A smartphone-based ratiometric resonance light scattering device for field analysis of Pb2+ in river water samples and immunoassay of alpha fetoprotein using PbS nanoparticles as signal tag

被引:16
|
作者
Wang, Honghai [1 ]
Sun, Yan [1 ]
Li, Huijuan [2 ]
Yue, Weiwei [1 ]
Kang, Qi [1 ]
Shen, Dazhong [1 ]
机构
[1] Shandong Normal Univ, Collaborat Innovat Ctr Functionalized Probes Chem, Key Lab Mol & Nano Probes, Coll Chem Chem Engn & Mat Sci,Minist Educ,Shandon, Jinan 250014, Shandong, Peoples R China
[2] Shandong Univ Sci & Technol, Coll Chem & Environm Engn, Qingdao 266590, Peoples R China
基金
中国国家自然科学基金;
关键词
Smartphone-based; Ratiometric; Resonance light scattering; Field analysis; Immunoassay; HIGHLY SELECTIVE DETECTION; QUANTUM DOTS; IN-SITU; SILVER NANOPARTICLES; PHOTOELECTROCHEMICAL IMMUNOSENSOR; PIEZOELECTRIC IMMUNOSENSOR; COLORIMETRIC IMMUNOASSAY; CARCINOEMBRYONIC ANTIGEN; ULTRASENSITIVE DETECTION; MICROFLUIDIC DEVICE;
D O I
10.1016/j.snb.2018.05.103
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, we developed a smartphone-based ratiometric resonance light scattering (RLS) device for portable field analysis and immunoassay. The RLS signal was detected by the camera in a smartphone controlled by a user-edited APP software. Except the smartphone, the total cost of the detection system itself is about 60 $, including a laser pointer and battery, a twin cuvette, a collective lens, and outside box. By using the RLS brightness ratio between the sample and reference channels in the twin cuvette as the signal indicator, the baseline drifts due to the variations in incident light intensity, ambient temperature, and shooting parameters of camera, can be eliminated efficiently. A new brightness indictor, (R - R-0)/(R-max - R), was proposed to linearize the calibration curve. Where R and R-0 are the rightness ratio in sample and blank, R-max is the maximum averaged brightness ratio, respectively. The applicability of the portable RLS device was demonstrated by the field analysis for Pb2+ in environmental water samples, using [CTA](2)PbI4 ] (CAT = cetyltrimethyl ammonium) as the luminophore. The limit of detection for Pb2+ is 0.7 mu gL(-1). By using PbS nanoparticles conjugated second antibody as the signal tag, the RLS method was applied in immunoassay to determine alpha fetoprotein with the limit of detection of 0.1 pg mL(-1). This smartphone-based ratiometric RLS device offers the advantages of good portability, low cost, high sensitivity and reliability.
引用
收藏
页码:358 / 366
页数:9
相关论文
共 3 条
  • [1] A smartphone-based ratiometric fluorescent device for field analysis of soluble copper in river water using carbon quantum dots as luminophore
    Sun, Yuan
    Wei, Min
    Liu, Rui
    Wang, Honghai
    Li, Huijuan
    Kang, Qi
    Shen, Dazhong
    TALANTA, 2019, 194 : 452 - 460
  • [2] Field analysis of Cr(vi) in water samples by using a smartphone-based ultralong absorption path reflection colorimetric device
    Chen, Xiaolan
    Ma, Cheng
    Kang, Qi
    Chen, Yuqin
    Shen, Dazhong
    NEW JOURNAL OF CHEMISTRY, 2021, 45 (05) : 2529 - 2535
  • [3] Smartphone-based three-channel ratiometric fluorescent device and application in filed analysis of Hg2+, Fe3+ and Cu2+ in water samples
    Li, Dejie
    Sun, Yan
    Shen, Qirui
    Zhang, Qiao
    Huang, Wei
    Kang, Qi
    Shen, Dazhong
    MICROCHEMICAL JOURNAL, 2020, 152