Comparison of tip apex distance and cut-out complications between helical blades and lag screws in intertrochanteric fractures among the elderly: a meta-analysis

被引:22
|
作者
Li, Shuang [1 ,2 ]
Chang, Shi-Min [1 ]
Niu, Wen-Xin [3 ]
Ma, Hui [2 ]
机构
[1] Tongji Univ, Yangpu Hosp, Sch Med, Dept Orthopaed Surg, Shanghai 200090, Peoples R China
[2] First Rehabil Hosp Shanghai, Dept Orthopaed Surg, Shanghai 200090, Peoples R China
[3] Tongji Univ, Yang Zhi Rehabil Hosp, Sch Med, Shanghai 201619, Peoples R China
关键词
FEMORAL NAIL ANTIROTATION; DYNAMIC HIP SCREW; UNSTABLE TROCHANTERIC FRACTURES; GAMMA-NAIL; 3RD-GENERATION; FIXATION; DEVICES; 2ND;
D O I
10.1007/s00776-015-0770-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To investigate whether helical blade implant systems have advantages in terms of tip apex distance (TAD) and cut-out rate in comparison to conventional lag screws for intertrochanteric fractures in a geriatric population. Relevant articles were sourced from the MEDLINE, Embase, Ovid and Cochrane Library databases from inception through March 2015. All randomized controlled trials (RCTs) comparing outcomes between helical blade and lag screw implant systems were selected. Mean TAD values and reported cut-out complications were noted. Each author independently assessed the relevance of the enrolled studies and the quality of the extracted data. Data were analyzed using R software. Ten studies including 1831 patients were eligible for this review, seven of which were included in a combined analysis of dichotomous outcomes and five in a combined analysis of continuous outcomes. The results revealed that, compared with lag screw implantations, the use of helical blades led to a lower rate of cut-out complications (95 % CI: 0.28-0.96, P = 0.036). Patients who experienced cut-out complications had a significantly greater tip apex distance (95 % CI: 0.68-1.34, P < 0.001). However, the actual tip apex distances were similar between the screw group and blade group (95 % CI: -0.44-0.79, P = 0.58). No difference in TAD values was found between blades and screws. In addition, the cut-out risk in the blade-design group was lower than that of the screw group. Therefore, TAD is not an accurate predictor of cut-out risk.
引用
收藏
页码:1062 / 1069
页数:8
相关论文
共 14 条
  • [1] Proposal of a modified tip apex distance for prediction of lag screw cut-out in trochanteric hip fractures
    Selim, Amr
    Al-Hadithy, Nawfal
    Diab, Nader M.
    Ahmed, Abdulla Mohamed
    Kader, Khaled Fawzy Abdel
    Hegazy, Mohamed
    Azeem, Hazem Abdel
    Barakat, Ahmed Samir
    SICOT-J, 2023, 9
  • [2] Tip-apex distance as a risk factor for cut-out in cephalic double-screw nailing of intertrochanteric femur fractures
    Coviello, M.
    Abate, A.
    Maccagnano, G.
    Ippolito, F.
    Nappi, V.
    Abbaticchio, A. M.
    Caiaffa, E.
    Caiaffa, V.
    BONE & JOINT OPEN, 2024, 5 (06): : 457 - 463
  • [3] Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures
    Jeffrey A. Geller
    Comron Saifi
    Todd A. Morrison
    William Macaulay
    International Orthopaedics, 2010, 34 : 719 - 722
  • [4] Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures
    Geller, Jeffrey A.
    Saifi, Comron
    Morrison, Todd A.
    Macaulay, William
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (05) : 719 - 722
  • [5] Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures
    Andruszkow, Hagen
    Frink, Michael
    Froemke, Cornelia
    Matityahu, Amir
    Zeckey, Christian
    Mommsen, Philipp
    Suntardjo, Stefanie
    Krettek, Christian
    Hildebrand, Frank
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (11) : 2347 - 2354
  • [6] Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures
    Hagen Andruszkow
    Michael Frink
    Cornelia Frömke
    Amir Matityahu
    Christian Zeckey
    Philipp Mommsen
    Stefanie Suntardjo
    Christian Krettek
    Frank Hildebrand
    International Orthopaedics, 2012, 36 : 2347 - 2354
  • [7] No difference between lag screw and helical blade for cephalomedullary nail cut-out a systematic review and meta-analysis
    Ng, Mitchell
    Shah, Nihar S.
    Golub, Ivan
    Ciminero, Matthew
    Zhai, Kevin
    Kang, Kevin K.
    Emara, Ahmed K.
    Piuzzi, Nicolas S.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (08): : 1617 - 1625
  • [8] No difference between lag screw and helical blade for cephalomedullary nail cut-out a systematic review and meta-analysis
    Mitchell Ng
    Nihar S. Shah
    Ivan Golub
    Matthew Ciminero
    Kevin Zhai
    Kevin K. Kang
    Ahmed K. Emara
    Nicolas S. Piuzzi
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 1617 - 1625
  • [9] Predicting cut-out in intertrochanteric fractures fixed with cephalomedullary nails: the role of tip-to-apex distance referenced to calcar (calTAD)--A retrospective analysis of 158 cases
    Garabano, German
    Juri, Andres
    Alamino, Leonel Perez
    Rodriguez, Joaquin Anibal
    Pesciallo, Cesar Angel
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 35 (01):
  • [10] Predictive value of tip-apex distance and calcar-referenced tip-apex distance for cut-out in 398 femoral intertrochanteric fractures treated in a private practice with dynamic intramedullary nailing
    Barra, Amariel E.
    Barrios, Carlos
    FRONTIERS IN SURGERY, 2024, 11