Hydrogen sensor based on polymer-filled hollow core fiber with Pt-loaded WO3/SiO2 coating

被引:29
|
作者
Xu, Ben [1 ]
Li, Ping [1 ]
Wang, D. N. [1 ]
Zhao, Chun-Liu [1 ]
Dai, Jixiang [2 ]
Yang, Minghong [2 ]
机构
[1] China Jiliang Univ, Coll Opt & Elect Technol, Hangzhou 310018, Zhejiang, Peoples R China
[2] Wuhan Univ Technol, Natl Engn Lab Fiber Opt Sensing Technol, Wuhan 430070, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical fiber sensor; Pt-loaded WO3/SiO2 coating; Hydrogen sensor; Fabry-Perot interferometer; Temperature; SENSING CHARACTERISTICS; WO3; FILM; INTERFEROMETER;
D O I
10.1016/j.snb.2017.01.206
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, compact and highly sensitive hydrogen sensing device based on a polymer-filled hollow core fiber coated with Pt-loaded WO3/SiO2 is demonstrated. The device is composed of a tiny segment of hollow core fiber (HCF) spliced to a standard single mode fiber (SMF) incorporated with a fiber Bragg grating (FBG). The HCF is filled with polymer and the inner air-gap near the interface between SMF and polymer forms a micro-cavity Fabry-Perot interferometer (FPI). With Pt-loaded WO3/SiO2 coating acting as the catalytic layer, hydrogen undergoes an exothermic reaction with oxygen in air and releases heat when the device is exposed to hydrogen, which induces local temperature change of FPI and hence leads to reflection spectrum shift of the proposed device. Here, the FBG is used to compensate the surrounding temperature effect and eliminate the temperature cross-sensitivity of the device. A wavelength shift of over 35 nm is obtained with a 242-mu m-long polymer-filled HCF for 4% (vol%) H-2 concentration, and the maximum sensitivity of 17.48 nm/% (vol%) H-2 is achieved within the range of 0-4.0% (Vol%) H-2 in air. The sensor device also exhibits fast response time to hydrogen. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:516 / 523
页数:8
相关论文
共 50 条
  • [1] Sagnac interferometer hydrogen sensor based on panda fiber with Pt-loaded WO3/SiO2 coating
    Xu, Ben
    Zhao, C. L.
    Yang, Fan
    Gong, Huaping
    Wang, D. N.
    Dai, JiXiang
    Yang, Minghong
    OPTICS LETTERS, 2016, 41 (07) : 1594 - 1597
  • [2] Hydrogen Sensor Based on NTC Thermistor with Pt-Loaded WO3/SiO2 Coating
    Sun, Changwei
    Xu, Ben
    Li, Ping
    MICROMACHINES, 2022, 13 (12)
  • [3] Polymer-Filled In-Fiber Mach-Zehnder Interferometer with Pt-loaded WO3 Coating for Trace Hydrogen Detection
    Du, Bin
    He, Jun
    Guo, Kuikui
    Xu, Xizhen
    Wang, Ying
    Wang, Yiping
    2020 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP) AND INTERNATIONAL CONFERENCE ON INFORMATION PHOTONICS AND OPTICAL COMMUNICATIONS (IPOC), 2020,
  • [4] Performance of fiber Bragg grating hydrogen sensor coated with Pt-loaded WO3 coating
    Dai, Jixiang
    Yang, Minghong
    Yang, Zhi
    Li, Zhi
    Wang, Yao
    Wang, Gaopeng
    Zhang, Yi
    Zhuang, Zhi
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 657 - 663
  • [5] Sensitive hydrogen sensor based on selectively infiltrated photonic crystal fiber with Pt-loaded WO3 coating
    Wang, Ying
    Wang, D. N.
    Yang, Fan
    Li, Zhi
    Yang, Minghong
    OPTICS LETTERS, 2014, 39 (13) : 3872 - 3875
  • [6] Microstructured FBG hydrogen sensor based on Pt-loaded WO3
    Zhou, Xian
    Dai, Yutang
    Karanja, Joseph Muna
    Liu, Fufei
    Yang, Minghong
    OPTICS EXPRESS, 2017, 25 (08): : 8777 - 8786
  • [7] Highly sensitive hydrogen sensor based on an in-fiber Mach-Zehnder interferometer with polymer infiltration and Pt-loaded WO3 coating
    Du, Bin
    He, Jun
    Yang, Minghong
    Wang, Ying
    Xu, Xizhen
    Wang, Jiachen
    Zhang, Zhe
    Zhang, Fengchan
    Guo, Kuikui
    Wang, Yiping
    OPTICS EXPRESS, 2021, 29 (03) : 4147 - 4158
  • [8] Optical hydrogen sensor based on PDMS-formed double-C type cavities with embedded Pt-loaded WO3/SiO2
    Li, Yina
    Shen, Weimin
    Zhao, Chunliu
    Xu, Ben
    Wang, Dongning
    Yang, Minghong
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 276 : 23 - 30
  • [9] Hydrogen sensors based on Pt-loaded WO3 sensing layers
    Bose, R. Jolly
    Illyaskutty, Navas
    Tan, K. S.
    Rawat, R. S.
    Matham, Murukeshan Vadakke
    Kohler, Heinz
    Pillai, V. P. Mahadevan
    EPL, 2016, 114 (06)
  • [10] Hydrogen performance of fiber Bragg grating hydrogen sensors using Pt-loaded WO3 coating as sensing materials
    Dai, Jixiang
    Yang, Minghong
    Yang, Zhi
    Li, Zhi
    Wang, Yao
    Zhang, Yi
    Zhuang, Zhi
    FOURTH ASIA PACIFIC OPTICAL SENSORS CONFERENCE, 2013, 8924