Feasibility of virtual nonenhanced images derived from single-source fast kVp-switching dual-energy CT in evaluating gastric tumors

被引:23
|
作者
Chai, Yaru [1 ]
Xing, Jingjing [1 ]
Gao, Jianbo [1 ]
Lv, Peijie [1 ]
Liang, Pan [1 ]
Liu, Jie [1 ]
Guo, Ying [2 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Radiol, Zhengzhou 450052, Henan, Peoples R China
[2] GE Hlth Care, CT Res Ctr, Beijing 100176, Peoples R China
基金
中国国家自然科学基金;
关键词
Tomography; X-ray computed; Virtual nonenhanced; Gastric tumor; Image quality; Radiation dose; COMPUTED-TOMOGRAPHY; RECONSTRUCTION; QUALITY;
D O I
10.1016/j.ejrad.2015.11.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of virtual nonenhanced (VNE) images derived from single-source fast kVp-switching dual-energy CT, namely material suppressed iodine (MSI) images in evaluating gastric tumors, and to calculate potential radiation dose reductions for a dual-phase gemstone spectral imaging (GSI) abdominal CT compared with a standard triple-phase protocol. Materials and methods: The institutional review board approved this prospective study; all patients provided written informed consent. 95 patients underwent preoperative enhanced CT that included true nonenhanced (TNE) with conventional 120 kVp mode, arterial phase (AP) and venous phase (VP) with GSI mode. MSI images were obtained from enhanced images of AP. Two abdominal radiologists independently evaluated the image quality of TNE and MSI images using a 5-point scale. Interobserver agreement was accessed by kappa value. The sensitivity for lesions on TNE and MSI images were evaluated. The CT number of various regions and image noise was measured on TNE and MSI images. The relative enhancement CT value of lesions, contrast to noise( CNR) of gastric tumors and effective radiation doses for triplephase and dual-phase protocol were calculated. Differences were tested for statistical significance using Wilcoxon signed rank test and paired t-test. Results: Interobserver agreement about image quality was excellent( all kappa >0.750). No significant difference in image quality was found between TNE 4.32 I 0.53 and MSI 4.21 I 0.51 images (P > 0.05). In respect to the sensitivities for gastric tumors, lymph node and liver metastasis, there were no significant differences between TNE and MSI images (all P > 0.05). The CT number on TNE and MSI images, respectively, for gastric tumor were 32.79HU I 6.45 and 35.02HU I 5.01 (P= 0.006); lymph nodes, 31.33HU I 6.37 and 31.61HU I 5.73 (P= 0.334); liver metastasis, 37.79HU I 8.40 and 39.76HU I 8.50 (P = 0.041); liver, 56.56HU I 7.87 and 58.32HU I 8.73 (P = 0.057); psoas muscle, 52.30HU I 5.63 and 51.80HU I 6.86 (P = 0.533); aorta, 38.16HU I 4.91 and 42.49HU I 4.49 (P < 0.001). The CT relative enhancement value of gastric tumors, lymph node and liver metastasis had no significant difference between TNE and MSI images (P=0.083, 0.194, 0.156). MSI images had higher image noise than TNE images (P< 0.001). The CNR of gastric tumor on MSI images was higher than that on TNE images (P< 0.001). The effective dose for triple-phase was 25.1 mSv I 6.2 and that for dual-phase was 17.7 mSv I 4.1. The dose saving by removing the TNE was 7.5 mSv (30.5%). Conclusion: In patients with gastric tumors, the MSI images derived from single-source fast kVp-switching dual-energy CT can provide comparable image quality to TNE images and reliable diagnostic information; replacing TNE images will lower radiation dose by 30.5%. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:366 / 372
页数:7
相关论文
共 50 条
  • [1] Feasibility of coronary artery calcium scoring on virtual unenhanced images derived from single-source fast kVp-switching dual-energy coronary CT angiography
    Yamada, Yoshitake
    Jinzaki, Masahiro
    Okamura, Teppei
    Yamada, Minoru
    Tanami, Yutaka
    Abe, Takayuki
    Kuribayashi, Sachio
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (05) : 391 - 400
  • [2] Improved imaging of colorectal liver metastases using single-source, fast kVp-switching, dual-energy CT: preliminary results
    Ratajczak, Przemyslaw
    Serafin, Zbigniew
    Slawinska, Agata
    Slupski, Maciej
    Leszczynski, Waldemar
    POLISH JOURNAL OF RADIOLOGY, 2018, 83 : E514 - E520
  • [3] Assessment of Solitary Pulmonary Nodules Based on Virtual Monochrome Images and Iodine-Dependent Images Using a Single-Source Dual-Energy CT with Fast kVp Switching
    Zegadlo, Arkadiusz
    Zabicka, Magdalena
    Kania-Pudlo, Marta
    Maliborski, Artur
    Rozyk, Aleksandra
    Sosnicki, Witold
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 17
  • [4] Virtual monoenergetic imaging in rapid kVp-switching dual-energy CT (DECT) of the abdomen: impact on CT texture analysis
    Baliyan, Vinit
    Kordbacheh, Hamed
    Parameswaran, Bimal
    Ganeshan, Balaji
    Sahani, Dushyant
    Kambadakone, Avinash
    ABDOMINAL RADIOLOGY, 2018, 43 (10) : 2693 - 2701
  • [5] The Value of Nonenhanced Single-Source Dual-Energy CT for Differentiating Metastases From Adenoma in Adrenal Glands
    Ju, Ye
    Liu, Ailian
    Dong, Yue
    Liu, Yijun
    Wang, Heqing
    Sun, Meiyu
    Pu, Renwang
    Chen, Anliang
    ACADEMIC RADIOLOGY, 2015, 22 (07) : 834 - 839
  • [6] Virtual monoenergetic imaging in rapid kVp-switching dual-energy CT (DECT) of the abdomen: impact on CT texture analysis
    Vinit Baliyan
    Hamed Kordbacheh
    Bimal Parameswaran
    Balaji Ganeshan
    Dushyant Sahani
    Avinash Kambadakone
    Abdominal Radiology, 2018, 43 : 2693 - 2701
  • [7] Initial Evaluation of Virtual Un-Enhanced Imaging derived from Fast kVp-Switching Dual Energy Contrast Enhanced CT for the Abdomen
    Joshi, M.
    Mendonca, P.
    Okerlund, D.
    Lamb, P.
    Kulkarni, N.
    Pinho, D.
    Sahani, D.
    Bhotika, R.
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [8] Multiparametric Evaluation of Head and Neck Squamous Cell Carcinoma Using a Single-Source Dual-Energy CT with Fast kVp Switching: State of the Art
    Lam, Stephanie
    Gupta, Rajiv
    Kelly, Hillary
    Curtin, Hugh D.
    Forghani, Reza
    CANCERS, 2015, 7 (04) : 2201 - 2216
  • [9] Effects of Gantry Rotation Time On CT Number Accuracy in Single-Source Dual Energy CT Imaging with Fast-KVp Switching
    Liu, X.
    Cody, D.
    Rong, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 154 - +
  • [10] Validation of Virtual Monochromatic Images and Effect of Body Size Obtained Using a Rapid kVp-switching Dual-energy Computed Tomography System: A Phantom Study
    Wu, Tung-Hsin
    Ting, Yun-Lung
    Hwang, Yi-Shuan
    Chui, Chen-Shou
    Lin, Cristopher K. J.
    HEALTH PHYSICS, 2022, 123 (04): : 287 - 294