A Monte Carlo and measurement-based characterization of dose in stereotactic body radiation therapy (SBRT) of lung lesions: Target coverage and contralateral lung implications

被引:0
|
作者
Salter, BJ [1 ]
Rassiah, P [1 ]
Tanyi, JA [1 ]
Cheng, C [1 ]
Fuss, M [1 ]
机构
[1] Univ Texas, Hlth Sci Ctr, San Antonio, TX USA
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
2446
引用
收藏
页码:S605 / S606
页数:2
相关论文
共 50 条
  • [1] Characterization of target dose in Stereotactic Body Radiation Therapy (SBRT) of lung by direct measurment in anthropomorphic phantom and by Monte Carlo calculation
    Salter, B
    Rassiah, P
    Tanyi, J
    Cheng, C
    Fuss, M
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1716 - 1716
  • [2] Monte Carlo characterization of target doses in stereotactic body radiation therapy (SBRT)
    Rassiah-Szegedi, Premavathy
    Salter, Bill J.
    Fuller, Clifton D.
    Blough, Melissa
    Papanikolaou, Niko
    Fuss, Martin
    [J]. ACTA ONCOLOGICA, 2006, 45 (07) : 989 - 994
  • [3] Charcterization of mean lung dose in Stereotactic Body Radiation Therapy (SBRT) by direct measurement in anthropomorphic phantom and by Monte Carlo calculation
    Salter, B
    Rassiah, P
    Tanyi, J
    Cheng, C
    Fuss, M
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1720 - 1720
  • [4] Monte Carlo evaluation of target dose coverage in lung stereotactic body radiation therapy with flattening filter-free beams
    Vassiliev, Oleg N.
    Peterson, Christine B.
    Chang, Joe Y.
    Mohan, Radhe
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 81 - 87
  • [5] Impact of Lack of Coverage Established By Monte Carlo Dose Calculation on Small Island Lung Tumors Treated With Stereotactic Body Radiation Therapy (SBRT)
    Tanguy, R.
    Sunyach, M. P.
    Carrie, C.
    Zahra-Ayadi, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E438 - E438
  • [6] Measurement of Dose Blurring Effect Due to Respiratory Motion for Lung Stereotactic Body Radiation Therapy (SBRT) Using Monte Carlo Based Calculation Algorithm
    Badkul, R.
    Pokhrel, D.
    Ramanjappa, T.
    Jiang, H.
    Lominska, C.
    Wang, F.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3592 - 3592
  • [7] Target Dose Characterization by Monte Carlo versus Pencil Beam Algorithm for Lung Stereotactic Body Radiation Therapy (SBRT): A Preliminary Analysis in 20 Successfully Treated Patients
    Chen, A. Y.
    Li, Q.
    McNair, S.
    Xu, K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S852 - S853
  • [8] Characterization of doses in stereotactic body radiation therapy (SBRT) via Monte Carlo calculation
    Salter, B
    Rasiah, P
    Fuss, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S539 - S540
  • [9] Measurements of CyberKnife Stereotactic Body Radiation Therapy (SBRT) Dose to Target Volumes in a Dynamic Lung Phantom and Comparison with Monte Carlo versus Ray-Tracing Dose Calculations
    Xiang, H. F.
    Fisher, K.
    Russo, G. A.
    Keohan, S.
    Perrone, M.
    Ebright, M.
    Willins, J.
    Lu, H.
    Kachnic, L. A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S868 - S868
  • [10] Stereotactic body radiation therapy (SBRT) for lung metastases
    Okunieff, Paul
    Petersen, Anncatrine L.
    Philip, Abraham
    Milano, Michael T.
    Katz, Alan W.
    Boros, Laszlo
    Schell, Michael C.
    [J]. ACTA ONCOLOGICA, 2006, 45 (07) : 808 - 817