Preconcentration and determination of mercury in high purity arsenic

被引:10
|
作者
Swain, K [1 ]
Raje, N [1 ]
Kayasth, S [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Analyt Chem, Mumbai 400085, India
关键词
ion exchange; mercury; arsenic; neutron activation analysis;
D O I
10.1016/S0003-2670(99)00732-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical procedure for the determination of trace amounts of mercury in high purity arsenic metal/oxide, widely used in electronic devices, is presented in this manuscript. Pre-concentration of mercury from a large amount of the matrix on a small amount of anion exchanger in hydrochloric acid medium was used to enrich the analyte concentration, followed by its determination using neutron activation analysis (NAA). A detailed study was carried out for the quantitative separation of the analyte from the matrix along with the precautions to be considered for the accurate determination of this volatile element. The separation of the analyte was quantitative and the validity of the procedure was confirmed by tracer studies, standard addition of the analyte to the matrix and by analyzing high purity arsenic for which certified values are available. The overall reproducibility of the separation procedure was 2-10%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:297 / 301
页数:5
相关论文
共 50 条
  • [1] THE DETERMINATION OF TRACE IMPURITIES OF COPPER AND LEAD IN HIGH-PURITY ARSENIC BY AMALGAM POLAROGRAPHY ON A STATIONARY MERCURY DROP
    KATAEV, GA
    ZAKHAROVA, EA
    INDUSTRIAL LABORATORY, 1963, 29 (05): : 542 - 545
  • [2] GFAAS determination of trace amounts of arsenic in high purity nickel
    Jing, Kui
    Guo, Xing-Jia
    Liu, Xin
    Tang, Xia
    Lihua Jianyan: Huaxue Fence/Physical Testing and Chemical Analysis Part B:Chemical Analysis, 2002, 38 (12):
  • [3] PHOTOMETRIC-DETERMINATION OF ARSENIC IN HIGH-PURITY CHEMICALS
    ACKERMANN, G
    KOTHE, J
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 323 (02): : 135 - 138
  • [4] DETERMINATION OF IRON IN HIGH-PURITY MERCURY BY STRIPPING VOLTAMMETRY
    ANISIMOVA, LS
    KATYUKHIN, VE
    SLIPCHENKO, VF
    KAPLIN, AA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1979, 34 (09): : 1431 - 1433
  • [5] Direct Determination of Trace Element Arsenic in High Purity Nickel by GFAAS
    Guo, Xing-Jia
    Jing, Kui
    Jing, Run
    Yang, Qi
    Liu, Xin
    Tang, Xia
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2002, 22 (06):
  • [6] FLUORIMETRIC DETERMINATION OF MICROQUANTITIES OF SELENIUM IN HIGH-PURITY ARSENIC CHLORIDE
    LUFT, BD
    KHUSID, LB
    NAZARENK.II
    SHEMET, VV
    INDUSTRIAL LABORATORY, 1971, 37 (09): : 1327 - &
  • [7] DETERMINATION OF ZINC IN HIGH-PURITY ARSENIC CHLORIDE BY INVERSION CHRONOVOLTAMMETRY
    CISZEWSKI, A
    CHEMIA ANALITYCZNA, 1978, 23 (06): : 1045 - 1047
  • [8] PHOTOMETRIC-DETERMINATION OF ARSENIC AND PHOSPHORUS IN HIGH-PURITY CHEMICALS
    ACKERMANN, G
    KOTHE, J
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 323 (03): : 271 - 275
  • [9] Direct determination of trace, element arsenic in high purity nickel by GFAAS
    Guo, XJ
    Jing, K
    Jing, R
    Yang, Q
    Liu, X
    Tang, X
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2002, 22 (06) : 1040 - 1042
  • [10] DETERMINATION OF TIN IN HIGH-PURITY ARSENIC TRICHLORIDE BY INVERSE VOLTAMMETRY
    CISZEWSKI, A
    CHEMIA ANALITYCZNA, 1977, 22 (03): : 571 - 573