE-ECHO ATTENUATION COMPARATOR
    HEMPHILL, RB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (01): : 175 - &
  • [5] Ultrasonic pulse-echo method to detect the faults in silicone rubber
    Gao, Y
    Liang, XD
    Niu, FQ
    Xue, JQ
    JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 425 - 428
  • [7] ECHO STRUCTURE IN MEDICAL ULTRASONIC PULSE-ECHO SCANNING
    GORE, JC
    LEEMAN, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 431 - 443
  • [8] ULTRASONIC PULSE-ECHO TECHNIQUE FOR VHF RANGE
    HEMPHILL, RB
    PENN, TC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (12): : 1809 - &
  • [9] Ultrasonic speckle pattern correlation interferometry using a pulse-echo method
    Hong, SK
    Ohr, YG
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (11) : 1392 - 1396
  • [10] ABSOLUTE ACCURACY OF PULSE-ECHO OVERLAP METHOD AND PULSE-SUPERPOSITION METHOD FOR ULTRASONIC VELOCITY
    PAPADAKIS, EP
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1972, 52 (03): : 843 - +