Determination of four antiepileptic drugs with solvent assisted dispersive solid phase microextraction - Gas chromatography-mass spectrometry in human urine samples

被引:18
|
作者
Mohammadi, Parisa [1 ]
Masrournia, Mahboubeh [1 ]
Es'haghi, Zarrin [2 ]
Pordel, Mehdi [1 ]
机构
[1] Islamic Azad Univ, Dept Chem, Mashhad Branch, Mashhad, Razavi Khorasan, Iran
[2] Payam Noor Univ, Dept Chem, Tehran, Iran
关键词
Antiepileptic drugs; Urine samples; Dispersive solid phase microextraction; GC-MS; LIQUID-LIQUID MICROEXTRACTION; VALPROIC ACID; NANOMATERIALS; EXTRACTION; PREGABALIN; SORBENTS; PRECONCENTRATION; WATER;
D O I
10.1016/j.microc.2020.105542
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper solvent assisted dispersive solid-phase microextraction (SA-DSPME) as a rapid and comprehensive sample preparation method was developed to extract and cleanup four antiepileptic drugs (AEDs); valproic acid, phenobarbital, levetiracetam, and pregabalin from human urine samples. In the procedure, the dispersion of the sorbent was attained by rapid injection of a mixture of the adsorbent and disperser solvent into the aqueous sample to increase the contact surface and reduce the extraction time and amount of sorbent consumption. Several sorbents such as magnetic Fe3O4, Fe3O4@graphene, Fe3O4@graphene oxide, Fe3O4@MWCNTs, Fe3O4@SiO2, Fe3O4@SiO2@TiO2, Fe3O4@Chitosan, and NiO NPs were tested to extract the target drugs and the results compared. Among them, Fe3O4@SiO2 was chosen as the best sorbent, and its structure characterized using FESEM, FTIR, and EDX. Besides, effective factors in the SA-DSPME, including the type of disperser solvent and desorption solvent, extraction time, desorption time, pH, and disperser solvent and desorption solvent volume, were optimized using one factor at a time and design experiment strategy. Under the optimum conditions, the calibration curves were linear in the range of 0.2-100 ng mL(-1) for valproic acid and phenobarbital, and 0.4-120 ng mL(-1) for levetiracetam and pregabalin. Limit of detections and limit of quantifications were lower than 0.11 and 0.4 ng mL(-1) for the analytes. Besides, the procedure showed suitable relative standard deviations (<= 3.8%) and preconcentration factors (>= 133.9) for the determination of the antiepilepsy drugs. Analysis of human urine samples confirmed that the SA-DSPME-GC procedure is an appropriate method for measuring the target drugs in biological samples with recoveries between 92.9 and 103.2 % and RSD less than 4.7%.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Dispersive solid-phase extraction for simultaneous determination of four amphetamines drugs in urine using gas chromatography-mass spectrometry
    Elboraie, Mahir Z.
    Elbashir, Abdalla A.
    Eid, Eltayeb E. M.
    Aboul-Enein, Hassan Y.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2022, 19 (03) : 753 - 762
  • [2] Fast determination of paraquat in plasma and urine samples by solid-phase microextraction and gas chromatography-mass spectrometry
    Gao, Lina
    Liu, Junting
    Wang, Chunyuan
    Liu, Guojie
    Niu, Xiaodong
    Shu, Cuixia
    Zhu, Juan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 944 : 136 - 140
  • [3] Determination of dichloromethane, trichloroethylene and perchloroethylene in urine samples by headspace solid phase microextraction gas chromatography-mass spectrometry
    Poli, D
    Manini, P
    Andreoli, R
    Franchini, I
    Mutti, A
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (01): : 95 - 102
  • [4] Solid-phase microextraction of human plasma samples for determination of sufentanil by gas chromatography-mass spectrometry
    Paradis, C
    Dufresne, C
    Bolon, M
    Boulieu, R
    THERAPEUTIC DRUG MONITORING, 2002, 24 (06) : 768 - 774
  • [5] DETERMINATION OF VOLATILES IN MOUSE URINE BY HEADSPACE SOLID PHASE MICROEXTRACTION AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    Arnaiz, Esther
    Moreno, Daniel
    Quesada, Roberto
    ANALYTICAL LETTERS, 2014, 47 (05) : 721 - 729
  • [6] Determination of cocaine and cocaethylene in urine by solid-phase microextraction and gas chromatography-mass spectrometry
    Yonamine, Mauricio
    Saviano, Alessandro Morais
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (10) : 1071 - 1075
  • [7] Determination of isophorone in food samples by solid-phase microextraction coupled with gas chromatography-mass spectrometry
    Kataoka, Hiroyuki
    Terada, Yohei
    Inoue, Reiko
    Mitani, Kurie
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1155 (01) : 100 - 104
  • [8] Determination of anti-inflammatory drugs in water samples, by in situ derivatization, solid phase microextraction and gas chromatography-mass spectrometry
    Araujo, Lilia
    Wild, Johana
    Villa, Noreiva
    Camargo, Nuris
    Cubillan, Dalia
    Prieto, Avismelsi
    TALANTA, 2008, 75 (01) : 111 - 115
  • [9] Determination of fipronil by solid-phase microextraction and gas chromatography-mass spectrometry
    Vílchez, JL
    Prieto, A
    Araujo, L
    Navalón, A
    JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) : 215 - 221
  • [10] Determination of fentanyl in human breath by solid-phase microextraction and gas chromatography-mass spectrometry
    Wang, Changsong
    Li, Enyou
    Xu, Guowang
    Wang, Hui
    Gong, Yulei
    Li, Peng
    Liu, Shujuan
    He, Ying
    MICROCHEMICAL JOURNAL, 2009, 91 (02) : 149 - 152