Measurement of the thickness of the lens with the use of all fiber low-coherence interferometer

被引:0
|
作者
Jozwik, Michalina [1 ]
Stepien, Karol [2 ]
Lipinski, Stanislaw [2 ]
Budnicki, Dawid [2 ]
Napierala, Marek [2 ]
Nasilowski, Tomasz [2 ]
机构
[1] Polish Ctr Photon & Fibre Opt, PL-36060 Glogow Malopolski, Poland
[2] InPhoTech Ltd, PL-00195 Warsaw, Poland
关键词
Lens thickness measurement; low-coherence interferometry; Mach-Zehnder fiber interferometer; REFRACTIVE-INDEX;
D O I
10.1117/12.2225066
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper we present experimental results of measurements of the lens thickness carried out using all fiber low-coherence interferometer. A new interferometric device for measuring the thickness of the lens using optical fibers has been developed in response to market demand. It ensures fast, non-contact and accurate measurement. This work focuses above all on the conducting tests to determine the repeatability of the measurement and to verify the ability of using this method in industrial conditions. The system uses a Mach-Zehnder interferometer in which one of the arms is the reference part and the second arm containing the test element is the measurement part. The measurement rate and the easiness of placement of the test lens in the system give the possibility to automate the measurement process. We present the measurement results, which show that the use of low-coherence interferometry allows achieving high measurement accuracy and meeting other industrial needs.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Low-Coherence Fiber Differential Interferometer With Adjustable Measurement Range
    Zhen, Shenglai
    Chen, Jian
    Li, Hui
    Wang, Xiaoguang
    Zhang, Bo
    Yu, Benli
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2015, 27 (08) : 895 - 898
  • [2] Low-coherence interferometer system for the simultaneous measurement of refractive index and thickness
    Maruyama, H
    Inoue, S
    Mitsuyama, T
    Ohmi, M
    Haruna, M
    [J]. APPLIED OPTICS, 2002, 41 (07) : 1315 - 1322
  • [3] Simultaneous thickness and group index measurement with a single arm low-coherence interferometer
    Zilio, S. C.
    [J]. OPTICS EXPRESS, 2014, 22 (22): : 27392 - 27397
  • [4] Low-coherence interferometer for contact lens surface metrology
    Heideman, Kyle C.
    Greivenkamp, John E.
    [J]. OPTICAL ENGINEERING, 2016, 55 (03)
  • [5] MEASUREMENT OF CORNEAL THICKNESS BY LOW-COHERENCE INTERFEROMETRY
    HITZENBERGER, CK
    [J]. APPLIED OPTICS, 1992, 31 (31): : 6637 - 6642
  • [6] Measurement of Lens-Center Thickness Based on Low-Coherence Interference with Transmitted Illumination
    Liu Jingyou
    Lei Feng
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2019, 56 (12)
  • [7] The use of low-coherence interferometer for sugar content determination
    Jedrzejewska-Szczerska, M.
    [J]. SARATOV FALL MEETING 2014: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XVI; LASER PHYSICS AND PHOTONICS XVI; AND COMPUTATIONAL BIOPHYSICS, 2015, 9448
  • [8] Axial-scanning low-coherence interferometer method for noncontact thickness measurement of biological samples
    Kim, Do-Hyun
    Song, Chul-Gyu
    Ilev, Ilko K.
    Kang, Jin U.
    [J]. APPLIED OPTICS, 2011, 50 (06) : 970 - 974
  • [9] Measurement of transmitted wavefront error and homogeneity with a low-coherence interferometer
    Freischlad, Klaus
    [J]. OPTIFAB 2021, 2021, 11889
  • [10] Low-coherence tandem interferometer for measurement of group refractive index without knowledge of the thickness of the test sample
    Hirai, A
    Matsumoto, H
    [J]. OPTICS LETTERS, 2003, 28 (21) : 2112 - 2114