Health Effects Study and Safe Distance Determination Near an Electrical Distribution Network

被引:2
|
作者
Nafar, Mehdi [1 ]
机构
[1] Islamic Azad Univ, Dept Elect Engn, Marvdasht Branch, Marvdasht, Iran
来源
关键词
Electric Field; Electrical Distribution Systems; Magnetic Field; MATLAB; Safe Margin; Software Package; MAGNETIC-FIELDS; NEURODEGENERATIVE DISEASES; TRANSMISSION-LINES; VICINITY;
D O I
10.26866/jees.2019.19.3.172
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Living organisms are affected by environmental pollution, one main source of which is the electric and magnetic fields (EMFs) of electrical distribution lines that produce high-voltage currents. Nowadays, electrical power transmission lines and distribution systems are becoming increasingly prevalent, with power distribution lines passing through cities and being located very close to buildings. For this reason, there has been significant public concern, which has escalated because of reports about the adverse health effects of the EMFs of power distribution systems. In this paper, the environmental pollution produced by several different configurations of electrical distribution systems in Iran is studied. The paper presents new software to calculate EMFs around electric power lines. Using this software and based on maximum allowable EMFs, a safe margin around selected power lines has been determined. According to the study results, it seems that in Iran this safe distance is not met. Therefore, the standards relating to power distribution lines should be reviewed.
引用
下载
收藏
页码:172 / 176
页数:5
相关论文
共 50 条
  • [1] Calculation of electrical distance in the distribution network
    Rusnak, Jozef
    Rusek, Stanislav
    Gono, Radomir
    PROCEEDINGS OF THE 5TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRIC POWER ENGINEERING - ELEKTROENERGETIKA 2009, 2009, : 228 - +
  • [2] Study on the distribution of near-fault strong ground motion and the safe distance of structure near fault
    Liu, QF
    Ding, HP
    Jin, X
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 629 - 635
  • [3] Basic Study on Safe Separation Distance of Electronic Circuits near AC Transmission Lines
    Miyajima K.
    Arima T.
    Uno T.
    IEEJ Transactions on Fundamentals and Materials, 2020, 140 (11): : 516 - 521
  • [4] Determination of Safe Depth and Lateral Distance of Unsupported Excavation Near Mat Foundation in Cohesive Soils Using PLAXIS
    Khalid, Muhammad Hamza
    Alshameri, Badee
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2022, 25 (02): : 249 - +
  • [5] The effects of a driver assistance system for safe speed and safe distance - A real-life field study
    Adell, Emeli
    Varhelyi, Andras
    dalla Fontana, Mario
    TRANSPORTATION RESEARCH PART C-EMERGING TECHNOLOGIES, 2011, 19 (01) : 145 - 155
  • [6] Investigation of line displacement in terms of electrical field distribution and safe right of way distance in energy transmission systems
    Kumru, Celal Fadil
    Arikan, Oktay
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2020, 26 (02): : 279 - 285
  • [7] Hydrogen safety effect calculation (dispersion and thermal radiation effects) for determination of siting and safe distance
    Venkatesan, Rubachandran
    Harun, Razif
    Yusoff, Hamdan Mohamed
    Razak, Musab Abdul
    PROCESS SAFETY PROGRESS, 2024, 43 (S1) : S161 - S169
  • [8] Study on health effects of disassembling imported electrical equipment
    Shen, DS
    He, YH
    Fang, CR
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2004, 72 (06) : 1157 - 1163
  • [9] Study on Health Effects of Disassembling Imported Electrical Equipment
    D. S. Shen
    Y. H. He
    C. R. Fang
    Bulletin of Environmental Contamination and Toxicology, 2004, 72 : 1157 - 1163
  • [10] A Case Study on Optimizing an Electrical Distribution Network Using a Genetic Algorithm
    Fletcher, James
    Fernando, Tyrone
    Iu, Herbert
    Reynolds, Mark
    Fani, Shervin
    2015 IEEE 24TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2015, : 20 - 25