Fine synchronization of the CMS muon drift tubes local trigger

被引:4
|
作者
Aldaya, M.
Amapane, N.
Battilana, C.
Bellato, M.
Benvenuti, A.
Bonacorsi, D.
Bontenackels, M.
Capiluppi, P.
Castellani, L.
Cavallo, F. R.
Cerminara, G.
Cerrada, M.
Checchia, P.
Conti, E.
de la Cruza, B.
Dal Corso, F.
Dallavalle, G. M.
Fernandez, C.
Fernandez de Troconiz, J.
Fouz, M. C.
Gasparini, F.
Gasparini, U.
Giacomelli, P.
Giunta, M.
Gonella, F.
Guiducci, L.
Hebbeker, T.
Hoepfner, K.
Jimenez, I.
Josa, I.
Lacaprara, S.
Lippi, I.
Marcellini, S.
Maron, G.
Masetti, G.
Meneguzzo, A. T.
Monaco, V.
Montanari, A.
Navarria, F.
Odorici, F.
Parenti, A.
Passaseo, M.
Pegoraro, M.
Perrotta, A.
Puerta, J.
Reithler, H.
Romero, L.
Ronchese, P.
Rossi, A.
Rovelli, T.
机构
[1] Univ Padua, Dipartimento Fis, I-35131 Padua, Italy
[2] Ist Nazl Fis Nucl, I-35131 Padua, Italy
[3] CIEMAT, Div Fis Particulas, E-28040 Madrid, Spain
[4] Univ Turin, Dipartimento Fis, I-10125 Turin, Italy
[5] Ist Nazl Fis Nucl, Turin, Italy
[6] Univ Bologna, Dept Fis, I-40127 Bologna, Italy
[7] Ist Nazl Fis Nucl, I-40127 Bologna, Italy
[8] Rhein Westfal TH Aachen, Inst Phys 3, D-52056 Aachen, Germany
[9] Autonomous Univ Madrid, E-28049 Madrid, Spain
[10] CERN, European Ctr Nucl Res, CH-1211 Geneva, Switzerland
[11] Ist Nazl Fis Nucl, Lab Nazl Legnaro, I-35020 Legnaro, Italy
关键词
LHC; CMS; muon detectors; muon trigger;
D O I
10.1016/j.nima.2006.04.046
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The drift tubes based CMS barrel muon trigger, which uses self-triggering arrays of drift tubes, is able to perform the identification of the ration parent bunch crossing using a rather sophisticated algorithm. The identification is unique only if the trigger chain is correctly synchronized. Some beam test time was devoted to take data useful to investigate the synchronization of the trigger electronics with the machine clock. Possible alternatives were verified and the dependence on muon track properties was studied. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:169 / 177
页数:9
相关论文
共 50 条
  • [1] Fine synchronization of the CMS muon drift-tube local trigger using cosmic rays
    Chatrchyan, S.
    Khachatryan, V.
    Sirunyan, A. M.
    Adam, W.
    Arnold, B.
    Bergauer, H.
    Bergauer, T.
    Dragicevic, M.
    Eichberger, M.
    Eroe, J.
    Friedl, M.
    Fruehwirth, R.
    Ghete, V. M.
    Hammer, J.
    Haensel, S.
    Hoch, M.
    Hoermann, N.
    Hrubec, J.
    Jeitler, M.
    Kasieczka, G.
    Kastner, K.
    Krammer, M.
    Liko, D.
    de Abril, I. Magrans
    Mikulec, I.
    Mittermayr, F.
    Neuherz, B.
    Oberegger, M.
    Padrta, M.
    Pernicka, M.
    Rohringer, H.
    Schmid, S.
    Schoefbeck, R.
    Schreiner, T.
    Stark, R.
    Steininger, H.
    Strauss, J.
    Taurok, A.
    Teischinger, F.
    Themel, T.
    Uhl, D.
    Wagner, P.
    Waltenberger, W.
    Walzel, G.
    Widl, E.
    Wulz, C. -E.
    Chekhovsky, V.
    Dvornikov, O.
    Emeliantchik, I.
    Litomin, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2010, 5
  • [2] Bunched beam test of the CMS drift tubes local muon trigger
    Arce, P
    Bellato, M
    Benettoni, M
    Benvenuti, A
    Bonacorsi, D
    Bontenackels, M
    Caballero, J
    Cafaro, V
    Capiluppi, P
    Castellani, L
    Cavallo, FR
    Cerrada, M
    Checchia, P
    Colino, N
    Conti, E
    Corvo, M
    de la Cruz, B
    Dal Corso, F
    Dallavalle, GM
    De Giorgi, M
    Fabbri, E
    Fanfani, A
    Fernandez, C
    de Trocóniz, JE
    Fouz, MC
    Abia, P
    Gasparini, F
    Gasparini, U
    Giacomelli, P
    Giordano, V
    Gonella, F
    Grandi, C
    Guiducci, L
    Gulmini, M
    Hebbeker, I
    Hernandez, JM
    Hoepfner, K
    Josa, I
    Lacaprara, S
    Lippi, I
    Mameghani, R
    Marcellini, S
    Maron, G
    Martinelli, R
    Maselli, S
    Masetti, G
    Meneguzzo, AT
    Meng, G
    Monaco, V
    Montanari, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 534 (03): : 441 - 485
  • [3] Results of the first integration test of the CMS drift tubes muon trigger
    Aldaya, M.
    Amapane, N.
    Argiro, S.
    Battilana, C.
    Bellan, R.
    Bellato, M.
    Benvenuti, A.
    Boldini, M.
    Bolognesi, S.
    Bontenackels, M.
    Borsato, E.
    Bralbant, S.
    Cafaro, V.
    Capiluppi, P.
    Castellani, L.
    Cavallo, F. R.
    Cerminara, G.
    Cerrada, M.
    Cheechia, P.
    Conti, E.
    de la Cruz, B.
    Dal Corso, F.
    Dallavalle, G. M.
    Deldicque, C.
    Dellacasa, G.
    Eroe, J.
    Fanfani, A.
    Fernandez, C.
    de Troconiz, J. Fernandez
    Fouz, M. C.
    Gasparini, F.
    Gasparini, U.
    Giacomelli, P.
    Giordano, V.
    Giunta, M.
    Gonella, F.
    Guiducci, L.
    Hebbeker, T.
    Hoepfner, K.
    Jimenez, I.
    Josa, I.
    Lacaprara, S.
    Lippi, I.
    Marcellini, S.
    Mariotti, C.
    Maron, G.
    Maselli, S.
    Masetti, G.
    Meneguzzo, A. T.
    Mila, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (03): : 951 - 960
  • [4] A Proposal for the Upgrade of the Muon Drift Tubes Trigger for the CMS Experiment at the HL-LHC
    Pozzobon, Nicola
    Zotto, Pierluigi
    Montecassiano, Fabio
    [J]. CONNECTING THE DOTS 2016, 2016, 127
  • [5] Calibration of the barrel muon drift tubes of CMS
    Mila, Giorgia
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 177 - 179
  • [6] The drift tube track finder muon trigger at the CMS
    Jiménez, I
    [J]. CZECHOSLOVAK JOURNAL OF PHYSICS, 2005, 55 : B819 - B824
  • [7] The Drift Tube Barrel Muon Trigger at the CMS experiment
    de Troconiz, J. F.
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 172 : 171 - 173
  • [8] The CMS muon barrel drift tubes system commissioning
    Abbiendi, G.
    Amapane, N.
    Battilana, C.
    Fernandez Bedoya, C.
    Bellan, R.
    Bellato, M.
    Benvenuti, A. C.
    Biallas, P.
    Bolognesi, S.
    Braibant, S.
    Cavallo, F. R.
    Carlin, R.
    Cerminara, G.
    Chamizo, M.
    Conti, E.
    Dallavalle, G. M.
    Dattola, D.
    Dellacasa, G.
    Fouz, M. C.
    Frangenheim, J.
    Giacomelli, P.
    Giunta, M.
    Gonella, F.
    Gresele, A.
    Guiducci, L.
    Hoepfner, K.
    Jacobi, E.
    Marcellini, S.
    Mariotti, C.
    Maselli, S.
    Masetti, G.
    Meneguzzo, A. T.
    Mila, G.
    Monaco, V.
    Montanari, A.
    Montecassiano, F.
    Navarria, F. L.
    Nervo, M.
    Odorici, F.
    Passaseo, M.
    Parenti, A.
    Perrotta, A.
    Puerta, J.
    Reithler, H.
    Ronchese, P.
    Rovelli, T.
    Sacchi, R.
    Siroli, G. P.
    Sowa, M.
    Staiano, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 192 - 195
  • [9] Calibration of the Barrel Muon Drift Tubes System in CMS
    Maselli, Silvia
    [J]. 17TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP09), 2010, 219
  • [10] The drift tubes of the barrel-muon detector of CMS
    Gasparini, F
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 384 (01): : 211 - 213