Fabrication of a novel enzymatic electrochemical biosensor for determination of tyrosine in some food samples

被引:58
|
作者
Varmira, Kambiz [1 ]
Mohammadi, Ghobad [2 ]
Mahmoudi, Majid [1 ]
Khodarahmi, Reza [3 ]
Rashidi, Khodabakhsh [1 ]
Hedayati, Mehdi [4 ]
Goicoechea, Hector C. [5 ]
Jalalvand, Ali R. [1 ]
机构
[1] Kermanshah Univ Med Sci, FDA, RCOF, Kermanshah, Iran
[2] Kermanshah Univ Med Sci, Sch Pharm, Dept Pharmaceut, Kermanshah, Iran
[3] Kermanshah Univ Med Sci, Med Biol Res Ctr, Kermanshah, Iran
[4] Shahid Beheshti Univ Med Sci, Res Inst Endocrine Sci, Cellular & Mol Endocrine Res Ctr, Tehran, Iran
[5] Univ Nacl Litoral, Catedra Quim Analit 1, Lab Desarrollo Analit & Quimiometria LADAQ, Ciudad Univ,CC 242,S3000ZAA, Santa Fe, Argentina
关键词
Tyrosine; Tyrosine hydroxylase; Levodopa; Biosensor; High tyrosine foods; GLASSY-CARBON ELECTRODE; ALLOY NANOPARTICLES; VOLTAMMETRIC DETERMINATION; COMPOSITE FILM; AMINO-ACIDS; SENSOR; CYCLODEXTRIN; RECOGNITION; TRYPTOPHAN; BEHAVIOR;
D O I
10.1016/j.talanta.2018.02.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, fabrication of a novel and ultrasensitive electrochemical biosensor based on immobilization of tyrosine hydroxylase onto palladium-platinum bimetallic alloy nanoparticles/chitosan-1-ethyl-3-methylimidazoliurn bis(trifluoromethylsulfonyl) imide/graphene-multiwalled carbon nanotubes-IL/glassy carbon electrode for determination of L-tyrosine in some high tyrosine foods including cheese, egg and yogurt was reported. Immobilization of tyrosine hydroxylase onto the surface of the biosensor was performed by cross-linking tyrosine hydroxylase and chitosan through the addition of glutaraldehyde. Enzymatic biosensors employ the affinity and selectivity of catalytically active proteins towards their target molecules and here, the tyrosine hydroxylase selectively catalyzes the conversion of tyrosine to levodopa which can be oxidized at lower potentials than tyrosine. The modifications were characterized by electrochemical impedance spectroscopy, cyclic voltammetry, energy dispersive X-ray spectroscopic and scanning electron microscopy. Under optimal conditions, the biosensor detected tyrosine in concentration ranges of 0.01 x 10(-9) to 8.0 x 10(-9) mol L-1 and 8.0 x 10(-9) to 160.0 x 10(-9) mol L-1 with a limit of detection of 0.009 x 10(-9) mol L-1. The biosensor was able to selective determination of tyrosine even in the presence of common interferents therefore, the biosensor was highly selective. The biosensor also showed good operational stability, antifouling properties, sensitivity, repeatability and reproducibility.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [1] Direct determination of nitrite in food samples by electrochemical biosensor
    Mesaros, S
    Brunova, A
    Mesarosova, A
    CHEMICAL PAPERS, 1998, 52 (03) : 156 - 158
  • [2] Fabrication of an electrochemical biosensor with ZnO nanoflakes interface for methylglyoxal quantification in food samples
    Jayaprakasan, Amudha
    Thangavel, Amarnath
    Bhat, Lakshmishri Ramachandra
    Gumpu, Manju Bhargavi
    Nesakumar, Noel
    Babu, K. Jayanth
    Vedantham, Srinivasan
    Rayappan, John Bosco Balaguru
    FOOD SCIENCE AND BIOTECHNOLOGY, 2018, 27 (01) : 9 - 17
  • [3] Fabrication of an electrochemical biosensor with ZnO nanoflakes interface for methylglyoxal quantification in food samples
    Amudha Jayaprakasan
    Amarnath Thangavel
    Lakshmishri Ramachandra Bhat
    Manju Bhargavi Gumpu
    Noel Nesakumar
    K. Jayanth Babu
    Srinivasan Vedantham
    John Bosco Balaguru Rayappan
    Food Science and Biotechnology, 2018, 27 : 9 - 17
  • [4] A Novel Electrochemical Biosensor Design and Fabrication
    Basheer, E.
    Bari, H.
    Chin, C. E.
    Nudra, S.
    JOURNAL OF PURE AND APPLIED MICROBIOLOGY, 2015, 9 : 525 - 532
  • [5] Intellectual modifying a bare glassy carbon electrode to fabricate a novel and ultrasensitive electrochemical biosensor: Application to determination of acrylamide in food samples
    Varmira, Kambiz
    Abdi, Omid
    Gholivand, Mohammad-Bagher
    Goicoechea, Hector C.
    Jalalvand, Ali R.
    TALANTA, 2018, 176 : 509 - 517
  • [6] Fabrication of Biosensor for Selective Electrochemical Determination of Glycated Hemoglobin
    Li, Min
    Zhao, Wenjie
    Tian, Linlin
    Li, Huafeng
    Fan, Bo
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (09): : 8411 - 8420
  • [7] Fabrication of novel electrochemical sensor for determination of vitamin C in the presence of vitamin B9 in food and pharmaceutical samples
    Khaleghi, Fatemeh
    Arab, Zahra
    Gupta, Vinod Kumar
    Ganjali, M. R.
    Norouzi, Parviz
    Atar, Necip
    Yola, Mehmet L.
    JOURNAL OF MOLECULAR LIQUIDS, 2016, 221 : 666 - 672
  • [8] Fabrication of a Novel Electrochemical Sensor for Determination of Riboflavin in Different Drink Real Samples
    Derakhshan, M.
    Shamspur, T.
    Molaakbari, E.
    Mostafavi, A.
    Saljooqi, A.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2020, 56 (03) : 181 - 188
  • [9] Fabrication of a Novel Electrochemical Sensor for Determination of Riboflavin in Different Drink Real Samples
    M. Derakhshan
    T. Shamspur
    E. Molaakbari
    A. Mostafavi
    A. Saljooqi
    Russian Journal of Electrochemistry, 2020, 56 : 181 - 188
  • [10] Biotin determination in food supplements by an electrochemical magneto biosensor
    Kergaravat, Silvina V.
    Gomez, Gabriel A.
    Fabiano, Silvia N.
    Laube Chavez, Tamara I.
    Pividori, Maria I.
    Hernandez, Silvia R.
    TALANTA, 2012, 97 : 484 - 490