Discussion on infrared accurate temperature-measuring technology of composite insulators for overhead lines

被引:8
|
作者
Liu, Rong [1 ]
Shen, Qinghe [1 ]
Liu, Hui [1 ]
Duan, Yubing [1 ]
Zhang, Yang [1 ]
Zhou, Chao [1 ]
机构
[1] State Grid China, State Grid Shandong Elect Power Res Inst, Jinan, Shandong, Peoples R China
来源
关键词
infrared imaging; power overhead lines; temperature measurement; composite insulators; overhead lines; actual operation state; atmospheric environment; detection requirements; infrared accurate temperature-measuring technology; detection environment; local detection; insulation deterioration; infrared temperature measurement data;
D O I
10.1049/joe.2018.8425
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Through analysing the infrared temperature measurement data obtained from composite insulators for overhead lines in actual operation state and atmospheric environment, detection requirements of infrared accurate temperature-measuring technology of composite insulators for overhead lines were discussed, such as the detector, detection environment, and position. According to the local detection, two kinds of insulators' local heating, caused by insulation deterioration and damp contamination on the surface, were researched. A judgment method was proposed, and overheat of the electric equipment, which was caused by voltage effect, should be judged from both the contrast of similar equipment and the thermal image characteristic. This method can greatly reduce the insulators overheat error rate, improve the detection efficiency of composite insulators, and enhance the accuracy of composite insulators' insulation defects judgment.
引用
收藏
页码:1759 / 1762
页数:4
相关论文
共 28 条
  • [1] Development of composite insulators for overhead lines (Part 2)
    Kobayashi, Satoshi
    Matsuzaki, Yutaka
    Arashitani, Yoshihiro
    Kimata, Ryuzo
    Furukawa Review, 2002, (21): : 56 - 61
  • [2] Effect of are current on properties of composite insulators for overhead lines
    Mazurek, B
    Maczka, T
    Gmitrzak, A
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 802 - 805
  • [3] Measuring the radiation bands of overhead power lines glass insulators
    Rocha, Pedro H. V.
    Fontgalland, Glauco
    2014 IEEE CONFERENCE ON ANTENNA MEASUREMENTS & APPLICATIONS (CAMA), 2014,
  • [4] Study of power frequency arc of composite insulators for overhead lines
    Wu, Guangya
    Lin, Xiuqin
    Cai, Wei
    Zhang, Rui
    Xiao, Guoying
    Gu, Guanghe
    Gaodianya Jishu/High Voltage Engineering, 2002, 28 (11):
  • [5] Plastic Composite Insulators for High-Voltage Overhead Lines.
    Pargamin, Laurent
    Huc, Jean
    Elektrizitatswirtschaft, 1980, 79 (08): : 290 - 293
  • [6] Implementation of Temperature-Measuring System Based on ZigBee Technology The Technology research on Sensor Network
    Wang Zizhen
    2017 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND ENGINEERING (CSE) AND IEEE/IFIP INTERNATIONAL CONFERENCE ON EMBEDDED AND UBIQUITOUS COMPUTING (EUC), VOL 1, 2017, : 668 - 672
  • [7] Study of dielectric properties of composite insulators for use in medium voltage overhead lines
    Mandhi, Noureddine
    Askri, Besma
    Raouadi, Khaled
    Damamme, Gilles
    Dakhli, Radhouan
    JOURNAL OF ELECTROSTATICS, 2013, 71 (05) : 892 - 897
  • [8] FIELD EXPERIENCE AND LABORATORY AGEING TESTS ON COMPOSITE INSULATORS FOR OVERHEAD LINES.
    Fini, G.P.
    Marrone, G.
    Gallucci, F.
    Pigini, A.
    Energia Elettrica, 1984, 61 (7-8): : 310 - 320
  • [9] Accurate measuring temperature with infrared thermal imager
    Li, Yun-Hong
    Sun, Xiao-Gang
    Yuan, Gui-Bin
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2007, 15 (09): : 1336 - 1341
  • [10] Finite element analysis of composite structure continuous temperature-measuring sensor for liquid steel
    Zhao, Shu-Mao
    Mei, Guo-Hui
    Zhang, Jiu
    Xie, Zhi
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2012, 33 (07): : 926 - 929