Tests on JET TF coil insulation

被引:4
|
作者
Last, JR [1 ]
Jeskins, JS [1 ]
Kaye, AS [1 ]
Riccardo, V [1 ]
机构
[1] UKAEA Euratom Fus Assoc, Abingdon OX14 3DB, Oxon, England
关键词
epoxy glass insulation; magnetic field coils;
D O I
10.1109/TASC.2002.1018625
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The epoxy glass insulation from a JET toroidal field (TF) coil was extensively tested as part of a study to permit operation of JET at a field 20% higher than the design value [1]. The measurements were performed on specimens taken from a coil that had been in use for several years. The JET TF coils are D-shaped and made of two pancakes of 12 copper turns, with 2 mm inter-turn insulation and 6 mm interpancake insulation, all wrapped by 7 mm of ground insulation (the total coil cross-section area being about 0.1 m(2)). Most of the tests were carried out on specimens taken from the straight leg of the used coil. Tests on inter-turn insulation included shear strength and shear modulus, fracture tests, micrographic analysis, void and glass-resin content and second order glass transition temperature. Tests on ground insulation included tensile strength and elastic moduli, shear strength and shear modulus, inter-laminar shear strength and elastic modulus, mode 1 and mode 2 fracture tests. The results were not as consistent as might be achieved using laboratory specimens, but we consider that they are more representative of the quality achievable in actual manufacture.
引用
收藏
页码:1238 / 1241
页数:4
相关论文
共 50 条
  • [1] Analysis and tests of TF magnet insulation samples for the JET upgrade to 4 tesla
    Miele, P
    Bertolini, E
    Bettinali, L
    Kaye, A
    Last, J
    Papastergiou, S
    Riccardo, V
    Visca, E
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 1333 - 1336
  • [2] Qualification of the resin for the ITER TF coil insulation
    Prokopec, R.
    Humer, K.
    Maix, R. K.
    Fillunger, H.
    Weber, H. W.
    Knaster, J.
    Savary, F.
    FUSION ENGINEERING AND DESIGN, 2011, 86 (6-8) : 1436 - 1439
  • [3] JET TF COIL FAULTS - DETECTION, DIAGNOSIS AND PREVENTION
    LAST, JR
    BERTOLINI, E
    BONICELLI, T
    DOLGETTA, N
    PRESLE, P
    ZULLO, G
    IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (04) : 2154 - 2157
  • [4] JET TF coil fault. Detection, diagnosis and prevention
    Last, J.R.
    Bonicelli, T.
    Cooke, M.
    Dolgetta, N.
    Huguet, M.
    Lanza, R.
    Noll, P.
    Presle, P.
    Sborchia, C.
    Proceedings of the Symposium on Fusion Technology, 1991,
  • [5] Characterization of Bonded Glass/Polyimide Tapes for the ITER TF Coil Insulation
    Prokopec, Rainer
    Humer, Karl
    Maix, Reinhard K.
    Fillunger, Harald
    Weber, Harald W.
    Knaster, Juan
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (03)
  • [6] Analysis and Verification of CRAFT TF Coil Turn Insulation Wrapping System
    He, Jian
    Wu, Jiefeng
    Wen, Wei
    Yan, Zhaohui
    Wu, Yu
    Wen, Jun
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (07)
  • [7] Kapton film effect on the mechanical strength of ITER TF coil candidate insulation
    Wang, ZD
    Weber, HW
    MECHANICS OF MATERIALS, 2005, 37 (01) : 113 - 120
  • [8] Influence of reactor irradiation on the mechanical behavior of ITER TF coil candidate insulation systems
    Bittner-Rohrhofer, K
    Humer, K
    Fillunger, H
    Maix, RK
    Wang, ZD
    Weber, HW
    FUSION ENGINEERING AND DESIGN, 2003, 66-68 : 1201 - 1207
  • [9] Mechanical behavior of the ITER TF model coil ground insulation system after reactor irradiation
    Bittner-Rohrhofer, K
    Humer, K
    Fillunger, H
    Maix, RK
    Weber, HW
    CRYOGENICS, 2002, 42 (11) : 697 - 704
  • [10] QUALIFICATION OF A CYANATE ESTER EPOXY BLEND SUPPLIED BY JAPANESE INDUSTRY FOR THE ITER TF COIL INSULATION
    Prokopec, R.
    Humer, K.
    Fillunger, H.
    Maix, R. K.
    Weber, H. W.
    Knaster, J.
    Savary, F.
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 58, 2012, 1435 : 107 - 114